Borislav Gueorguiev Tomov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Borislav Gueorguiev Tomov has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Jorgen Arendt Jensen
Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark
33 shared publications - Matthias Bo Stuart
Department of Health Technology, Center for Fast Ultrasound Imaging, Technical University of Denmark, Lyngby, Denmark
13 shared publications - Erik Vilain Thomsen
Technical University of Denmark
7 shared publications Michael Johannes Pihl
Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
6 shared publications- Michael Bachmann Nielsen
Department of Radiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark
5 shared publications - Morten Fischer Rasmussen
Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark
5 shared publications
Latest Publications
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 251-271
512 + 512 Anodically Bonded Row-Column Addressed CMUT Array Fabrication and Characterization
In the pursuit of 3-D super-resolution ultrasound imaging, transducer arrays with apertures on the size of cm and sub 60 μm pitch are required, necessitating many elements and high-frequency operation. This work presents the fabrication process development and characterization of a λ/2 pitch 512+512 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array. The fabrication process was optimized by addressing key challenges in anodic bonding, specifically vertical short circuits, which severely limit the yield. Process optimization was performed to understand these shorts and a low-voltage 150 V anodic bonding solution was implemented to mitigate them. The complete process flow is detailed. Electrical characterization confirmed reliable CMUT operation with a 99% yield. To evaluate the acoustic performance, a 128+128 RCA CMUT array fabricated using the same process flow was integrated into a modular probe and characterized using a Vantage 256 scanner. Imaging performance of the RCA 128+128 CMUT probe was tested using a 3-D hydrogel scatter phantom with a grid of 205×205×80 μm3 targets and a wire phantom, demonstrating an axial and lateral resolution at −6 dB of 1.28λ (0.18 mm) and 1.55λ (0.22 mm).
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 251-271
512 + 512 Anodically Bonded Row-Column Addressed CMUT Array Fabrication and Characterization
In the pursuit of 3-D super-resolution ultrasound imaging, transducer arrays with apertures on the size of cm and sub 60 μm pitch are required, necessitating many elements and high-frequency operation. This work presents the fabrication process development and characterization of a λ/2 pitch 512+512 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array. The fabrication process was optimized by addressing key challenges in anodic bonding, specifically vertical short circuits, which severely limit the yield. Process optimization was performed to understand these shorts and a low-voltage 150 V anodic bonding solution was implemented to mitigate them. The complete process flow is detailed. Electrical characterization confirmed reliable CMUT operation with a 99% yield. To evaluate the acoustic performance, a 128+128 RCA CMUT array fabricated using the same process flow was integrated into a modular probe and characterized using a Vantage 256 scanner. Imaging performance of the RCA 128+128 CMUT probe was tested using a 3-D hydrogel scatter phantom with a grid of 205×205×80 μm3 targets and a wire phantom, demonstrating an axial and lateral resolution at −6 dB of 1.28λ (0.18 mm) and 1.55λ (0.22 mm).
- Open Access
- 20 January 2025
- Published by Elsevier in Ultrasonics
- Vol. 149, 107574
Precision of in vivo pressure gradient estimations using synthetic aperture ultrasound
- 20 January 2025
- Published by Elsevier in Ultrasonics
- Vol. 149, 107574
Open AccessPrecision of in vivo pressure gradient estimations using synthetic aperture ultrasound
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (2) , 238-250
Beamformer for a Lensed Row–Column Array in 3-D Ultrasound Imaging
Row-column (RC) arrays typically suffer from a limited field of view (FOV), with the imaging area confined to a rectangular region equal to the footprint of the probe. This limitation can be solved by using a diverging lens in front of the probe. Previous studies have introduced a Thin Lens model for beamforming lensed RC arrays, but this model inaccurately assumes the lens to be infinitely thin, leading to degraded resolution and contrast due to errors in the time of flight (TOF) calculations. This paper presents a beamformer based on ray tracing for accurate TOF calculation. A Verasonics Vantage 256 scanner was equipped with a Vermon RC probe with 128 + 128 elements, λ pitch, and a 6 MHz center frequency. A synthetic aperture ultrasound sequence with 96 virtual sources and 32 active elements for each emission with row elements was employed, and all column elements were used for acquiring data. This method was tested with a polystyrene (PS) lens with a spherical shape and polymethyl methacrylate (PMMA) in a Bicylindrical shape. Based on pressure field measurements, these two lenses provide a 20° and 33° FOV, respectively. The Thin Lens model had a lateral resolution of around 17.4λ for the Bicylindrical lens, whereas the new method achieves a resolution of around 3.8λ, representing a 4.6-fold improvement. The contrast is enhanced from 23.1 to 29.8 dB for the Bicylindrical lens while preserving the FOV.
- 6 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (2) , 238-250
Beamformer for a Lensed Row–Column Array in 3-D Ultrasound Imaging
Row-column (RC) arrays typically suffer from a limited field of view (FOV), with the imaging area confined to a rectangular region equal to the footprint of the probe. This limitation can be solved by using a diverging lens in front of the probe. Previous studies have introduced a Thin Lens model for beamforming lensed RC arrays, but this model inaccurately assumes the lens to be infinitely thin, leading to degraded resolution and contrast due to errors in the time of flight (TOF) calculations. This paper presents a beamformer based on ray tracing for accurate TOF calculation. A Verasonics Vantage 256 scanner was equipped with a Vermon RC probe with 128 + 128 elements, λ pitch, and a 6 MHz center frequency. A synthetic aperture ultrasound sequence with 96 virtual sources and 32 active elements for each emission with row elements was employed, and all column elements were used for acquiring data. This method was tested with a polystyrene (PS) lens with a spherical shape and polymethyl methacrylate (PMMA) in a Bicylindrical shape. Based on pressure field measurements, these two lenses provide a 20° and 33° FOV, respectively. The Thin Lens model had a lateral resolution of around 17.4λ for the Bicylindrical lens, whereas the new method achieves a resolution of around 3.8λ, representing a 4.6-fold improvement. The contrast is enhanced from 23.1 to 29.8 dB for the Bicylindrical lens while preserving the FOV.
- Open Access
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 925-944
Super-Resolution Ultrasound Imaging Using the Erythrocytes—Part I: Density Images
A new approach for vascular super resolution imaging using the erythrocytes as targets (SURE imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index for ultrasound scanning for an increased penetration depth. A synthetic aperture ultrasound sequence was employed with 12 virtual sources using a 10 MHz GE L8-18i-D linear array hockey stick probe. The axial resolution was 1.20λ,(185.0μm) and the lateral resolution was 1.50λ,(231.3μm). Field IIpro simulations were conducted on 12.5 μm radius vessel pairs with varying separations. A vessel pair with a separation of 70 μm could be resolved, indicating a SURE image resolution below half a wavelength. A Verasonics research scanner was used for the in vivo experiments to scan the kidneys of Sprague-Dawley rats for up to 46 s to visualize their microvasculature by processing from 0.1 up to 45 s of data for SURE imaging, and for 46.8 s for super resolution (SR) imaging with a SonoVue contrast agent. Afterward, the renal vasculature was filled with the ex vivo micro-CT contrast agent Microfil, excised, and scanned in a micro-CT scanner at both a 22.6 μm voxel size for 11 hours, and for 20 hours in a 5 μm voxel size for validating the SURE images. Comparing the SURE and micro-CT images revealed that vessels with a diameter of 28 μm, five times smaller than the ultrasound wavelength, could be detected, and the dense grid of microvessels in the full kidney was shown for scan times between 1 to 10 s. The vessel structure in the cortex was also similar for the SURE and SR images. Fourier ring correlation indicated a resolution capability of 29 μm. SURE images are acquired in seconds rather than minutes without any patient preparation or contrast injection, making the method translatable to clinical use.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 925-944
Open AccessSuper-Resolution Ultrasound Imaging Using the Erythrocytes—Part I: Density Images
A new approach for vascular super resolution imaging using the erythrocytes as targets (SURE imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index for ultrasound scanning for an increased penetration depth. A synthetic aperture ultrasound sequence was employed with 12 virtual sources using a 10 MHz GE L8-18i-D linear array hockey stick probe. The axial resolution was 1.20λ,(185.0μm) and the lateral resolution was 1.50λ,(231.3μm). Field IIpro simulations were conducted on 12.5 μm radius vessel pairs with varying separations. A vessel pair with a separation of 70 μm could be resolved, indicating a SURE image resolution below half a wavelength. A Verasonics research scanner was used for the in vivo experiments to scan the kidneys of Sprague-Dawley rats for up to 46 s to visualize their microvasculature by processing from 0.1 up to 45 s of data for SURE imaging, and for 46.8 s for super resolution (SR) imaging with a SonoVue contrast agent. Afterward, the renal vasculature was filled with the ex vivo micro-CT contrast agent Microfil, excised, and scanned in a micro-CT scanner at both a 22.6 μm voxel size for 11 hours, and for 20 hours in a 5 μm voxel size for validating the SURE images. Comparing the SURE and micro-CT images revealed that vessels with a diameter of 28 μm, five times smaller than the ultrasound wavelength, could be detected, and the dense grid of microvessels in the full kidney was shown for scan times between 1 to 10 s. The vessel structure in the cortex was also similar for the SURE and SR images. Fourier ring correlation indicated a resolution capability of 29 μm. SURE images are acquired in seconds rather than minutes without any patient preparation or contrast injection, making the method translatable to clinical use.
