Abstract
The aim of the study was to conduct a hydrodynamic assessment of the efficiency of heart valve prostheses made of xenopericardium protected by polyvinyl alcohol.Materials and methods. Experimental prostheses based on the UniLine bioprosthesis model were manufactured for the study. The xenopericardium used for the valve cusps was modified with polyvinyl alcohol to improve its resistance to biological and mechanical effects. Hydrodynamic tests were performed on a Pulse Duplicator system, which simulates the function of the “left heart”. The key parameters of the prosthesis operation were estimated including average transprosthetic gradient, effective orifice area, locking volume, and regurgitant volume. Unmodified prostheses of similar size were used as a control.Results. Hydrodynamic tests showed that the experimental prostheses demonstrate an increase in the average transprosthetic gradient to 6.59 mm Hg. (compared to 5.29 mm Hg in the control group) and a decrease in the effective orifice area to 1.52 cm² (1.69 cm² in the control group). The regurgitant volume also increased to 23.3 ml per cycle, which is higher than the control value of 12.2 ml per cycle. Despite this, all indicators remain within the permissible values established by the state standard (GOST).Conclusion. The use of polyvinyl alcohol to protect the xenopericardium demonstrates potential advantages such as increased resistance of the material to biological effects, but is accompanied by some decrease in the hydrodynamics of the prosthesis. Nevertheless, the efficiency indicators remain within the standards, which opens up opportunities for further improvement of the technology. It is necessary to continue research in order to optimize the material and design to improve both the biocompatibility and functional characteristics of the prosthesis.Keywords
This publication has 16 references indexed in Scilit:
- Cytotoxicity of Xenogeneic Pericardium Preserved by Epoxy Cross-Linking AgentsSovremennye tehnologii v medicine, 2021
- Polymeric valves appearing on the transcatheter horizonEuropean Journal of Cardio-Thoracic Surgery, 2021
- Design, development, testing at ISO standards and in vivo feasibility study of a novel polymeric heart valve prosthesisBiomaterials Science, 2020
- Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart AssociationCirculation, 2020
- Materials and manufacturing perspectives in engineering heart valves: a reviewMaterials Today Bio, 2020
- Novel Polymeric Valve for Transcatheter Aortic Valve Replacement Applications: In Vitro Hemodynamic StudyAnnals of Biomedical Engineering, 2018
- A NEWLY DEVELOPED TRI-LEAFLET POLYMERIC HEART VALVE PROSTHESISJournal of Mechanics in Medicine and Biology, 2015
- Toward Optimization of a Novel Trileaflet Polymeric Prosthetic Heart Valve via Device Thrombogenicity EmulationASAIO Journal, 2013
- Prosthetic aortic heart valves: Modeling and designMedical Engineering & Physics, 2010
- Hydrodynamic performance of heart valve prostheses: Open discussion on European Committee for Standardization International Organization for Standardization standard 5840The Journal of Thoracic and Cardiovascular Surgery, 2010