Pavel Onishchenko
Research Subjects
Pavel Onishchenko has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Evgeniy A. Ovcharenko
Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo, Russia
32 shared publications - Kirill Yu. Klyshnikov
Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo, Russia
31 shared publications - Alexsander E. Kostyunin
Department of Experimental Medicine, Research Institute for Complex Issues of Cardiovascular Diseases, 650002 Kemerovo, Russia
21 shared publications - Tatiana Vladimirovna Glushkova
Department of Experimental Medicine, Research Institute for Complex Issues of Cardiovascular Diseases, 650002 Kemerovo, Russia
21 shared publications - Tatyana N. Akentyeva
Federal State Budgetary Institution “Research Institute for Complex Issues of Cardiovascular Diseases
17 shared publications - Maria A. Rezvova
Research Institute for Complex Issues of Cardiovascular Diseases
12 shared publications
Latest Publications
- Open Access
- 31 October 2026
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 15 (5) , 207-214
HYDRODYNAMIC CHARACTERISTICS OF UNILINE BIOPROSTHESES IN VARIOUS MODES
Highlights The study provides the first extended in vitro assessment of UniLine bioprostheses across six standardized pressure modes: from hypotension to very severe hypertension, establishing reference hydrodynamic values for domestic heart valve technologies. The bioprostheses demonstrated high stability of essential performance metrics (effective orifice area 1.45–1.53 cm²; mean gradient 4.23–4.38 mmHg) under increasing hemodynamic loads, confirming the adequacy of their structural design and reliability across a broad spectrum of simulated clinical conditions. Regurgitation values under extreme loading revealed intrinsic variability of biological tissues, highlighting the need to account for biomechanical heterogeneity in future engineering optimization and comparative evaluation of domestic bioprosthetic Aim. To evaluate the hydrodynamic performance of the domestic atrioventricular bioprosthesis UniLine (size 26 mm) under multiple loading modes defined by GOST 31618.1-2012. Methods. Twelve prostheses were tested in vitro using the Pulse Duplicator II across six pressure modes: from hypotensive (60/40 mmHg) to very severe hypertension (210/120 mmHg). Heart rate was set at 70 bpm with 35% systolic duration. Three metrics were assessed: mean transvalvular gradient, effective orifice area, and regurgitant volume. Data are presented as median [25 th ; 75 th percentile]. Results . Effective orifice area remained stable across modes (1.45–1.53 cm²; range 1.39–1.81 cm²). Mean gradient remained low, from 4.23 mmHg in hypotension to 4.32–4.38 mmHg in severe/very severe hypertension (overall range 1.55–6.03 mmHg). Regurgitant volume increased with pressure load, from 2.66 to 4.09 mL/cycle (maximum 8.04 mL/cycle in individual tests). All parameters met GOST and ISO requirements. Conclusion . UniLine bioprostheses demonstrate stable hydrodynamic behavior across a broad range of loading conditions, characterized by low gradients, consistent effective orifice area, and acceptable regurgitation. These results provide reference values supporting further optimization and extended preclinical evaluation.
- 31 October 2026
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 15 (5) , 207-214
Open AccessHYDRODYNAMIC CHARACTERISTICS OF UNILINE BIOPROSTHESES IN VARIOUS MODES
Highlights The study provides the first extended in vitro assessment of UniLine bioprostheses across six standardized pressure modes: from hypotension to very severe hypertension, establishing reference hydrodynamic values for domestic heart valve technologies. The bioprostheses demonstrated high stability of essential performance metrics (effective orifice area 1.45–1.53 cm²; mean gradient 4.23–4.38 mmHg) under increasing hemodynamic loads, confirming the adequacy of their structural design and reliability across a broad spectrum of simulated clinical conditions. Regurgitation values under extreme loading revealed intrinsic variability of biological tissues, highlighting the need to account for biomechanical heterogeneity in future engineering optimization and comparative evaluation of domestic bioprosthetic Aim. To evaluate the hydrodynamic performance of the domestic atrioventricular bioprosthesis UniLine (size 26 mm) under multiple loading modes defined by GOST 31618.1-2012. Methods. Twelve prostheses were tested in vitro using the Pulse Duplicator II across six pressure modes: from hypotensive (60/40 mmHg) to very severe hypertension (210/120 mmHg). Heart rate was set at 70 bpm with 35% systolic duration. Three metrics were assessed: mean transvalvular gradient, effective orifice area, and regurgitant volume. Data are presented as median [25 th ; 75 th percentile]. Results . Effective orifice area remained stable across modes (1.45–1.53 cm²; range 1.39–1.81 cm²). Mean gradient remained low, from 4.23 mmHg in hypotension to 4.32–4.38 mmHg in severe/very severe hypertension (overall range 1.55–6.03 mmHg). Regurgitant volume increased with pressure load, from 2.66 to 4.09 mL/cycle (maximum 8.04 mL/cycle in individual tests). All parameters met GOST and ISO requirements. Conclusion . UniLine bioprostheses demonstrate stable hydrodynamic behavior across a broad range of loading conditions, characterized by low gradients, consistent effective orifice area, and acceptable regurgitation. These results provide reference values supporting further optimization and extended preclinical evaluation.
- Open Access
- 4 September 2026
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 15 (4) , 185-195
MODELING THE DESIGN OF THE EXPANDABLE HEART VALVE PROSTHESIS
MODELING THE DESIGN OF THE EXPANDABLE HEART VALVE PROSTHESIS | Klyshnikov | Complex Issues of Cardiovascular Diseases МОДЕЛИРОВАНИЕ КОНСТРУКЦИИ РАЗДВИЖНОГО ПРОТЕЗА КЛАПАНА СЕРДЦА | Клышников | Комплексные проблемы сердечно-сосудистых заболеваний
- 4 September 2026
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 15 (4) , 185-195
Open AccessMODELING THE DESIGN OF THE EXPANDABLE HEART VALVE PROSTHESIS
MODELING THE DESIGN OF THE EXPANDABLE HEART VALVE PROSTHESIS | Klyshnikov | Complex Issues of Cardiovascular Diseases МОДЕЛИРОВАНИЕ КОНСТРУКЦИИ РАЗДВИЖНОГО ПРОТЕЗА КЛАПАНА СЕРДЦА | Клышников | Комплексные проблемы сердечно-сосудистых заболеваний
- 30 June 2026
- Published by PNRPU Publishing House in Russian Journal of Biomechanics
- Vol. 30 (2) , 41-50
Automated workflow for parametric model generation and finite-element assessment of crimping: a case study of a transcatheter heart valve prosthesis frame
In recent years, transcatheter heart valve prostheses have become increasingly relevant due to lower surgical risks, relative ease of implantation, and faster recovery times compared to open-heart surgery. The steady growth in the number of such procedures in Russian Federation necessitates the development of new tools for designing prosthetic valve frames. This study aims to develop an algorithmic method for generating parameterized models of transcatheter prosthetic frames, followed by a numerical evaluation of their crimping process. The proposed approach comprises three automated modules that form the basis of an optimization workflow: a parametric model “Generator”, a “Numerical Analysis” of crimping, and an automated “Evaluation” of results. To implement this, an algorithm was developed using Python with the CadQuery package for geometry generation and integration with the Abaqus/CAE finite element analysis software. Distinct from existing research in this field, the key novelty of this work lies in the ability to generate new types of transcatheter heart valve support frames based solely on the constraints of the predefined unit cell shape. The study examined 1,225 unique designs, evaluated based on von Mises stress (S, MPa), reaction force (RF, N), and elastic recoil. Among the evaluated geometries, 36 designs demonstrated the capability to be crimped to the target diameter. Furthermore, a comparison of two results with similar frame lengths and stress levels (S) revealed a significant difference in RF upon reaching 6 mm (1374.198 N vs. 284.240 N). The presented approach establishes a foundation for further frame optimization using genetic algorithms or Bayesian optimizers, enhancing the potential for creating next-generation domestic medical devices.
- 30 June 2026
- Published by PNRPU Publishing House in Russian Journal of Biomechanics
- Vol. 30 (2) , 41-50
Automated workflow for parametric model generation and finite-element assessment of crimping: a case study of a transcatheter heart valve prosthesis frame
In recent years, transcatheter heart valve prostheses have become increasingly relevant due to lower surgical risks, relative ease of implantation, and faster recovery times compared to open-heart surgery. The steady growth in the number of such procedures in Russian Federation necessitates the development of new tools for designing prosthetic valve frames. This study aims to develop an algorithmic method for generating parameterized models of transcatheter prosthetic frames, followed by a numerical evaluation of their crimping process. The proposed approach comprises three automated modules that form the basis of an optimization workflow: a parametric model “Generator”, a “Numerical Analysis” of crimping, and an automated “Evaluation” of results. To implement this, an algorithm was developed using Python with the CadQuery package for geometry generation and integration with the Abaqus/CAE finite element analysis software. Distinct from existing research in this field, the key novelty of this work lies in the ability to generate new types of transcatheter heart valve support frames based solely on the constraints of the predefined unit cell shape. The study examined 1,225 unique designs, evaluated based on von Mises stress (S, MPa), reaction force (RF, N), and elastic recoil. Among the evaluated geometries, 36 designs demonstrated the capability to be crimped to the target diameter. Furthermore, a comparison of two results with similar frame lengths and stress levels (S) revealed a significant difference in RF upon reaching 6 mm (1374.198 N vs. 284.240 N). The presented approach establishes a foundation for further frame optimization using genetic algorithms or Bayesian optimizers, enhancing the potential for creating next-generation domestic medical devices.