- Open Access
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 945-959
Super-Resolution Ultrasound Imaging Using the Erythrocytes—Part II: Velocity Images
Super resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared to several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time, however, the tracking of uncorrelated and high-density scatterers is quite challenging. This paper hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture imaging, motion estimation, echo canceling, peak detection, and recursive nearest neighbor tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125 to 25 μm wall-to-wall tube distances, as well as a 3D-printed hydrogel micro-flow phantom with 100 to 60 μm wall-to-wall channel distances. The comparison of an in-vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-CT scans with voxel sizes of 26.5μm and 5μm demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 945-959
Open AccessSuper-Resolution Ultrasound Imaging Using the Erythrocytes—Part II: Velocity Images
Super resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared to several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time, however, the tracking of uncorrelated and high-density scatterers is quite challenging. This paper hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture imaging, motion estimation, echo canceling, peak detection, and recursive nearest neighbor tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125 to 25 μm wall-to-wall tube distances, as well as a 3D-printed hydrogel micro-flow phantom with 100 to 60 μm wall-to-wall channel distances. The comparison of an in-vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-CT scans with voxel sizes of 26.5μm and 5μm demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.
- 25 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (1) , 202-213
Diverging Polymer Acoustic Lens Design for High-Resolution Row–Column Array Ultrasound Transducers
Spherical diverging acoustic lenses mounted on flat 2D Row-Column Addressed (RCA) ultrasound transducers have shown the potential to extend the Field of View (FOV) from a rectilinear to a curvilinear volume region and thereby enable 3D imaging of large organs. Such lenses are usually designed for small aperture low-frequency transducers, which have limited resolution. Moreover, they are made of off-the-shelf pieces of materials, which leaves no room for optimization. We hypothesize that acoustic lenses can be designed to fit high-resolution transducers and they can be fabricated in a fast, cost-effective, and flexible manner using a combination of 3D printing and casting or CNC machining techniques. These lenses should increase the FOV of the array while preserving the image quality. In this work, such lenses are made in concave, convex, and compound spherical shapes, and from thermoplastics and thermosetting polymers. Polymethylpentene (TPX), Polystyrene (PS), Polypropylene (PP), Polymethyl methacrylate (PMMA), Polydimethylsiloxane (PDMS) and Room-temperature-vulcanizing silicone (RTV) diverging lenses have been fabricated and mounted on a 128+128 6 MHz RCA transducer. The performances of the lenses have been assessed and compared in terms of FOV, Signal to Noise Ratio (SNR), bandwidth, and potential artefacts. The largest FOV (24.0°) is obtained with a 42.64 mm radius PMMA-RTV compound lens, which maintains a decent fractional bandwidth (53%) and SNR at 6 MHz (-9.1 dB amplitude drop compared to the unlensed transducer). The simple PMMA TPX, PS, PP, PDMS and RTV lenses provide a FOV of 12.2°, 6.3°, 8.1°, 11.7°, 0.6° and 10.4°, a fractional bandwidth of 97%, 46%, 103%, 46%, 97%, 53% and 49%, and an amplitude drop of -5.2 dB, -4.4 dB, -2.8 dB, -15.4 dB, -6.0 dB and -1.8 dB respectively. This work demonstrates that thermoplastics are suitable materials for fabricating low-attenuation convex diverging lenses for large-aperture, high-frequency 2D transducers. This is highly desired to achieve high-resolution volumetric imaging of large organs.
