The Needle's Eye Snare as a primary tool for pacing lead extraction
Authors:
Open Access
- 30 December 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (7) , 1007-1012
Abstract
The femoral approach for lead extraction is typically used as a bailout procedure. We describe the results of a femoral approach with a Needle's Eye Snare and Femoral Workstation as a primary tool for extracting pacing leads. Four hundred and seventy-six pacing leads implanted for >6 months were extracted in 229 consecutive patients (178 male, age 70.4 ± 12.7 years). First, traction was performed with a standard stylet, and if unsuccessful this was followed by the femoral approach with a Needle's Eye Snare. Traction sufficed for 136 leads and a femoral approach was required in 340 leads, their respective implant times were 3.7 ± 2.9 and 9.2 ± 5.8 years. The Needle's Eye Snare failed or was only partial successful (leaving a lead remnant of <4 cm) in, respectively, 1.8 and 3.8% of all leads, 2.7 and 7.1% of 182 right ventricular, 0.7 and 0% of 144 atrial leads, and in none of 14 coronary sinus leads. All leads implanted for <10 years were removed with a clinical success. Two patients were successfully operated after pericardial tamponade. There were no procedure-related deaths. Needle's Eye Snare lead extraction has a low complication rate. The technique should be considered as a primary tool for extraction of pacing leads, particularly atrial and coronary sinus pacing leads. The results for extracting ventricular leads might be improved if larger bore sheaths with a better cutting edge were available.Keywords
This publication has 10 references indexed in Scilit:
- Extraction of Old Pacemaker or Cardioverter-Defibrillator Leads by Laser Sheath Versus Femoral ApproachCirculation: Arrhythmia and Electrophysiology, 2010
- Lead Extraction in the Contemporary Setting: The LExICon StudyJACC, 2010
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leadsEuropean Heart Journal, 2008
- Lead extraction for device related infections: a single-centre experienceEP Europace, 2004
- Pacemaker Lead Extraction with the Needle's Eye Snare for Countertraction via a Femoral ApproachPacing and Clinical Electrophysiology, 2002
- Clinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United StatesPacing and Clinical Electrophysiology, 2002
- Learning Curve Characteristics of Pacing Lead Extraction with a Laser SheathPacing and Clinical Electrophysiology, 1998
- Five‐Years Experience with Intravascular Lead ExtractionPacing and Clinical Electrophysiology, 1994
- Intravascular Lead Extraction Using Locking Stylets and SheathsPacing and Clinical Electrophysiology, 1990