A Compact Calibratable Pulse Oximeter Based on Color Filters: Towards a Quantitative Analysis of Measurement Uncertainty
- 30 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (6) , 7522-7531
Abstract
Compact and low-cost opto-biomedical sensing systems today are ubiquitously available for measuring the oxygen saturation in blood. The oxygen saturation is derived by a complex, usually not well defined analytical process from the optical absorption of tissue at different wavelengths. The amount of information, which is originally contained in absorption measurements, is drastically reduced by this circumstance. However, the reliability of the analytical process as well as the influence of external parameters like blood pressures on the experimental uncertainty of such systems are widely unknown. Thus, to explore the experimental uncertainty quantitatively, original experimental data have to be used. In commercial systems, however, these data are usually not accessible. Therefore, test systems with full access to original absorption data are necessary. In this work, we develop and describe a test system consisting of color filters and a charge-coupled device (CCD) image sensor, which has substantial advantages in comparison to usually used systems based on multi-color light-emitting diodes (LEDs). Color filters with well-defined filter functions allow for a higher spectral resolution, and will finally guide the way to multi-spectral analysis of blood absorption measurements with reduced uncertainty.Keywords
Funding Information
- Metrology for Complex Nanosystems NanoMet
- LENAOptoSense
This publication has 36 references indexed in Scilit:
- Design and Evaluation of a Low-Cost Smartphone Pulse OximeterSensors, 2013
- Design of an Oximeter Based on LED-LED Configuration and FPGA TechnologySensors, 2013
- The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort studyBMC Emergency Medicine, 2010
- Impact of Pulse Oximetry Surveillance on Rescue Events and Intensive Care Unit TransfersAnesthesiology, 2010
- The dicrotic notch as alternative time-reference point to measure local pulse wave velocity in the carotid artery by means of ultrasonographyJournal Of Hypertension, 2009
- Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometryJournal of Biomedical Optics, 2006
- Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nmJournal of Physics D: Applied Physics, 2005
- The Pulse Oximetry Gap in Carbon Monoxide IntoxicationAnnals of Emergency Medicine, 1994
- Potential errors in pulse oximetryAnaesthesia, 1991
- Effect of anemia on pulse oximeter accuracy at low saturationJournal of Clinical Monitoring and Computing, 1990