    HYDRODYNAMIC CHARACTERISTICS OF UNILINE BIOPROSTHESES IN VARIOUS MODES

    by Kirill Yu. Klyshnikov, Aleksandr A. Aronov, Pavel S. Onishchenko, Tatyana V. Glushkova, Alexander E. Kostyunin, Tatyana N. Akentyeva, Marina P. Fokeeva, Evgeny A. Ovcharenko, Kristina S. Mitrofanova, Кирилл Юрьевич Клышников, et al.

    Highlights The study provides the first extended in vitro assessment of UniLine bioprostheses across six standardized pressure modes: from hypotension to very severe hypertension, establishing reference hydrodynamic values for domestic heart valve technologies. The bioprostheses demonstrated high stability of essential performance metrics (effective orifice area 1.45–1.53 cm²; mean gradient 4.23–4.38 mmHg) under increasing hemodynamic loads, confirming the adequacy of their structural design and reliability across a broad spectrum of simulated clinical conditions. Regurgitation values under extreme loading revealed intrinsic variability of biological tissues, highlighting the need to account for biomechanical heterogeneity in future engineering optimization and comparative evaluation of domestic bioprosthetic Aim. To evaluate the hydrodynamic performance of the domestic atrioventricular bioprosthesis UniLine (size 26 mm) under multiple loading modes defined by GOST 31618.1-2012. Methods. Twelve prostheses were tested in vitro using the Pulse Duplicator II across six pressure modes: from hypotensive (60/40 mmHg) to very severe hypertension (210/120 mmHg). Heart rate was set at 70 bpm with 35% systolic duration. Three metrics were assessed: mean transvalvular gradient, effective orifice area, and regurgitant volume. Data are presented as median [25 th ; 75 th percentile]. Results . Effective orifice area remained stable across modes (1.45–1.53 cm²; range 1.39–1.81 cm²). Mean gradient remained low, from 4.23 mmHg in hypotension to 4.32–4.38 mmHg in severe/very severe hypertension (overall range 1.55–6.03 mmHg). Regurgitant volume increased with pressure load, from 2.66 to 4.09 mL/cycle (maximum 8.04 mL/cycle in individual tests). All parameters met GOST and ISO requirements. Conclusion . UniLine bioprostheses demonstrate stable hydrodynamic behavior across a broad range of loading conditions, characterized by low gradients, consistent effective orifice area, and acceptable regurgitation. These results provide reference values supporting further optimization and extended preclinical evaluation.

  • Open Access

    MODELING THE DESIGN OF THE EXPANDABLE HEART VALVE PROSTHESIS

    by Kirill Yu. Klyshnikov, Pavel S. Onishchenko, Kristina S. Mitrofanova, Tatyana V. Glushkova, Alexander E. Kostyunin, Tatyana N. Akentyeva, Marina P. Fokeeva, Evgeny A. Ovcharenko, Кирилл Юрьевич Клышников, Павел Сергеевич Онищенко, et al.

    MODELING THE DESIGN OF THE EXPANDABLE HEART VALVE PROSTHESIS | Klyshnikov | Complex Issues of Cardiovascular Diseases МОДЕЛИРОВАНИЕ КОНСТРУКЦИИ РАЗДВИЖНОГО ПРОТЕЗА КЛАПАНА СЕРДЦА | Клышников | Комплексные проблемы сердечно-сосудистых заболеваний

  • Features of IgG subclass deposition in the biological component of epoxy-treated xenogenic bioprosthetic heart valves

    by A. E. Kostyunin, T. V. Glushkova, A. A. Klyueva, T. N. Akentyeva, L. A. Bogdanov, R. A. Mukhamadiyarov, K. Yu. Klyshnikov, P. S. Onishchenko, E. А. Ovcharenko