- 25 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (1) , 202-213
Diverging Polymer Acoustic Lens Design for High-Resolution Row–Column Array Ultrasound Transducers
Spherical diverging acoustic lenses mounted on flat 2D Row-Column Addressed (RCA) ultrasound transducers have shown the potential to extend the Field of View (FOV) from a rectilinear to a curvilinear volume region and thereby enable 3D imaging of large organs. Such lenses are usually designed for small aperture low-frequency transducers, which have limited resolution. Moreover, they are made of off-the-shelf pieces of materials, which leaves no room for optimization. We hypothesize that acoustic lenses can be designed to fit high-resolution transducers and they can be fabricated in a fast, cost-effective, and flexible manner using a combination of 3D printing and casting or CNC machining techniques. These lenses should increase the FOV of the array while preserving the image quality. In this work, such lenses are made in concave, convex, and compound spherical shapes, and from thermoplastics and thermosetting polymers. Polymethylpentene (TPX), Polystyrene (PS), Polypropylene (PP), Polymethyl methacrylate (PMMA), Polydimethylsiloxane (PDMS) and Room-temperature-vulcanizing silicone (RTV) diverging lenses have been fabricated and mounted on a 128+128 6 MHz RCA transducer. The performances of the lenses have been assessed and compared in terms of FOV, Signal to Noise Ratio (SNR), bandwidth, and potential artefacts. The largest FOV (24.0°) is obtained with a 42.64 mm radius PMMA-RTV compound lens, which maintains a decent fractional bandwidth (53%) and SNR at 6 MHz (-9.1 dB amplitude drop compared to the unlensed transducer). The simple PMMA TPX, PS, PP, PDMS and RTV lenses provide a FOV of 12.2°, 6.3°, 8.1°, 11.7°, 0.6° and 10.4°, a fractional bandwidth of 97%, 46%, 103%, 46%, 97%, 53% and 49%, and an amplitude drop of -5.2 dB, -4.4 dB, -2.8 dB, -15.4 dB, -6.0 dB and -1.8 dB respectively. This work demonstrates that thermoplastics are suitable materials for fabricating low-attenuation convex diverging lenses for large-aperture, high-frequency 2D transducers. This is highly desired to achieve high-resolution volumetric imaging of large organs.
- 9 September 2023
- Published by Elsevier in Ultrasonics
- Vol. 136, 107148
Thermal analysis and SNR comparison of CMUT and PZT transducers using coded excitation
- 9 September 2023
- Published by Elsevier in Ultrasonics
- Vol. 136, 107148
Thermal analysis and SNR comparison of CMUT and PZT transducers using coded excitation
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (7) , 708-720
Universal Synthetic Aperture Sequence for Anatomic, Functional, and Super Resolution Imaging
Synthetic Aperture (SA) can be used for both anatomic and functional imaging, where tissue motion and blood velocity are revealed. Often, sequences optimized for anatomic B-mode imaging are different from functional sequences, as the best distribution and number of emissions are different. B-mode sequences demand many emissions for a high contrast, whereas flow sequences demand short sequences for high correlations yielding accurate velocity estimates. This paper hypothesizes that a single, universal sequence can be developed for linear array SA imaging. This sequence yields high quality linear and non-linear B-mode images as well as accurate motion and flow estimates for high and low blood velocities and super resolution images. Interleaved sequences with positive and negative pulse emissions for the same spherical virtual source were used to enable flow estimation for high velocities and make continuous long acquisitions for low velocity estimation. An optimized pulse inversion (PI) sequence with 2×12 virtual sources was implemented for four different linear array probes connected to either a Verasonics Vantage 256 scanner or the SARUS experimental scanner. The virtual sources were evenly distributed over the whole aperture and permuted in emission order for making flow estimation possible using 4, 8, or 12 virtual sources. The frame rate was 208 Hz for fully independent images for a pulse repetition frequency of 5 kHz, and recursive imaging yielded 5,000 images per second. Data were acquired from a phantom mimicking the carotid artery with pulsating flow and the kidney of a Sprague-Dawley rat. Examples include anatomic high contrast B-mode, non-linear B-mode, tissue motion, power Doppler, color flow mapping, vector velocity imaging and super resolution imaging derived from the same data set and demonstrates that all imaging modes can be shown retrospectively and quantitative data derived from it.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (7) , 708-720
Universal Synthetic Aperture Sequence for Anatomic, Functional, and Super Resolution Imaging
Synthetic Aperture (SA) can be used for both anatomic and functional imaging, where tissue motion and blood velocity are revealed. Often, sequences optimized for anatomic B-mode imaging are different from functional sequences, as the best distribution and number of emissions are different. B-mode sequences demand many emissions for a high contrast, whereas flow sequences demand short sequences for high correlations yielding accurate velocity estimates. This paper hypothesizes that a single, universal sequence can be developed for linear array SA imaging. This sequence yields high quality linear and non-linear B-mode images as well as accurate motion and flow estimates for high and low blood velocities and super resolution images. Interleaved sequences with positive and negative pulse emissions for the same spherical virtual source were used to enable flow estimation for high velocities and make continuous long acquisitions for low velocity estimation. An optimized pulse inversion (PI) sequence with 2×12 virtual sources was implemented for four different linear array probes connected to either a Verasonics Vantage 256 scanner or the SARUS experimental scanner. The virtual sources were evenly distributed over the whole aperture and permuted in emission order for making flow estimation possible using 4, 8, or 12 virtual sources. The frame rate was 208 Hz for fully independent images for a pulse repetition frequency of 5 kHz, and recursive imaging yielded 5,000 images per second. Data were acquired from a phantom mimicking the carotid artery with pulsating flow and the kidney of a Sprague-Dawley rat. Examples include anatomic high contrast B-mode, non-linear B-mode, tissue motion, power Doppler, color flow mapping, vector velocity imaging and super resolution imaging derived from the same data set and demonstrates that all imaging modes can be shown retrospectively and quantitative data derived from it.
