Photoelastic Stress Analysis Error Quantification in Vasculature Models for Robot Feedback Control
Authors:
- 4 March 2010
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 15 (4) , 520-526
Abstract
Real-time and accurate stress calculation in walls of vasculature is a desired goal in order to provide feedback control for catheter insertion robots without changing catheter stiffness and lumen. This feedback source also has applications in endovascular surgery simulation. In order to address this need, we consider photoelastic effect, as birefringence produced by light retardation relates to the stress inside photoelastic materials. In this research, a polariscope was designed for urethane elastomer vasculature models, the photoelastic coefficient of urethane elastomer was measured, and a camera system was calibrated to quantify and reduce error in the measurement system. An average error of 3.9% was found in stress measurements for the pressure range of 60-189 mmHg inside the urethane elastomer model. This result was applied to correct stress distribution images, using the average stress value as a reference and preserving local maxima and minima of stress. This enabled us to accurately calculate stress in vasculature models during human blood pressure simulation (HBPS), and enables the comparison, in a closed loop, of stress produced by HBPS and by catheter motion when driven by a robot, as well as to measure the stress produced by medical tools on the vascular model wall.Keywords
This publication has 13 references indexed in Scilit:
- Human Blood Pressure Simulation for Stress Analysis in Model of Vasculature Using Photoelastic EffectInternational Journal of Automation Technology, 2009
- Patient-Specific IVR Endovascular Simulator with Augmented Reality for Medical Training and Robot EvaluationJournal of Robotics and Mechatronics, 2008
- Numerical evaluation method for catheter prototypes using photo-elastic stress analysis on patient-specific vascular modelThe International Journal of Medical Robotics and Computer Assisted Surgery, 2007
- Photoelastic Stress Analysis on Patient-Specific Anatomical Model of Cerebral Artery2007
- Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- The role of medical simulation: an overviewThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- An In Vitro Patient-Specific Biological Model of the Cerebral Artery Reproduced with a Membranous Configuration for Simulating Endovascular InterventionJournal of Robotics and Mechatronics, 2005
- Femoral surface strain in intact composite femurs: a custom computer analysis of the photoelastic coating techniqueIEEE Transactions on Biomedical Engineering, 2000
- Study on Micro Force Sensor for Minimum Invasive Surgery.TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 1998
- Alternative projections of mortality and disability by cause 1990–2020: Global Burden of Disease StudyThe Lancet, 1997