Procedural outcome of lead explant and countertraction-assisted femoral lead extraction in Thai patients with cardiac implantable electronic device infection
Open Access
- 1 October 2021
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 37 (5) , 1124-1130
Abstract
Background: Cardiac implantable electronic device (CIED) implantation rate has been increasing worldwide. Despite proper surgical technique and preincisional intravenous antibiotics, the incidence of infected CIED remains high and leads to serious complications. When encountered with CIED infection, complete CIED system removal is indicated. Several lead extraction approaches have shown a high success rate. However, the facilities are limited in Thailand. In our current practice, we perform lead extraction using the Dotter basket snare femoral approach as our primary method. There are no prior data on this countertraction-assisted transfemoral technique. Therefore, we aim to study the procedural outcome of countertraction-assisted transfemoral lead removal technique of CIED infection in Thai patients. Methods: Patients diagnosed with CIED infection and with a history of device infection were retrospectively included. Simple manual removal was performed. In case of failure, we proceeded with the modified countertraction-assisted transfemoral technique. Results: There were 35 patients in the study. The success rate was 94.3%. Most of the leads, 62.8%, were removed by simple manual traction. In the 37.1% who required further femoral approach lead extractions, procedural failure was observed in 5.7% and procedure-related adverse events in 5.6%. CIED infection-related death accounted for 5.7% and nosocomial infection-related death, 2.8%. Conclusion: The success rate of CIED infection lead explant and countertraction-assisted transfemoral lead extraction technique was high with small complications and can be performed without advanced facilities. However, the procedure required a main center with a cardiovascular thoracic surgery support team.Keywords
This publication has 17 references indexed in Scilit:
- Rates of and Factors Associated With Infection in 200 909 Medicare Implantable Cardioverter-Defibrillator ImplantsCirculation, 2014
- Impact of a femoral snare approach as a bailout procedure on success rates in lead extractionsInteractive CardioVascular and Thoracic Surgery, 2014
- The Needle's Eye Snare as a primary tool for pacing lead extractionEP Europace, 2012
- Cardiac device infections are associated with a significant mortality riskHeart Rhythm, 2012
- Mortality and Cost Associated With Cardiovascular Implantable Electronic Device InfectionsArchives of internal medicine (1960), 2011
- Trans-venous lead removal without the use of extraction sheaths, results of >250 removal proceduresEP Europace, 2011
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- Device‐Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and ConsequencesJournal of Cardiovascular Electrophysiology, 2010
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Risk Factors for Mortality in Patients With Cardiac Device-Related InfectionCirculation: Arrhythmia and Electrophysiology, 2009