    Objective: to evaluate changes in the immunogenicity of epoxy-treated xenogeneic bioprosthetic heart valves (BHVs) during in vivo function by detecting human IgG antibodies in the biomaterial of explanted samples. Materials and methods. Fourteen BHVs explanted during repeat valve replacement were examined. Of these, three valves were removed at 1, 20, and 42 days after implantation, while 11 valves had functioned for periods ranging from 3 to 25 years. Histological sections were prepared from the valve leaflets and analyzed by immunohistochemistry using antibodies against human immunoglobulin G (IgG), as well as Russell–Movat pentachrome staining. Selected leaflet fragments were additionally examined by scanning electron microscopy. Results. BHVs removed due to early dysfunction after 1, 20, and 42 days of implantation showed no signs of biomaterial degeneration; however, small thrombi were detected on their leaflet surfaces. In contrast, valves that had functioned for 3 to 25 years exhibited clear features of structural degeneration of the biological tissue, including leaflet tears and extensive calcification. These BHVs were also characterized by moderate macrophage infiltration and a slight increase in pannus on the valve surface. Immunohistochemical staining of histological sections for human IgG revealed intense antibody deposition within the biomaterial of all examined BHVs, irrespective of implantation duration. Positive IgG staining was localized along the fibers of the xenogeneic tissue and was absent in recipient tissues, including thrombi and pannus. Conclusion. The biological component of BHVs retains its immunogenic properties even after long-term (up to 25 years) function in the recipient’s body.

  • Diversity of Bacterial Agents in Leaflets of Epoxy-Treated Bioprosthetic Heart Valves Removed due to Structural Valvular Degeneration

    by A. E. Kostyunin, A. V. Sinitskaya, T. V. Glushkova, A. O. Poddubnyak, A. A. Klueva, T. N. Akentieva, A. E. Tupikin, M. R. Kabilov, M. Yu. Sinitsky

    Aim. To study the taxonomic composition of bacteria present in the leaflets of bioprosthetic heart valves (BHVs) explanted due to structural valve degenera

  • Nitrogen plasma modification of ePTFE for cardiovascular implantology applications

    by Alena G. Korzhova, Olesya A. Laput, Anastasia A. Bryuzgina, Ulyana V. Khomutova, Yelena G. Shapovalova, Lubov V. Domracheva, Irina V. Vasenina, Yuriy H. Akhmadeev, Evgeny A. Ovcharenko, Maria A. Rezvova, et al.

  • Open Access

    Image-based clustering analysis of calcification patterns in bioprosthetic heart valves

    by E. A. Ovcharenko, K. Yu. Klyshnikov, P. S. Onishchenko, A. E. Kostyunin, A. A. Khromov, A. N. Stasev, T. N. Akentyeva, M. P. Fokeeva, O. L. Barbarash, T. V. Glushkova

    Objective: to identify key patterns of calcification in explanted bioprosthetic heart valves (BHVs) using cluster analysis of computed tomography-derived graphical data. Materials and methods. The study included 11 UniLine BHVs that were routinely explanted during reoperations for structural valve dysfunction. Computed tomography was used to obtain DICOM images of each sample, followed by generation of maximum intensity projections and segmentation of the valves into individual leaflets (n = 33). The images were pre-processed using binary thresholding to differentiate calcified regions from non-calcified biological tissue. Cluster analysis was performed using various algorithms: Gaussian mixture models, Ordering Points To Identify the Clustering Structure (OPTICS), k-means clustering, agglomerative (hierarchical) clustering, and spectral clustering. A basic quantitative method assessing the proportion of pixels corresponding to calcified areas was used for comparison. The performance of clustering algorithms was evaluated using the silhouette score. The presence of calcium deposits in the valves and the accuracy of binary thresholding were further verified histologically by alizarin red S staining of valve cryosections. Results. Data preprocessing based on image binarization yielded a maximum silhouette score of 0.55. Among the clustering algorithms, the highest silhouette scores were achieved with the agglomerative (0.55) and k-means (0.54) methods; however, both demonstrated substantial data imbalance, with up to 85% of samples grouped within a single cluster, limiting their practical applicability. The most balanced clustering was achieved using spectral clustering (silhouette score 0.45) and the basic quantitative approach (0.44). Both methods identified three distinct patterns of bioprosthetic valve leaflet calcification: (1) non-calcified leaflets, (2) partial calcification, and (3) total calcification. Conclusion. Three key calcification patterns were identified in explanted BHVs – absence of calcium, partial calcification, and total calcification. Spectral clustering and the basic quantitative method demonstrated the most balanced results, while other algorithms showed pronounced cluster imbalance. Heat map analysis revealed that in partial calcification, mineral deposition typically begins in the commissural and dome regions of the leaflets, near the free edge, and in total calcification, extends across the entire dome and leaflet base.

