Clinical evaluation of a new set of image quality criteria for mammography
Authors:
- A. GrahnAGA. Grahn
- B. HemdalBHB. Hemdal
- I. AnderssonIAI. Andersson
- M. RuschinMRM. Ruschin
- A. Thilander-KlangATA. Thilander-Klang
- S. BörjessonSBS. Börjesson
- A. TingbergATA. Tingberg
- S. MattssonSMS. Mattsson
- M. HåkanssonMHM. Håkansson
- M. BåthMBM. Båth
- L. G. MånssonLML. G. Månsson
- J. MedinJMJ. Medin
- 17 May 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 114 (1-3) , 389-394
Abstract
The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.Keywords
This publication has 10 references indexed in Scilit:
- Can the average glandular dose in routine digital mammography screening be reduced? a pilot study using revised image quality criteriaRadiation Protection Dosimetry, 2005
- The use of reference image criteria in X-ray diagnostics: an application for the optimisation of lumbar spine radiographsEuropean Radiology, 2004
- The Gothenburg Breast Screening TrialCancer, 2003
- An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammographyPhysics in Medicine & Biology, 2003
- Long-term effects of mammography screening: updated overview of the Swedish randomised trialsThe Lancet, 2002
- The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteriaBritish Journal of Radiology, 2002
- The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria.British Journal of Radiology, 2000
- The Influence of Different Technique Factors on Image Quality for Chest Radiographys: Application of the Recent CEC Image Quality CriteriaRadiation Protection Dosimetry, 2000
- Breast dosimetryApplied Radiation and Isotopes, 1998
- Evaluation of the European image quality criteria for chest examinationsBritish Journal of Radiology, 1995