Fast parametric beamformer for synthetic aperture imaging
- 8 August 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (8) , 1755-1767
Abstract
This paper describes the design and implementation of a real-time delay-and-sum synthetic aperture beamformer. The beamforming delays and apodization coefficients are described parametrically. The image is viewed as a set of independent lines that are defined in 3D by their origin, direction, and inter-sample distance. The delay calculation is recursive and inspired by the coordinate rotation digital computer (CORDIC) algorithm. Only 3 parameters per channel and line are needed for their generation. The calculation of apodization coefficients is based on a piece- wise linear approximation. The implementation of the beamformer is optimized with respect to the architecture of a novel synthetic aperture real-time ultrasound scanner (SARUS), in which 4 channels are processed by the same set of field-programmable gate arrays (FPGA). In synthetic transmit aperture imaging, low-resolution images are formed after every emission. Summing all low-resolution images produces a perfectly focused high-resolution image. The design of the beamformer is modular, and a single beamformation unit can produce 4600 low-resolution images per second, each consisting of 32 lines and 1024 complex samples per line. In its present incarnation, 3 such modules fit in a single device. The summation of low-resolution images is performed internally in the FPGA to reduce the required bandwidth. The delays are calculated with a precision of 1/16th of a sample, and the apodization coefficients with 7-bit precision. The accumulation of low-resolution images is performed with 24-bit precision. The level of the side- and grating lobes, introduced by the use of integer numbers in the calculations and truncation of intermediate results, is below -86 dB from the peak.Keywords
This publication has 36 references indexed in Scilit:
- In-vivo evaluation of convex array synthetic aperture imagingUltrasound in Medicine & Biology, 2007
- Directional synthetic aperture flow imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2004
- In-vivo synthetic aperture flow imaging in medical ultrasoundIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003
- Multielement synthetic transmit aperture imaging using temporal encodingIEEE Transactions on Medical Imaging, 2003
- Motion estimation using common spatial frequencies in synthetic aperture imaging2002
- Sparse array imaging with spatially-encoded transmits2002
- Effects and limitations of motion compensation in synthetic aperture techniques2002
- Low power delay calculation for digital beamforming in handheld ultrasound systems2000
- Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- Synthetic focus imaging using partial datasets1994