  • DEVELOPMENT OF CONCEPTS FOR PRIMARY HEART VALVE REPLACEMENT

    by Kirill Yu. Klyshnikov, Pavel S. Onishchenko, Tatyana V. Glushkova, Alexander E. Kostyunin, Tatyana N. Akentyeva, Kristina S. Mitrofanova, Aleksandr A. Aronov, Marina P. Fokeeva, Olga L. Barbarash, Evgeny A. Ovcharenko

    Highlights Average cycle stress for the developed concepts was 413.6–528.0 MPa. Hydrodynamic tests were successful – effective orifice area was 3.41 ± 0.08 and 3.52 ± 0.07 cm 2 . Two frame concepts were unsuitable, and the third requires geometric optimization. Aim. To develop and analyze concepts of support frames for transcatheter aortic valves based on numerical modeling methods in order to evaluate their mechanical characteristics, strength properties and hydrodynamic efficiency. Methods. The study used three-dimensional models of the support frames created using SolidWorks software (Dassault Systemes, France). The mechanical characteristics were assessed in the Abaqus/CAE environment (Dassault Systèmes, France) using the finite element method. The study included an analysis of the stress-strain state, fatigue strength, and radial forces arising during crimping and implantation of the prosthesis. The hydrodynamic characteristics were assessed using the Pulse Duplicator II stand (Vivitro Labs, Canada), which simulates the operating conditions of the prosthesis in the left ventricle of the heart. Results. Numerical modeling analysis showed that two of the three concepts studied demonstrated exceedance of the material strength limit, which makes them unsuitable for further use. One of the concepts demonstrated lower stress levels, but some areas of the design require further refinement. Radial stability tests revealed a predictable pattern of material deformation, which confirms the stability of the design under physiological conditions. Hydrodynamic tests showed compliance of the valve operation with established standards, the absence of critical turbulence zones and acceptable regurgitation levels. Conclusion. The obtained results indicate the need for further optimization of the geometry of the supporting frame of the developed device to reduce local stresses, as well as improvement of the surface finishing technology to improve the roughness index. The manufactured prototypes of the prosthesis have satisfactory hydrodynamic characteristics.

  • SURFACE MODIFICATION OF BIODEGRADABLE ANTI-ADHESIVE MEMBRANES WITH POLYVINYL ALCOHOL TO IMPROVE BIOCOMPATIBILITY

    by Yulia A. Kudryavtseva, Anastasia Yu. Kanonykina, Pavel S. Onishchenko, Vladislav A. Koshelev, Tatyana N. Akentyeva

    Highlights Surface modification of biodegradable anti-adhesion membranes with polyvinyl alcohol improves the physical and mechanical properties and hemocompatibility of the products, but at the same time reduces the rate of biodegradation, which leads to calcification of the membranes during subcutaneous implantation in laboratory animals and requires the elimination of the negative impact.   Aim . To evaluate the effect of surface modification with polyvinyl alcohol on the biocompatibility of anti-adhesion biopolymer membranes manufactured by electrospinning. Methods . Membranes were formed from a composition of poly (D, L-lactide-co-glycolide) (50:50) and poly (D, L-lactide-co-glycolide) (85:15), using 1,1,1,3,3,3-hexafluoroisopropanol as a solvent. Dexamethasone was added to impart anti-inflammatory activity. Membranes were formed by electrospinning, after which they were surface modified with a 0.5% aqueous solution of polyvinyl alcohol. Physicomechanical properties, hemocompatibility, biocompatibility, and in vivo degradation were assessed. Results . PVA modification in the dry state was accompanied by an increase in the tensile strength and a two-fold increase in Young's modulus with a comparable elongation at break. Two-minute hydration returned the modulus to its original values. The hemocompatible properties of all sample groups met the safety criterion for hemolysis (≤ 2%). The number of adherent cells in PM/DM/PVA decreased severalfold compared to PM and PM/DM, and the strain index decreased to 1.4 versus 2.33–2.42. After 14 days, PM and PM/DM demonstrated active fiber erosion, while PP/DM/PVA retained a continuous PVA layer and less pronounced surface degradation. By 3 months, PM had completely degraded, PM/DM remained as small fragments surrounded by macrophages, and a calcification contour was visualized for PM/DM/PVA. Conclusion . Modification of the polymer membrane surface with polyvinyl alcohol eliminated residual electrostatic stress and improved the physical, mechanical, and hemocompatibility properties. However, subcutaneous implantation in laboratory animals resulted in calcification of the samples. Therefore, further research is needed to evaluate optimization of the PVA layer to reduce the susceptibility to calcification.

