Emiel A. van Ijsseldijk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Emiel A. van Ijsseldijk has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bart L. Kaptein
Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
4 shared publications B.C. Stoel
3 shared publicationsE.R. Valstar
3 shared publications- Rob Gerardus Henricus Hubertus Nelissen
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
3 shared publications B. Lebel
1 shared publicationBerend C. Stoel
Department of Radiology Division of Image Processing, Leiden University Medical Center Leiden The Netherlands
1 shared publication
Latest Publications
- Open Access
- 7 January 2014
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 32 (4) , 613-617
Measuring polyethylene wear in total knee arthroplasty by RSA: Differences between weight‐bearing and non‐weight‐bearing positioning
Measuring the minimum-joint-space-width (mJSW) in total knee arthroplasty (TKA) in Roentgen stereophotogrammetric analysis (RSA) provides valuable information on polyethylene wear, a leading cause for TKA failure. Most existing studies use non-weight-bearing (NWB) patient positioning. The latter may compromise mJSW measurements due to knee laxity with subsequent non-contact between the TKA components. We investigated the difference in mJSW between weight-bearing (WB) and NWB images and the association with mediolateral (ML) knee stability. At one-year follow-up, 23 TKAs were included from an ongoing RSA study, and ML stability was evaluated. For each examination, the mJSW and femoral-tibial contact locations were measured. A linear regression model was used to analyze the association between the mJSW difference (NWB–WB) with the ML stability and contact locations. The mean mJSW difference was 0.28 mm medially and 0.20 mm laterally. Four TKAs had medium (5–9°) and 19 TKAs had high (P = 0.01). In conclusion, mJSW measurements in existing (NWB) RSA studies are influenced by knee laxity, but may still provide information on wear progression based on TKA with high ML stability. A direct comparison of mJSW measurements from WB and NWB data is not possible. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:613–617, 2014.
- 7 January 2014
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 32 (4) , 613-617
Open AccessMeasuring polyethylene wear in total knee arthroplasty by RSA: Differences between weight‐bearing and non‐weight‐bearing positioning
Measuring the minimum-joint-space-width (mJSW) in total knee arthroplasty (TKA) in Roentgen stereophotogrammetric analysis (RSA) provides valuable information on polyethylene wear, a leading cause for TKA failure. Most existing studies use non-weight-bearing (NWB) patient positioning. The latter may compromise mJSW measurements due to knee laxity with subsequent non-contact between the TKA components. We investigated the difference in mJSW between weight-bearing (WB) and NWB images and the association with mediolateral (ML) knee stability. At one-year follow-up, 23 TKAs were included from an ongoing RSA study, and ML stability was evaluated. For each examination, the mJSW and femoral-tibial contact locations were measured. A linear regression model was used to analyze the association between the mJSW difference (NWB–WB) with the ML stability and contact locations. The mean mJSW difference was 0.28 mm medially and 0.20 mm laterally. Four TKAs had medium (5–9°) and 19 TKAs had high (P = 0.01). In conclusion, mJSW measurements in existing (NWB) RSA studies are influenced by knee laxity, but may still provide information on wear progression based on TKA with high ML stability. A direct comparison of mJSW measurements from WB and NWB data is not possible. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:613–617, 2014.
- 1 April 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (7) , 1387-1391
Validation of the in vivo volumetric wear measurement for total knee prostheses in model-based RSA
- 1 April 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (7) , 1387-1391
Validation of the in vivo volumetric wear measurement for total knee prostheses in model-based RSA
- 1 August 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45 (12) , 2171-2175
A model-based approach to measure the minimum joint space width of total knee replacements in standard radiographs
- 1 August 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45 (12) , 2171-2175
A model-based approach to measure the minimum joint space width of total knee replacements in standard radiographs
- 1 October 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44 (15) , 2724-2727
The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA
- 1 October 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44 (15) , 2724-2727
The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA