Measuring polyethylene wear in total knee arthroplasty by RSA: Differences between weight‐bearing and non‐weight‐bearing positioning
Open Access
- 7 January 2014
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 32 (4) , 613-617
Abstract
Measuring the minimum-joint-space-width (mJSW) in total knee arthroplasty (TKA) in Roentgen stereophotogrammetric analysis (RSA) provides valuable information on polyethylene wear, a leading cause for TKA failure. Most existing studies use non-weight-bearing (NWB) patient positioning. The latter may compromise mJSW measurements due to knee laxity with subsequent non-contact between the TKA components. We investigated the difference in mJSW between weight-bearing (WB) and NWB images and the association with mediolateral (ML) knee stability. At one-year follow-up, 23 TKAs were included from an ongoing RSA study, and ML stability was evaluated. For each examination, the mJSW and femoral-tibial contact locations were measured. A linear regression model was used to analyze the association between the mJSW difference (NWB–WB) with the ML stability and contact locations. The mean mJSW difference was 0.28 mm medially and 0.20 mm laterally. Four TKAs had medium (5–9°) and 19 TKAs had high (P = 0.01). In conclusion, mJSW measurements in existing (NWB) RSA studies are influenced by knee laxity, but may still provide information on wear progression based on TKA with high ML stability. A direct comparison of mJSW measurements from WB and NWB data is not possible. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:613–617, 2014.Keywords
This publication has 27 references indexed in Scilit:
- Knee replacementThe Lancet, 2012
- Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030Clinical Orthopaedics and Related Research, 2009
- Standing versus Supine Radiographs in RSA Evaluation of Femoral Head PenetrationClinical Orthopaedics and Related Research, 2006
- Which radiographic techniques should we use for research and clinical practice?Best Practice & Research Clinical Rheumatology, 2006
- Aseptic loosening, not only a question of wear: A review of different theoriesActa Orthopaedica, 2006
- Imaging of knee arthroplastyEuropean Journal of Radiology, 2005
- The influence of design, materials and kinematics on the in vitro wear of total knee replacementsJournal of Biomechanics, 2005
- In vitro assessment of proximal polyethylene contact surface areas and stresses in mobile bearing kneesMedical Engineering & Physics, 2003
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Past incidence and future demand for knee arthroplasty in Sweden: A report from the Swedish Knee Arthroplasty Register regarding the effect of past and future population changes on the number of arthroplasties performedActa Orthopaedica, 2000