Svetoslav Ivanov Nikolov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Svetoslav Ivanov Nikolov has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jorgen Arendt Jensen
Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark
4 shared publications B. G. Tomov
Technical University of Denmark, Denmark
1 shared publication- Borislav Gueorguiev Tomov
Department of Health Technology, Center for Fast Ultrasound Imaging, Technical University of Denmark, Kongens Lyngby, Denmark
1 shared publication Henrik Andresen
Center for Fast Ultrasound Imaging, DTU Elektro, Technical University of Denmark, Lyngby, Denmark
1 shared publication- Henrik Andresen
Center for Fast Ultrasound Imaging, DTU Elektro, Technical University of Denmark, Lyngby, Denmark
1 shared publication - K. L. Gammelmark
Technical University of Denmark, Denmark
1 shared publication
Latest Publications
- 27 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 58 (5) , 935-943
Synthetic aperture focusing for a single-element transducer undergoing helical motion
This paper describes the application of 3-D synthetic aperture focusing (SAF) to a single-element trans-rectal ultrasound transducer. The transducer samples a 3-D volume by simultaneous rotation and translation, giving a helical motion. Two different 3-D SAF methods are investigated, a direct and a two-step approach. Both methods perform almost identically for simulated scatterers and give a significant improvement in azimuth resolution and a constant resolution in elevation. Side lobes below -60 dB are achievable for both methods. Validation of the method is achieved by scanning a simple wire phantom and a complex phantom containing wires in azimuth and elevation. The simple wire phantom shows the same results as that found through simulation. The complex phantom shows simultaneous focusing in azimuth and elevation for the wire scatterers. Consideration of the processing requirements for both 3-D SAF methods shows that the two-step approach can give equivalent performance using an order of magnitude fewer calculations. This reduction requires a temporary storage of 9.1 GB of data for the investigated setup.
- 27 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 58 (5) , 935-943
Synthetic aperture focusing for a single-element transducer undergoing helical motion
This paper describes the application of 3-D synthetic aperture focusing (SAF) to a single-element trans-rectal ultrasound transducer. The transducer samples a 3-D volume by simultaneous rotation and translation, giving a helical motion. Two different 3-D SAF methods are investigated, a direct and a two-step approach. Both methods perform almost identically for simulated scatterers and give a significant improvement in azimuth resolution and a constant resolution in elevation. Side lobes below -60 dB are achievable for both methods. Validation of the method is achieved by scanning a simple wire phantom and a complex phantom containing wires in azimuth and elevation. The simple wire phantom shows the same results as that found through simulation. The complex phantom shows simultaneous focusing in azimuth and elevation for the wire scatterers. Consideration of the processing requirements for both 3-D SAF methods shows that the two-step approach can give equivalent performance using an order of magnitude fewer calculations. This reduction requires a temporary storage of 9.1 GB of data for the investigated setup.
- 6 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (9) , 1880-1887
Precise time-of-flight calculation for 3-D synthetic aperture focusing
Conventional linear arrays can be used for 3-D ultrasound imaging by moving the array in the elevation direction and stacking the planes in a volume. The point-spread function is larger in the elevation plane, because the aperture is smaller and has a fixed elevation focus. Resolution improvements in elevation can be achieved by applying synthetic aperture focusing to the beamformed-in-plane RF data. The proposed method uses a virtual source placed at the elevation focus for postbeamforming. This has previously been done in 2 steps, in-plane focusing followed by synthetic aperture post-focusing in elevation, due to lack of a simple expression for the exact time of flight. This paper presents a new single step method for calculating the time of flight for a 3-D case using a linear array. The new method is more flexible and is able to beamform a fewer number of points much more efficiently. The method is evaluated using both simulated data and phantom measurements using the RASMUS experimental scanner. Computational cost of the method is higher than the 2-step method for a full volume beamforming, but it allows for a reduction of an order-of-magnitude if 3 planes are used for real-time visualization. In addition, the need for a temporary storage of beamformed data is removed.