- Open Access
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 220-236
A Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging
This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz center frequency in immersion and a pitch of$95~\mu $ m which corresponds to$\approx ~\lambda $ /4. The array has a$2.14\times2.14$ cm$^{2}$ footprint including an integrated apodization scheme to reduce ghost echoes when performing ultrasound imaging. The array was fabricated using a combination of fusion and anodic bonding, and a deposit, remove, etch, multistep (DREM) etch to reduce substrate coupling and improve electrode conductivity. The transducer array was wire-bonded to a rigid-flex printed circuit board (PCB), encapsulated in room temperature vulcanizing (RTV) silicone polymer, electromagnetic interference (EMI) shielded, and mounted in a 3D-milled PPSU probe handle. The probe was characterized using the SARUS experimental scanner and 3D volumetric imaging was demonstrated on scatter and wire phantoms. The imaging depth was derived from tissue mimicking phantom measurements (0.5 dB MHz$^{-1} \text{cm}^{-1}$ attenuation) by estimating the SNR at varying depths. For a synthetic aperture imaging sequence with 96+96 emissions the imaging depth was 3.6 cm. The center frequency measured from the impulse response spectra in transmit and pulse-echo was 6.0 ± 0.9 MHz and 5.3 ± 0.4 MHz, and the corresponding relative bandwidths were 62.8 ± 4.5 % and 86.2 ± 10.4 %. The fabrication process showed clear improvement in relative receive sensitivity and transmit pressure uniformity compared to earlier silicon-on-insulator (SOI) based designs. However, at the same time it presented yield problems resulting in only around 55 % elements with a good response.- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 220-236
Open AccessA Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging
This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz center frequency in immersion and a pitch of$95~\mu $ m which corresponds to$\approx ~\lambda $ /4. The array has a$2.14\times2.14$ cm$^{2}$ footprint including an integrated apodization scheme to reduce ghost echoes when performing ultrasound imaging. The array was fabricated using a combination of fusion and anodic bonding, and a deposit, remove, etch, multistep (DREM) etch to reduce substrate coupling and improve electrode conductivity. The transducer array was wire-bonded to a rigid-flex printed circuit board (PCB), encapsulated in room temperature vulcanizing (RTV) silicone polymer, electromagnetic interference (EMI) shielded, and mounted in a 3D-milled PPSU probe handle. The probe was characterized using the SARUS experimental scanner and 3D volumetric imaging was demonstrated on scatter and wire phantoms. The imaging depth was derived from tissue mimicking phantom measurements (0.5 dB MHz$^{-1} \text{cm}^{-1}$ attenuation) by estimating the SNR at varying depths. For a synthetic aperture imaging sequence with 96+96 emissions the imaging depth was 3.6 cm. The center frequency measured from the impulse response spectra in transmit and pulse-echo was 6.0 ± 0.9 MHz and 5.3 ± 0.4 MHz, and the corresponding relative bandwidths were 62.8 ± 4.5 % and 86.2 ± 10.4 %. The fabrication process showed clear improvement in relative receive sensitivity and transmit pressure uniformity compared to earlier silicon-on-insulator (SOI) based designs. However, at the same time it presented yield problems resulting in only around 55 % elements with a good response. - Top Cited PapersOpen Access
- 15 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (10) , 2722-2738
Anatomic and Functional Imaging Using Row–Column Arrays
Row–column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator’s workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below $20~ \mu \text{m}$ . RC arrays can, thus, yield full 3-D imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.
- 15 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (10) , 2722-2738
Top Cited PapersOpen AccessAnatomic and Functional Imaging Using Row–Column Arrays
Row–column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator’s workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below $20~ \mu \text{m}$ . RC arrays can, thus, yield full 3-D imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.