- 30 June 2026
- Published by PNRPU Publishing House in Российский журнал биомеханики
- Vol. 30 (2) , 50-59
Автоматизированный подход к параметрической генерации модели и мкэ-оценке процесса ее сжатия: пример каркаса транскатетерного протеза клапана сердца
В последние годы транскатетерные протезы клапанов сердца становятся все более востребованными из-за меньших рисков, относительной простоты имплантации и более быстрого восстановления по сравнению с открытыми операциями. Постоянный рост числа таких вмешательств в России требует разработки новых инструментов проектирования каркасов протезов. Цель исследования – разработать алгоритмический метод генерации параметризированных моделей каркасов транскатетерных протезов с последующей численной оценкой процесса их сжатия. Созданный подход включает в себя три блока, работающие в автоматическом режиме, что является основой для построения оптимизационного процесса: «Генератор» параметрических моделей, «Численный анализ» сжатия и автоматическая «Оценка» результатов. Для ее решения разработан алгоритм, реализованный на Python с использованием пакета CadQuery для создания геометрии и интеграции с программой численного анализа методом конечных элементов Abaqus/CAE. В отличие от существующих работ в данной тематике, важнейшим критерием новизны описанного материала является возможность разработки новых видов опорных каркасов транскатетерных протезов клапанов сердца на основе ограниченного только формой заложенной элементарной ячейки. В исследовании рассмотрено 1225 уникальных дизайнов, оцененных по критериям напряжения по Мизесу (S, МПа), силы реакции опоры (RF, Н) и величины эластической отдачи. Из полученных результатов 36 дизайнов показали возможность быть сжатыми до целевого диаметра. При этом сравнение двух результатов со схожей длиной каркаса и возникающих значений S показало значительное различие в RF при достижении 6 мм (1374,198 Н и 284,240 Н). Представленный подход формирует базу для дальнейшей оптимизации каркасов с использованием генетических алгоритмов или Байесовских оптимизаторов и повышает возможность создания отечественных медицинских изделий нового поколения.
- 30 June 2026
- Published by PNRPU Publishing House in Российский журнал биомеханики
- Vol. 30 (2) , 50-59
Автоматизированный подход к параметрической генерации модели и мкэ-оценке процесса ее сжатия: пример каркаса транскатетерного протеза клапана сердца
В последние годы транскатетерные протезы клапанов сердца становятся все более востребованными из-за меньших рисков, относительной простоты имплантации и более быстрого восстановления по сравнению с открытыми операциями. Постоянный рост числа таких вмешательств в России требует разработки новых инструментов проектирования каркасов протезов. Цель исследования – разработать алгоритмический метод генерации параметризированных моделей каркасов транскатетерных протезов с последующей численной оценкой процесса их сжатия. Созданный подход включает в себя три блока, работающие в автоматическом режиме, что является основой для построения оптимизационного процесса: «Генератор» параметрических моделей, «Численный анализ» сжатия и автоматическая «Оценка» результатов. Для ее решения разработан алгоритм, реализованный на Python с использованием пакета CadQuery для создания геометрии и интеграции с программой численного анализа методом конечных элементов Abaqus/CAE. В отличие от существующих работ в данной тематике, важнейшим критерием новизны описанного материала является возможность разработки новых видов опорных каркасов транскатетерных протезов клапанов сердца на основе ограниченного только формой заложенной элементарной ячейки. В исследовании рассмотрено 1225 уникальных дизайнов, оцененных по критериям напряжения по Мизесу (S, МПа), силы реакции опоры (RF, Н) и величины эластической отдачи. Из полученных результатов 36 дизайнов показали возможность быть сжатыми до целевого диаметра. При этом сравнение двух результатов со схожей длиной каркаса и возникающих значений S показало значительное различие в RF при достижении 6 мм (1374,198 Н и 284,240 Н). Представленный подход формирует базу для дальнейшей оптимизации каркасов с использованием генетических алгоритмов или Байесовских оптимизаторов и повышает возможность создания отечественных медицинских изделий нового поколения.