- 6 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (9) , 1880-1887
Precise time-of-flight calculation for 3-D synthetic aperture focusing
Conventional linear arrays can be used for 3-D ultrasound imaging by moving the array in the elevation direction and stacking the planes in a volume. The point-spread function is larger in the elevation plane, because the aperture is smaller and has a fixed elevation focus. Resolution improvements in elevation can be achieved by applying synthetic aperture focusing to the beamformed-in-plane RF data. The proposed method uses a virtual source placed at the elevation focus for postbeamforming. This has previously been done in 2 steps, in-plane focusing followed by synthetic aperture post-focusing in elevation, due to lack of a simple expression for the exact time of flight. This paper presents a new single step method for calculating the time of flight for a 3-D case using a linear array. The new method is more flexible and is able to beamform a fewer number of points much more efficiently. The method is evaluated using both simulated data and phantom measurements using the RASMUS experimental scanner. Computational cost of the method is higher than the 2-step method for a full volume beamforming, but it allows for a reduction of an order-of-magnitude if 3 planes are used for real-time visualization. In addition, the need for a temporary storage of beamformed data is removed.
- 8 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (8) , 1755-1767
Fast parametric beamformer for synthetic aperture imaging
This paper describes the design and implementation of a real-time delay-and-sum synthetic aperture beamformer. The beamforming delays and apodization coefficients are described parametrically. The image is viewed as a set of independent lines that are defined in 3D by their origin, direction, and inter-sample distance. The delay calculation is recursive and inspired by the coordinate rotation digital computer (CORDIC) algorithm. Only 3 parameters per channel and line are needed for their generation. The calculation of apodization coefficients is based on a piece- wise linear approximation. The implementation of the beamformer is optimized with respect to the architecture of a novel synthetic aperture real-time ultrasound scanner (SARUS), in which 4 channels are processed by the same set of field-programmable gate arrays (FPGA). In synthetic transmit aperture imaging, low-resolution images are formed after every emission. Summing all low-resolution images produces a perfectly focused high-resolution image. The design of the beamformer is modular, and a single beamformation unit can produce 4600 low-resolution images per second, each consisting of 32 lines and 1024 complex samples per line. In its present incarnation, 3 such modules fit in a single device. The summation of low-resolution images is performed internally in the FPGA to reduce the required bandwidth. The delays are calculated with a precision of 1/16th of a sample, and the apodization coefficients with 7-bit precision. The accumulation of low-resolution images is performed with 24-bit precision. The level of the side- and grating lobes, introduced by the use of integer numbers in the calculations and truncation of intermediate results, is below -86 dB from the peak.
- 8 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (8) , 1755-1767
Fast parametric beamformer for synthetic aperture imaging
This paper describes the design and implementation of a real-time delay-and-sum synthetic aperture beamformer. The beamforming delays and apodization coefficients are described parametrically. The image is viewed as a set of independent lines that are defined in 3D by their origin, direction, and inter-sample distance. The delay calculation is recursive and inspired by the coordinate rotation digital computer (CORDIC) algorithm. Only 3 parameters per channel and line are needed for their generation. The calculation of apodization coefficients is based on a piece- wise linear approximation. The implementation of the beamformer is optimized with respect to the architecture of a novel synthetic aperture real-time ultrasound scanner (SARUS), in which 4 channels are processed by the same set of field-programmable gate arrays (FPGA). In synthetic transmit aperture imaging, low-resolution images are formed after every emission. Summing all low-resolution images produces a perfectly focused high-resolution image. The design of the beamformer is modular, and a single beamformation unit can produce 4600 low-resolution images per second, each consisting of 32 lines and 1024 complex samples per line. In its present incarnation, 3 such modules fit in a single device. The summation of low-resolution images is performed internally in the FPGA to reduce the required bandwidth. The delays are calculated with a precision of 1/16th of a sample, and the apodization coefficients with 7-bit precision. The accumulation of low-resolution images is performed with 24-bit precision. The level of the side- and grating lobes, introduced by the use of integer numbers in the calculations and truncation of intermediate results, is below -86 dB from the peak.
- Open Access
- 26 August 2004
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 24 (3) , 242
OC095: Synthetic aperture imaging in medical ultrasound
- 26 August 2004
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 24 (3) , 242
Open AccessOC095: Synthetic aperture imaging in medical ultrasound