SNSvetoslav Ivanov Nikolov

Svetoslav Ivanov Nikolov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Svetoslav Ivanov Nikolov has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Synthetic aperture focusing for a single-element transducer undergoing helical motion

    by Henrik Andresen, S I Nikolov, J A Jensen

    This paper describes the application of 3-D synthetic aperture focusing (SAF) to a single-element trans-rectal ultrasound transducer. The transducer samples a 3-D volume by simultaneous rotation and translation, giving a helical motion. Two different 3-D SAF methods are investigated, a direct and a two-step approach. Both methods perform almost identically for simulated scatterers and give a significant improvement in azimuth resolution and a constant resolution in elevation. Side lobes below -60 dB are achievable for both methods. Validation of the method is achieved by scanning a simple wire phantom and a complex phantom containing wires in azimuth and elevation. The simple wire phantom shows the same results as that found through simulation. The complex phantom shows simultaneous focusing in azimuth and elevation for the wire scatterers. Consideration of the processing requirements for both 3-D SAF methods shows that the two-step approach can give equivalent performance using an order of magnitude fewer calculations. This reduction requires a temporary storage of 9.1 GB of data for the investigated setup.


  • Precise time-of-flight calculation for 3-D synthetic aperture focusing

    by Henrik Andresen, Svetoslav Ivanov Nikolov, Jorgen Arendt Jensen

    Conventional linear arrays can be used for 3-D ultrasound imaging by moving the array in the elevation direction and stacking the planes in a volume. The point-spread function is larger in the elevation plane, because the aperture is smaller and has a fixed elevation focus. Resolution improvements in elevation can be achieved by applying synthetic aperture focusing to the beamformed-in-plane RF data. The proposed method uses a virtual source placed at the elevation focus for postbeamforming. This has previously been done in 2 steps, in-plane focusing followed by synthetic aperture post-focusing in elevation, due to lack of a simple expression for the exact time of flight. This paper presents a new single step method for calculating the time of flight for a 3-D case using a linear array. The new method is more flexible and is able to beamform a fewer number of points much more efficiently. The method is evaluated using both simulated data and phantom measurements using the RASMUS experimental scanner. Computational cost of the method is higher than the 2-step method for a full volume beamforming, but it allows for a reduction of an order-of-magnitude if 3 planes are used for real-time visualization. In addition, the need for a temporary storage of beamformed data is removed.


  • Fast parametric beamformer for synthetic aperture imaging

    by Svetoslav Ivanov Nikolov, Jorgen Arendt Jensen, Borislav Gueorguiev Tomov

    This paper describes the design and implementation of a real-time delay-and-sum synthetic aperture beamformer. The beamforming delays and apodization coefficients are described parametrically. The image is viewed as a set of independent lines that are defined in 3D by their origin, direction, and inter-sample distance. The delay calculation is recursive and inspired by the coordinate rotation digital computer (CORDIC) algorithm. Only 3 parameters per channel and line are needed for their generation. The calculation of apodization coefficients is based on a piece- wise linear approximation. The implementation of the beamformer is optimized with respect to the architecture of a novel synthetic aperture real-time ultrasound scanner (SARUS), in which 4 channels are processed by the same set of field-programmable gate arrays (FPGA). In synthetic transmit aperture imaging, low-resolution images are formed after every emission. Summing all low-resolution images produces a perfectly focused high-resolution image. The design of the beamformer is modular, and a single beamformation unit can produce 4600 low-resolution images per second, each consisting of 32 lines and 1024 complex samples per line. In its present incarnation, 3 such modules fit in a single device. The summation of low-resolution images is performed internally in the FPGA to reduce the required bandwidth. The delays are calculated with a precision of 1/16th of a sample, and the apodization coefficients with 7-bit precision. The accumulation of low-resolution images is performed with 24-bit precision. The level of the side- and grating lobes, introduced by the use of integer numbers in the calculations and truncation of intermediate results, is below -86 dB from the peak.


  • Open Access

    OC095: Synthetic aperture imaging in medical ultrasound

    by S. I. Nikolov, K. L. Gammelmark, M. H. Pedersen, B. G. Tomov, J. A. Jensen