- 31 March 2026
- Published by V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs in Russian Journal of Transplantology and Artificial Organs
- Vol. 28 (1)
Features of IgG subclass deposition in the biological component of epoxy-treated xenogenic bioprosthetic heart valves
Objective: to evaluate changes in the immunogenicity of epoxy-treated xenogeneic bioprosthetic heart valves (BHVs) during in vivo function by detecting human IgG antibodies in the biomaterial of explanted samples. Materials and methods. Fourteen BHVs explanted during repeat valve replacement were examined. Of these, three valves were removed at 1, 20, and 42 days after implantation, while 11 valves had functioned for periods ranging from 3 to 25 years. Histological sections were prepared from the valve leaflets and analyzed by immunohistochemistry using antibodies against human immunoglobulin G (IgG), as well as Russell–Movat pentachrome staining. Selected leaflet fragments were additionally examined by scanning electron microscopy. Results. BHVs removed due to early dysfunction after 1, 20, and 42 days of implantation showed no signs of biomaterial degeneration; however, small thrombi were detected on their leaflet surfaces. In contrast, valves that had functioned for 3 to 25 years exhibited clear features of structural degeneration of the biological tissue, including leaflet tears and extensive calcification. These BHVs were also characterized by moderate macrophage infiltration and a slight increase in pannus on the valve surface. Immunohistochemical staining of histological sections for human IgG revealed intense antibody deposition within the biomaterial of all examined BHVs, irrespective of implantation duration. Positive IgG staining was localized along the fibers of the xenogeneic tissue and was absent in recipient tissues, including thrombi and pannus. Conclusion. The biological component of BHVs retains its immunogenic properties even after long-term (up to 25 years) function in the recipient’s body.
- 31 March 2026
- Published by V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs in Russian Journal of Transplantology and Artificial Organs
- Vol. 28 (1)
Features of IgG subclass deposition in the biological component of epoxy-treated xenogenic bioprosthetic heart valves
Objective: to evaluate changes in the immunogenicity of epoxy-treated xenogeneic bioprosthetic heart valves (BHVs) during in vivo function by detecting human IgG antibodies in the biomaterial of explanted samples. Materials and methods. Fourteen BHVs explanted during repeat valve replacement were examined. Of these, three valves were removed at 1, 20, and 42 days after implantation, while 11 valves had functioned for periods ranging from 3 to 25 years. Histological sections were prepared from the valve leaflets and analyzed by immunohistochemistry using antibodies against human immunoglobulin G (IgG), as well as Russell–Movat pentachrome staining. Selected leaflet fragments were additionally examined by scanning electron microscopy. Results. BHVs removed due to early dysfunction after 1, 20, and 42 days of implantation showed no signs of biomaterial degeneration; however, small thrombi were detected on their leaflet surfaces. In contrast, valves that had functioned for 3 to 25 years exhibited clear features of structural degeneration of the biological tissue, including leaflet tears and extensive calcification. These BHVs were also characterized by moderate macrophage infiltration and a slight increase in pannus on the valve surface. Immunohistochemical staining of histological sections for human IgG revealed intense antibody deposition within the biomaterial of all examined BHVs, irrespective of implantation duration. Positive IgG staining was localized along the fibers of the xenogeneic tissue and was absent in recipient tissues, including thrombi and pannus. Conclusion. The biological component of BHVs retains its immunogenic properties even after long-term (up to 25 years) function in the recipient’s body.
- 31 March 2026
- Published by V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs in Russian Journal of Transplantology and Artificial Organs
- Vol. 28 (1)
nfluence of leaflet calcification patterns on the biomechanics of bioprosthetic mitral valves
Objective: to identify characteristic patterns of calcium distribution in explanted bioprosthetic heart valves and evaluate their influence on the biomechanics of the device. Materials and methods. Thirty-three bioprosthetic mitral valve leaflets explanted due to structural valve degeneration were analyzed. Multislice computed tomography (MSCT) images were used to identify pathological calcification within each leaflet. Calcified regions were segmented from top-view projections using a radiographic density threshold of 130 HU. The resulting dataset was clustered according to the number of pixels representing calcified areas, yielding three distinct classes: no calcification, mild calcification, and severe calcification. For each class, a three-dimensional computational model of the bioprosthesis was constructed. Biomechanical behavior was evaluated numerically in a series of computer simulation experiments using the finite element method. Each model included the supporting frame and three valve leaflets, with physiologically relevant boundary conditions simulating pressures in the left atrium and left ventricle. The analysis assessed maximum principal stress, strain, and their spatial distribution across the prosthesis. Results . Calcification of one or two valve leaflets resulted in a slight reduction in the average stress and strain values of the intact leaflet – from 0.319 to 0.303 MPa and from 0.134 to 0.130 mm/mm, respectively. Increased calcium content also lowered the peak stress and strain values, from 2.884 to 2.117 MPa and from 0.384 to 0.333 mm/mm. A clear relationship was observed between calcification pattern and local stress concentrations, which exceeded the leaflet’s mean stress values by 40–50%. Co-localization of mild or severe calcification clusters on one or two leaflets produced qualitative alterations in the closure mechanism, including «overlap» of mineralized leaflets over adjacent intact ones. Conclusion. The findings demonstrate a relationship between the stress–strain behavior of bioprosthetic valve leaflets and the spatial pattern of calcification. While an increase in calcium volume up to 28% does not substantially affect mean stress or strain values, it significantly reduces their peak values.
