José Luis Ausín has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated gm/ID Co-Design Framework for Wideband Instrumentation Amplifiers in Wearable Bioimpedance Spectroscopy

    by Francisco R. Morillo-Velarde, Javier Ramos, José L. Ausin

    Wearable bioimpedance spectroscopy within Internet of Medical Things ecosystems requires energy-efficient analog front-ends (AFEs) capable of processing small impedance-dependent signals over a wide excitation-frequency range. This paper presents a preliminary study of an automated gm/ID-based framework for the co-design of wideband CMOS instrumentation amplifiers, jointly considering power, noise, bandwidth, and frequency-dependent common-mode rejection. The proposed flow combines technology-characterized device data, Verilog-A behavioral modeling, Python-based optimization, and SKILL-assisted transistor-level verification. The methodology is applied to a wideband CMOS current-feedback instrumentation amplifier (CFIA) designed in a 180-nm CMOS technology. Operating from a 1.8-V supply, the amplifier provides a nominal gain of 30 V/V over the 1-kHz to 2-MHz signal band. Particular attention is given to the coupling between transistor sizing, parasitic capacitance, and high-frequency CMRR in a local current-feedback topology. The paper establishes the BIS readout requirements, describes the selected CFIA architecture, and formulates the main design variables and optimization targets. The presented results constitute the initial stage of a broader design framework; complete optimization, statistical robustness, and experimental validation are reserved for the subsequent full study.

  • Open Access

    Programmable CMOS current signal generator for simultaneous multi-sine bioimpedance analysis

    by Israel Corbacho, Juan M. Carrillo, José L. Ausín, Miguel Á. Domínguez, Raquel Pérez-Aloe, J. Francisco Duque-Carrillo


  • A 4-Decade-Tunable High-Selectivity Gm -C Bandpass Filter for Simultaneous Multi-Sine Bioimpedance Analysis

    by Israel Corbacho, Juan M. Carrillo, José L. Ausín, Miguel Á. Domínguez, Raquel Peréz-Aloe, J. Francisco Duque-Carrillo

    A bandpass filter (BPF), with high quality factor ( Q ) and wide tuning range of the centre frequency ( $f_0$ ), for signal separation in simultaneous multi-sine bioimpedance analysis, is presented. The cell follows the $G_m$ - C approach, where a multiple-output transconductor has been incorporated, for the sake of compactness, and a fully-differential structure has been selected, to enhance the general performance of the solution. The linearized transconductors ( $G_m$ ) are based on a double asymmetric differential pair and the integrated capacitors ( C ) are implemented in such a way that the required transfer function for the differential-mode signal is achieved and the stability of the common-mode component is granted. The BPF has been designed and fabricated in 180 nm CMOS technology to operate with a 1.8-V supply and feature a nominal gain at $f_0$ of 0 dB and a Q equal to 20, whereas $f_0$ is programmed by modifying the biasing current of the transconductors. Experimental results, measured on 8 samples of the silicon prototype, show that the BPF centre frequency can be continuously swept from 102 Hz to 2.06 MHz with a supply current ranging between 981 nA and 686 $\mu$ A. Besides, the maximum output voltage range of the filter, determined according to the –40 dB THD criterion, varies between around 31.5 mV and 64 mV within the frequency range indicated, thus leading to a dynamic range between 42.3 dB and 48.6 dB, which illustrates its suitability for the target application.


  • Open Access

    Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm

    by José L. Ausín, Javier Ramos, Antonio Lorido, Pedro Molina, J. Francisco Duque-Carrillo

    Noninvasive remote monitoring of hemodynamic variables is essential in optimizing treatment opportunities and predicting rehospitalization in patients with congestive heart failure. The objective of this study is to develop a wearable bioimpedance-based device, which can provide continuous measurement of cardiac output and stroke volume, as well as other physiological parameters for a greater prognosis and prevention of congestive heart failure. The bioimpedance system, which is based on a robust and cost-effective measuring principle, was implemented in a CMOS application specific integrated circuit, and operates as the analog front-end of the device, which has been provided with a radio-frequency section for wireless communication. The operating parameters of the proposed wearable device are remotely configured through a graphical user interface to measure the magnitude and the phase of complex impedances over a bandwidth of 1 kHz to 1 MHz. As a result of this study, a cardiac activity monitor was implemented, and its accuracy was evaluated in 33 patients with different heart diseases, ages, and genders. The proposed device was compared with a well-established technique such as Doppler echocardiography, and the results showed that the two instruments are clinically equivalent.


  • Low-Gm CMOS Transconductors with Wide Tuning Range for Bioimpedance Spectroscopy

    by Israel Corbacho, Juan M. Carrillo, José L. Ausín, Miguel Á. Domínguez, Raquel Pérez-Aloe, J. Francisco Duque-Carrillo

    Two techniques to design a low-transconductance (G m ) widely-tunable transconductor are described. The operation principle consists in both cases in the subtraction of two nominally equal transconductances, one of which can be electronically tuned. The circuit implementation differs, being one solution based on the use of source followers (SF), a linearization resistor, and a tunable current mirror, and consisting the other approach of differential pairs (DP) with resistive source degeneration, and an electronically programmable current biasing. Both transconductors have been designed in 180 nm CMOS technology to operate with 1.8 V. The SF and DP solutions achieve a minimum G m nominal value of 1.38 nA/V and 6.03 nA/V, respectively, with a simulated transconductance tuning range of 729.6× and 7129.4×, also respectively, obtained from a Montecarlo analysis. The application of the transconductors to the design of a second-order G m − C bandpass filter for signals separation in multi-sine bioimpedance spectroscopy is also addressed.

