Simultaneous Monitoring of Particle-Bound PAHs Inside a Low-Energy School Building and Outdoors over Two Weeks in France
Open Access
- 13 January 2021
- journal article
- research article
- Published by MDPI AG in Atmosphere
- Vol. 12 (1) , 108
Abstract
The emergence of new super-insulated buildings to reduce energy consumption can lead to a degradation of the indoor air quality. While some studies were carried out to assess the air quality in these super-insulated buildings, they were usually focused on the measurement of gas phase pollutants such as carbon dioxide and volatile organic compounds. This work reports the first measurements of Polycyclic Aromatic Hydrocarbons (PAHs) associated with particles as a function of time and particle size in a low-energy building. The airborne particles were collected indoors and outdoors over three to four days of sampling using two three-stage cascade impactors allowing to sample simultaneously particles with aerodynamic diameter Dae > 10 µm, 2.5 µm < Dae < 10 µm, 1 µm < Dae < 2.5 µm, and Dae < 1 µm. The 16 US-EPA priority PAHs were then extracted and quantified by high-performance liquid chromatography (HPLC) coupled to fluorescence detection. The resulting total particle concentrations were low, in the ranges 3.73 to 9.66 and 0.60 to 8.83 µg m-3 for indoors and outdoors, respectively. Thirteen PAHs were always detected in all the samples. The total PAH concentrations varied between 290 and 415 pg m−3 depending on the particle size, the environment (indoors or outdoors) and the sampling period considered. More interestingly, the temporal variations of individual PAHs highlighted that high molecular weight PAHs were mainly associated to the finest particles and some of them exhibited similar temporal behaviors, suggesting a common emission source. The indoor-to-outdoor concentration ratios of individual PAH were usually found close to or less than 1, except during the event combining rainy conditions and limited indoor ventilation rate.Keywords
Funding Information
- Agence de l'Environnement et de la Maîtrise de l'Energie (1262C0023)
This publication has 46 references indexed in Scilit:
- Near Real-Time Monitoring of Formaldehyde in a Low-Energy School BuildingAtmosphere, 2019
- Impact of material emissions and sorption of volatile organic compounds on indoor air quality in a low energy building: Field measurements and modelingIndoor Air, 2018
- Portable novel micro-device for BTEX real-time monitoring: Assessment during a field campaign in a low consumption energy junior high school classroomAtmospheric Environment, 2016
- Investigation of indoor and outdoor air quality of the classrooms at a school in SerbiaEnergy, 2014
- Indoor PAHs at schools, homes and offices in Rome, ItalyAtmospheric Environment, 2014
- Characterization of particulate and vapor phase polycyclic aromatic hydrocarbons in indoor and outdoor air of primary schoolsAtmospheric Environment, 2014
- Providing better thermal and air quality conditions in school classrooms would be cost-effectiveBuilding and Environment, 2013
- Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in EnglandBuilding and Environment, 2009
- Improving energy performance of school buildings while ensuring indoor air quality ventilationBuilding and Environment, 2007
- Potential reactions among indoor pollutantsAtmospheric Environment, 1997