- 31 March 2026
- Published by V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs in Russian Journal of Transplantology and Artificial Organs
- Vol. 28 (1)
nfluence of leaflet calcification patterns on the biomechanics of bioprosthetic mitral valves
Objective: to identify characteristic patterns of calcium distribution in explanted bioprosthetic heart valves and evaluate their influence on the biomechanics of the device. Materials and methods. Thirty-three bioprosthetic mitral valve leaflets explanted due to structural valve degeneration were analyzed. Multislice computed tomography (MSCT) images were used to identify pathological calcification within each leaflet. Calcified regions were segmented from top-view projections using a radiographic density threshold of 130 HU. The resulting dataset was clustered according to the number of pixels representing calcified areas, yielding three distinct classes: no calcification, mild calcification, and severe calcification. For each class, a three-dimensional computational model of the bioprosthesis was constructed. Biomechanical behavior was evaluated numerically in a series of computer simulation experiments using the finite element method. Each model included the supporting frame and three valve leaflets, with physiologically relevant boundary conditions simulating pressures in the left atrium and left ventricle. The analysis assessed maximum principal stress, strain, and their spatial distribution across the prosthesis. Results . Calcification of one or two valve leaflets resulted in a slight reduction in the average stress and strain values of the intact leaflet – from 0.319 to 0.303 MPa and from 0.134 to 0.130 mm/mm, respectively. Increased calcium content also lowered the peak stress and strain values, from 2.884 to 2.117 MPa and from 0.384 to 0.333 mm/mm. A clear relationship was observed between calcification pattern and local stress concentrations, which exceeded the leaflet’s mean stress values by 40–50%. Co-localization of mild or severe calcification clusters on one or two leaflets produced qualitative alterations in the closure mechanism, including «overlap» of mineralized leaflets over adjacent intact ones. Conclusion. The findings demonstrate a relationship between the stress–strain behavior of bioprosthetic valve leaflets and the spatial pattern of calcification. While an increase in calcium volume up to 28% does not substantially affect mean stress or strain values, it significantly reduces their peak values.
- 30 December 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (6)
DEVELOPMENT OF CONCEPTS FOR PRIMARY HEART VALVE REPLACEMENT
Highlights Average cycle stress for the developed concepts was 413.6–528.0 MPa. Hydrodynamic tests were successful – effective orifice area was 3.41 ± 0.08 and 3.52 ± 0.07 cm 2 . Two frame concepts were unsuitable, and the third requires geometric optimization. Aim. To develop and analyze concepts of support frames for transcatheter aortic valves based on numerical modeling methods in order to evaluate their mechanical characteristics, strength properties and hydrodynamic efficiency. Methods. The study used three-dimensional models of the support frames created using SolidWorks software (Dassault Systemes, France). The mechanical characteristics were assessed in the Abaqus/CAE environment (Dassault Systèmes, France) using the finite element method. The study included an analysis of the stress-strain state, fatigue strength, and radial forces arising during crimping and implantation of the prosthesis. The hydrodynamic characteristics were assessed using the Pulse Duplicator II stand (Vivitro Labs, Canada), which simulates the operating conditions of the prosthesis in the left ventricle of the heart. Results. Numerical modeling analysis showed that two of the three concepts studied demonstrated exceedance of the material strength limit, which makes them unsuitable for further use. One of the concepts demonstrated lower stress levels, but some areas of the design require further refinement. Radial stability tests revealed a predictable pattern of material deformation, which confirms the stability of the design under physiological conditions. Hydrodynamic tests showed compliance of the valve operation with established standards, the absence of critical turbulence zones and acceptable regurgitation levels. Conclusion. The obtained results indicate the need for further optimization of the geometry of the supporting frame of the developed device to reduce local stresses, as well as improvement of the surface finishing technology to improve the roughness index. The manufactured prototypes of the prosthesis have satisfactory hydrodynamic characteristics.