  • Open Access

    CMOS Widely Tunable Second-Order Gm-C Bandpass Filter for Multi-Sine Bioimpedance Analysis

    by Israel Corbacho, Juan M. Carrillo, José L. Ausín, Miguel Á. Domínguez, Raquel Pérez-Aloe, J. Francisco Duque-Carrillo

    A CMOS widely tunable second-order Gm-C bandpass filter (BPF), intended to be used in multi-sine bioimpedance applications, is presented. The filter incorporates a tunable transconductor in which the responses of two linearized voltage-to-current converters are subtracted. As a result, the effective transconductance can be continuously adjusted over nearly three decades, which allows a corresponding programmability of the center frequency of the BPF. The circuit was designed and fabricated in 180 nm CMOS technology to operate with a 1.8 V supply, and the experimental characterization was carried out over eight samples of the silicon prototype. The simulated transconductance of the cell can be tuned from 5.3 nA/V up to 19.60 μA/V. The measured range of the experimental transconductance varied, however, between 1.42 μA/V and 20.57 μA/V. Similarly, the center frequency of the BPF, which in the simulations ranged from 500 Hz to 342 kHz, can be programmed in the silicon prototypes from 22.4 kHz to 290 kHz. Monte Carlo and corner simulations were carried out to ascertain the origin of this deviation. Besides, the extensive simulation and experimental characterization of the standalone transconductor and the complete BPF are provided.


  • RECONFIGURABLE PROTOTYPE FOR THE EXPERIMENTAL CHARACTERIZATION OF OPERATIONAL AMPLIFIERS IN ELECTRONICS LABS

    by Álvaro Gómez-Márquez, Juan Manuel Carrillo, Miguel Ángel Domínguez, Raquel Pérez-Aloe, José Luis Ausín, Juan Francisco Duque-Carrillo

  • INTEGRATION OF INSTRUMENTATION EQUIPMENT IN A REMOTE ELECTRONICS LABORATORY

    by Miguel Ángel Domínguez, Raquel Pérez-Aloe, Juan Manuel Carrillo, José Luis Ausín, Juan Francisco Duque-Carrillo


  • Open Access

    A Fully-Differential CMOS Instrumentation Amplifier for Bioimpedance-Based IoT Medical Devices

    by Israel Corbacho, Juan M. Carrillo, José L. Ausín, Miguel Á. Domínguez, Raquel Pérez-Aloe, J. Francisco Duque-Carrillo

    The implementation of a fully-differential (FD) instrumentation amplifier (IA), based on indirect current feedback (ICF) and aimed to electrical impedance measurements in an Internet of Things (IoT) biomedical scenario, is presented. The IA consists of two FD transconductors, to process the input signal and feed back the output signal, a summing stage, used to add both contributions and generate the correcting current feedback signal, and a common-mode feedback network, which controls the DC level at the output nodes of the circuit. The transconductors are formed by a voltage-to-current conversion resistor and two voltage buffers, which are based on a super source follower cell in order to improve the overall response of the circuit. As a result, a compact single-stage structure, suitable for achieving a high bandwidth and a low power consumption, is obtained. The FD ICF IA has been designed and fabricated in 180 nm CMOS technology to operate with a 1.8-V supply and provide a nominal gain of 4 V/V. Experimental results show a voltage gain of 3.78 ± 0.06 V/V, a BW of 5.83 MHz, a CMRR at DC around 70 dB, a DC current consumption of 266.4 μA and a silicon area occupation of 0.0304 mm2.


  • Open Access

    Wide-Bandwidth Electronically Programmable CMOS Instrumentation Amplifier for Bioimpedance Spectroscopy

    by Israel Corbacho, Juan M. Carrillo, Jose L. Ausin, Miguel A. Dominguez, Raquel Perez-Aloe, J. Francisco Duque-Carrillo

    An instrumentation amplifier (IA) with continuous tuning of the voltage gain, suitable for operation over a wide frequency range, and aimed to electrical bioimpedance spectroscopy, is proposed. The operation principle of the IA is based on indirect current feedback (ICF), which leads to an almost-constant bandwidth regardless of the value of the programmed voltage gain. The use of improved voltage followers in the transconductors required in the ICF technique allows achieving a compact implementation with a bandwidth compatible with bioimpedance spectroscopy applications. The tuning strategy relies on a continuously programmable current mirror that can be electronically adjusted by means of a control current. The IA has been designed and fabricated in 180 nm CMOS technology to operate with a 1.8-V single supply. The experimental characterization of the silicon prototypes showed a gain programmability range higher than 45 dB, between −4.6 dB and 41.2 dB, a BW around 3 MHz, and a maximum CMRR at DC higher than 86 dB, all this with a minimum current consumption of $144.8~\mu \text{A}$ and an area occupation of 0.0196 mm2.