Prestressed concrete (PC) sleepers have been treated as replacement track materials that are replaced each time deformation occurs. For this reason, so far, no criteria have been established for quantitative soundness assessment nor for replacement of these sleepers. In this research, to establish a new maintenance management system of PC sleepers, we collected aged PC sleepers to conduct a survey of aging deterioration, with various tests such as bending tests specified by Japanese Industrial Standards (JIS). Using the results, we evaluated the load-bearing capacity of aged PC sleepers through numerical analyses using a three-dimensional FEM model. Finally, we proposed a guideline for the service life of PC sleepers.Keywords
This publication has 4 references indexed in Scilit:
- Investigation of Load Environment and Bending Load Capacities of Aged Prestressed Concrete SleepersApplied Sciences, 2023
- Fatigue Life Evaluation of PC Sleepers Based on Wheel Load Measurement ResultsQuarterly Report of RTRI, 2022
- Validation of a dynamic wheel load factor and the influence of various track irregularities on the dynamic response of prestressed concrete sleepersProceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, 2019
- CDPM2: A damage-plasticity approach to modelling the failure of concreteInternational Journal of Solids and Structures, 2013