- 30 December 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (6)
DEVELOPMENT OF CONCEPTS FOR PRIMARY HEART VALVE REPLACEMENT
Highlights Average cycle stress for the developed concepts was 413.6–528.0 MPa. Hydrodynamic tests were successful – effective orifice area was 3.41 ± 0.08 and 3.52 ± 0.07 cm 2 . Two frame concepts were unsuitable, and the third requires geometric optimization. Aim. To develop and analyze concepts of support frames for transcatheter aortic valves based on numerical modeling methods in order to evaluate their mechanical characteristics, strength properties and hydrodynamic efficiency. Methods. The study used three-dimensional models of the support frames created using SolidWorks software (Dassault Systemes, France). The mechanical characteristics were assessed in the Abaqus/CAE environment (Dassault Systèmes, France) using the finite element method. The study included an analysis of the stress-strain state, fatigue strength, and radial forces arising during crimping and implantation of the prosthesis. The hydrodynamic characteristics were assessed using the Pulse Duplicator II stand (Vivitro Labs, Canada), which simulates the operating conditions of the prosthesis in the left ventricle of the heart. Results. Numerical modeling analysis showed that two of the three concepts studied demonstrated exceedance of the material strength limit, which makes them unsuitable for further use. One of the concepts demonstrated lower stress levels, but some areas of the design require further refinement. Radial stability tests revealed a predictable pattern of material deformation, which confirms the stability of the design under physiological conditions. Hydrodynamic tests showed compliance of the valve operation with established standards, the absence of critical turbulence zones and acceptable regurgitation levels. Conclusion. The obtained results indicate the need for further optimization of the geometry of the supporting frame of the developed device to reduce local stresses, as well as improvement of the surface finishing technology to improve the roughness index. The manufactured prototypes of the prosthesis have satisfactory hydrodynamic characteristics.
- 30 December 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (6S)
SURFACE MODIFICATION OF BIODEGRADABLE ANTI-ADHESIVE MEMBRANES WITH POLYVINYL ALCOHOL TO IMPROVE BIOCOMPATIBILITY
Highlights Surface modification of biodegradable anti-adhesion membranes with polyvinyl alcohol improves the physical and mechanical properties and hemocompatibility of the products, but at the same time reduces the rate of biodegradation, which leads to calcification of the membranes during subcutaneous implantation in laboratory animals and requires the elimination of the negative impact. Aim . To evaluate the effect of surface modification with polyvinyl alcohol on the biocompatibility of anti-adhesion biopolymer membranes manufactured by electrospinning. Methods . Membranes were formed from a composition of poly (D, L-lactide-co-glycolide) (50:50) and poly (D, L-lactide-co-glycolide) (85:15), using 1,1,1,3,3,3-hexafluoroisopropanol as a solvent. Dexamethasone was added to impart anti-inflammatory activity. Membranes were formed by electrospinning, after which they were surface modified with a 0.5% aqueous solution of polyvinyl alcohol. Physicomechanical properties, hemocompatibility, biocompatibility, and in vivo degradation were assessed. Results . PVA modification in the dry state was accompanied by an increase in the tensile strength and a two-fold increase in Young's modulus with a comparable elongation at break. Two-minute hydration returned the modulus to its original values. The hemocompatible properties of all sample groups met the safety criterion for hemolysis (≤ 2%). The number of adherent cells in PM/DM/PVA decreased severalfold compared to PM and PM/DM, and the strain index decreased to 1.4 versus 2.33–2.42. After 14 days, PM and PM/DM demonstrated active fiber erosion, while PP/DM/PVA retained a continuous PVA layer and less pronounced surface degradation. By 3 months, PM had completely degraded, PM/DM remained as small fragments surrounded by macrophages, and a calcification contour was visualized for PM/DM/PVA. Conclusion . Modification of the polymer membrane surface with polyvinyl alcohol eliminated residual electrostatic stress and improved the physical, mechanical, and hemocompatibility properties. However, subcutaneous implantation in laboratory animals resulted in calcification of the samples. Therefore, further research is needed to evaluate optimization of the PVA layer to reduce the susceptibility to calcification.