  • Method of non-destructive analysis of heart valve prostheses based on CT data

    by P. S. Onishchenko, K. Yu. Klyshnikov, T. V. Glushkova, A. A. Khromov, A. E. Kostyunin, T. N. Akentyeva, A. N. Stasev, A. V. Evtushenko, E. A. Ovcharenko

    Background. Heart valve biopstheses are widely used in the surgical treatment of acquired heart valve defects. However, their main drawback remains progressive structural dysfunction, which requires replacement of up to 50 % of implants after 10–15 years. Modern diagnostic methods are needed to analyze the causes of dysfunction. One of the most promising methods is computed tomography (CT) with subsequent three-dimensional reconstruction of DICOM images, which allows for detailed visualization of the entire prosthesis as a whole, rather than just its individual fragments. Objective. To develop a method for non-destructive analysis of the calcification of biological heart valve prostheses based on computed tomography data. Materials and Methods. Two domestic “UniLine” bioprostheses with similar service lives (4 years 6 months and 5 years 9 months), but different degrees of calcification, were studied. Both prostheses were scanned using a clinical LightSpeed VCT CT scanner. The obtained DICOM images were processed using specially developed algorithms to construct three-dimensional models and calculate the volume of calcifications. Results. The first prosthesis, explanted earlier (after 4 years and 6 months), was significantly more calcified. Its total volume of calcification together with the metal frame was 129.53 mm³. In the second sample (service life 5 years 9 months), a lower calcification volume was recorded — 68.95 mm³ (the volume of the frame itself) — confirming a minimal degree of calcium deposition. Conclusion. The developed CT analysis method has proven effective for non-destructive research into the structural changes of bioprostheses. Nevertheless, there are certain limitations due to the equipment’s resolution and the difficulty of differentiating metal components from calcium deposits. This approach requires further improvement but already represents a valuable tool for the objective assessment of the condition of implanted devices.

  • Open Access

    Hydrodynamic performance of a composite heart valve prosthesis

    by K. Yu. Klyshnikov, A. E. Kostyunin, P. S. Onishchenko, T. V. Glushkova, T. N. Akentyeva, N. N. Borisova, A. G. Kutikhin, E. A. Ovcharenko

    The aim of the study was to conduct a hydrodynamic assessment of the efficiency of heart valve prostheses made of xenopericardium protected by polyvinyl alcohol.Materials and methods. Experimental prostheses based on the UniLine bioprosthesis model were manufactured for the study. The xenopericardium used for the valve cusps was modified with polyvinyl alcohol to improve its resistance to biological and mechanical effects. Hydrodynamic tests were performed on a Pulse Duplicator system, which simulates the function of the “left heart”. The key parameters of the prosthesis operation were estimated including average transprosthetic gradient, effective orifice area, locking volume, and regurgitant volume. Unmodified prostheses of similar size were used as a control.Results. Hydrodynamic tests showed that the experimental prostheses demonstrate an increase in the average transprosthetic gradient to 6.59 mm Hg. (compared to 5.29 mm Hg in the control group) and a decrease in the effective orifice area to 1.52 cm² (1.69 cm² in the control group). The regurgitant volume also increased to 23.3 ml per cycle, which is higher than the control value of 12.2 ml per cycle. Despite this, all indicators remain within the permissible values established by the state standard (GOST).Conclusion. The use of polyvinyl alcohol to protect the xenopericardium demonstrates potential advantages such as increased resistance of the material to biological effects, but is accompanied by some decrease in the hydrodynamics of the prosthesis. Nevertheless, the efficiency indicators remain within the standards, which opens up opportunities for further improvement of the technology. It is necessary to continue research in order to optimize the material and design to improve both the biocompatibility and functional characteristics of the prosthesis.