- 30 December 2025
- Published by NII KPSSZ in Complex Issues of Cardiovascular Diseases
- Vol. 14 (6S)
SURFACE MODIFICATION OF BIODEGRADABLE ANTI-ADHESIVE MEMBRANES WITH POLYVINYL ALCOHOL TO IMPROVE BIOCOMPATIBILITY
Highlights Surface modification of biodegradable anti-adhesion membranes with polyvinyl alcohol improves the physical and mechanical properties and hemocompatibility of the products, but at the same time reduces the rate of biodegradation, which leads to calcification of the membranes during subcutaneous implantation in laboratory animals and requires the elimination of the negative impact. Aim . To evaluate the effect of surface modification with polyvinyl alcohol on the biocompatibility of anti-adhesion biopolymer membranes manufactured by electrospinning. Methods . Membranes were formed from a composition of poly (D, L-lactide-co-glycolide) (50:50) and poly (D, L-lactide-co-glycolide) (85:15), using 1,1,1,3,3,3-hexafluoroisopropanol as a solvent. Dexamethasone was added to impart anti-inflammatory activity. Membranes were formed by electrospinning, after which they were surface modified with a 0.5% aqueous solution of polyvinyl alcohol. Physicomechanical properties, hemocompatibility, biocompatibility, and in vivo degradation were assessed. Results . PVA modification in the dry state was accompanied by an increase in the tensile strength and a two-fold increase in Young's modulus with a comparable elongation at break. Two-minute hydration returned the modulus to its original values. The hemocompatible properties of all sample groups met the safety criterion for hemolysis (≤ 2%). The number of adherent cells in PM/DM/PVA decreased severalfold compared to PM and PM/DM, and the strain index decreased to 1.4 versus 2.33–2.42. After 14 days, PM and PM/DM demonstrated active fiber erosion, while PP/DM/PVA retained a continuous PVA layer and less pronounced surface degradation. By 3 months, PM had completely degraded, PM/DM remained as small fragments surrounded by macrophages, and a calcification contour was visualized for PM/DM/PVA. Conclusion . Modification of the polymer membrane surface with polyvinyl alcohol eliminated residual electrostatic stress and improved the physical, mechanical, and hemocompatibility properties. However, subcutaneous implantation in laboratory animals resulted in calcification of the samples. Therefore, further research is needed to evaluate optimization of the PVA layer to reduce the susceptibility to calcification.
- Open Access
- 15 October 2025
- Published by Siberian State Medical University in Bulletin of Siberian Medicine
- Vol. 24 (3) , 52-58
Hydrodynamic performance of a composite heart valve prosthesis
The aim of the study was to conduct a hydrodynamic assessment of the efficiency of heart valve prostheses made of xenopericardium protected by polyvinyl alcohol.Materials and methods. Experimental prostheses based on the UniLine bioprosthesis model were manufactured for the study. The xenopericardium used for the valve cusps was modified with polyvinyl alcohol to improve its resistance to biological and mechanical effects. Hydrodynamic tests were performed on a Pulse Duplicator system, which simulates the function of the “left heart”. The key parameters of the prosthesis operation were estimated including average transprosthetic gradient, effective orifice area, locking volume, and regurgitant volume. Unmodified prostheses of similar size were used as a control.Results. Hydrodynamic tests showed that the experimental prostheses demonstrate an increase in the average transprosthetic gradient to 6.59 mm Hg. (compared to 5.29 mm Hg in the control group) and a decrease in the effective orifice area to 1.52 cm² (1.69 cm² in the control group). The regurgitant volume also increased to 23.3 ml per cycle, which is higher than the control value of 12.2 ml per cycle. Despite this, all indicators remain within the permissible values established by the state standard (GOST).Conclusion. The use of polyvinyl alcohol to protect the xenopericardium demonstrates potential advantages such as increased resistance of the material to biological effects, but is accompanied by some decrease in the hydrodynamics of the prosthesis. Nevertheless, the efficiency indicators remain within the standards, which opens up opportunities for further improvement of the technology. It is necessary to continue research in order to optimize the material and design to improve both the biocompatibility and functional characteristics of the prosthesis.
- 15 October 2025
- Published by Siberian State Medical University in Bulletin of Siberian Medicine
- Vol. 24 (3) , 52-58
Open AccessHydrodynamic performance of a composite heart valve prosthesis
The aim of the study was to conduct a hydrodynamic assessment of the efficiency of heart valve prostheses made of xenopericardium protected by polyvinyl alcohol.Materials and methods. Experimental prostheses based on the UniLine bioprosthesis model were manufactured for the study. The xenopericardium used for the valve cusps was modified with polyvinyl alcohol to improve its resistance to biological and mechanical effects. Hydrodynamic tests were performed on a Pulse Duplicator system, which simulates the function of the “left heart”. The key parameters of the prosthesis operation were estimated including average transprosthetic gradient, effective orifice area, locking volume, and regurgitant volume. Unmodified prostheses of similar size were used as a control.Results. Hydrodynamic tests showed that the experimental prostheses demonstrate an increase in the average transprosthetic gradient to 6.59 mm Hg. (compared to 5.29 mm Hg in the control group) and a decrease in the effective orifice area to 1.52 cm² (1.69 cm² in the control group). The regurgitant volume also increased to 23.3 ml per cycle, which is higher than the control value of 12.2 ml per cycle. Despite this, all indicators remain within the permissible values established by the state standard (GOST).Conclusion. The use of polyvinyl alcohol to protect the xenopericardium demonstrates potential advantages such as increased resistance of the material to biological effects, but is accompanied by some decrease in the hydrodynamics of the prosthesis. Nevertheless, the efficiency indicators remain within the standards, which opens up opportunities for further improvement of the technology. It is necessary to continue research in order to optimize the material and design to improve both the biocompatibility and functional characteristics of the prosthesis.
- Open Access
- 5 October 2025
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 40 (3) , 225-234
Concept of automatic development of polymer heart valve prosthesis
Aim: To validate an automated design algorithm for the leaflet apparatus of a polymeric heart valve prosthesis, focusing on achieving high hydrodynamic performance through design, prototyping, and in vitro testing.Material and Methods. The study employs a proprietary automated design algorithm based on computational modeling and numerical analysis of the hydrodynamic characteristics of heart valve prosthesis leaflets in computational modeling. The algorithm generated a large number of geometrical variants (over 16,000), which were subsequently evaluated for their functionality, including the effective orifice area, coaptation area, and stress distribution within the leaflet material. Based on the design algorithm's output, the optimal leaflet geometry was selected and prototyped using casting techniques to produce three samples. These prototypes were evaluated in vitro under simulated physiological flow conditions using a hydrodynamic testing system.Results. The geometries produced by the design algorithm exhibited a wide range of quantitative metrics for the targets: the mean effective orifice area was 38.85% (minimum 7.54%; maximum 85.78%); the coaptation area was 1.08% (0–1.88%); and the maximum stress was 0.47 MPa (0.25–1.43 MPa). The optimal leaflet geometry selected for prototyping demonstrated an effective orifice area of 85.75%, a coaptation area of 0.45%, and a maximum stress of 1.023 MPa. Prototyping and subsequent in vitro testing confirmed the high functional performance of the developed sample, although significant deviations in quantitative indicators from the results of numerical modeling were observed due to the specifics of prototyping. These discrepancies indicate the need for further refinement of the algorithm and improvements in the prototyping methodology.Conclusion. The study confirms the effectiveness of the proposed automated algorithm for the development and optimization of polymeric heart valve prostheses. The primary advantage of this methodology lies in its ability to rapidly generate and evaluate a large number of geometrical variants, thereby enhancing the accuracy and functionality of the final product. The results demonstrate the significant potential of automated design in biomedical engineering and pave the way for the development of more advanced medical devices. Future efforts should focus on improving the accuracy of numerical models and prototyping techniques to ensure even higher quality and durability of polymeric heart valve prostheses.
- 5 October 2025
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 40 (3) , 225-234
Open AccessConcept of automatic development of polymer heart valve prosthesis
Aim: To validate an automated design algorithm for the leaflet apparatus of a polymeric heart valve prosthesis, focusing on achieving high hydrodynamic performance through design, prototyping, and in vitro testing.Material and Methods. The study employs a proprietary automated design algorithm based on computational modeling and numerical analysis of the hydrodynamic characteristics of heart valve prosthesis leaflets in computational modeling. The algorithm generated a large number of geometrical variants (over 16,000), which were subsequently evaluated for their functionality, including the effective orifice area, coaptation area, and stress distribution within the leaflet material. Based on the design algorithm's output, the optimal leaflet geometry was selected and prototyped using casting techniques to produce three samples. These prototypes were evaluated in vitro under simulated physiological flow conditions using a hydrodynamic testing system.Results. The geometries produced by the design algorithm exhibited a wide range of quantitative metrics for the targets: the mean effective orifice area was 38.85% (minimum 7.54%; maximum 85.78%); the coaptation area was 1.08% (0–1.88%); and the maximum stress was 0.47 MPa (0.25–1.43 MPa). The optimal leaflet geometry selected for prototyping demonstrated an effective orifice area of 85.75%, a coaptation area of 0.45%, and a maximum stress of 1.023 MPa. Prototyping and subsequent in vitro testing confirmed the high functional performance of the developed sample, although significant deviations in quantitative indicators from the results of numerical modeling were observed due to the specifics of prototyping. These discrepancies indicate the need for further refinement of the algorithm and improvements in the prototyping methodology.Conclusion. The study confirms the effectiveness of the proposed automated algorithm for the development and optimization of polymeric heart valve prostheses. The primary advantage of this methodology lies in its ability to rapidly generate and evaluate a large number of geometrical variants, thereby enhancing the accuracy and functionality of the final product. The results demonstrate the significant potential of automated design in biomedical engineering and pave the way for the development of more advanced medical devices. Future efforts should focus on improving the accuracy of numerical models and prototyping techniques to ensure even higher quality and durability of polymeric heart valve prostheses.