Impact of Glucose Meter Error on Glycemic Variability and Time in Target Range During Glycemic Control After Cardiovascular Surgery
Authors:
Open Access
- 25 August 2015
- journal article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 10 (2) , 336-342
Abstract
Background: We retrospectively studied the impact of glucose meter error on the efficacy of glycemic control after cardiovascular surgery. Method: Adult patients undergoing intravenous insulin glycemic control therapy after cardiovascular surgery, with 12-24 consecutive glucose meter measurements used to make insulin dosing decisions, had glucose values analyzed to determine glycemic variability by both standard deviation (SD) and continuous overall net glycemic action (CONGA), and percentage glucose values in target glucose range (110-150 mg/dL). Information was recorded for 70 patients during each of 2 periods, with different glucose meters used to measure glucose and dose insulin during each period but no other changes to the glycemic control protocol. Accuracy and precision of each meter were also compared using whole blood specimens from ICU patients. Results: Glucose meter 1 (GM1) had median bias of 11 mg/dL compared to a laboratory reference method, while glucose meter 2 (GM2) had a median bias of 1 mg/dL. GM1 and GM2 differed little in precision (CV = 2.0% and 2.7%, respectively). Compared to the period when GM1 was used to make insulin dosing decisions, patients whose insulin dose was managed by GM2 demonstrated reduced glycemic variability as measured by both SD (13.7 vs 21.6 mg/dL, P < .0001) and CONGA (13.5 vs 19.4 mg/dL, P < .0001) and increased percentage glucose values in target range (74.5 vs 66.7%, P = .002). Conclusions: Decreasing glucose meter error (bias) was associated with decreased glycemic variability and increased percentage of values in target glucose range for patients placed on intravenous insulin therapy following cardiovascular surgery.Keywords
This publication has 26 references indexed in Scilit:
- Empiric Validation of Simulation Models for Estimating Glucose Meter Performance Criteria for Moderate Levels of Glycemic ControlDiabetes Technology & Therapeutics, 2013
- Measures of Glycemic Variability and Links with Psychological FunctioningCurrent Diabetes Reports, 2010
- Glucose Meter Performance Criteria for Tight Glycemic Control Estimated by Simulation ModelingClinical Chemistry, 2010
- Intensive versus Conventional Glucose Control in Critically Ill PatientsNew England Journal of Medicine, 2009
- Chapter 16 Monte Carlo Simulation in Establishing Analytical Quality Requirements for Clinical Laboratory Tests2009
- Tight Glucose Control in the Intensive Care Unit: Are Glucose Meters up to the Task?Clinical Chemistry, 2009
- Evaluation of the Impact of Hematocrit and Other Interference on the Accuracy of Hospital-Based Glucose MetersDiabetes Technology & Therapeutics, 2008
- Accuracy of Roche Accu-Chek Inform Whole Blood Capillary, Arterial, and Venous Glucose Values in Patients Receiving Intensive Intravenous Insulin Therapy After Cardiac SurgeryAmerican Journal of Clinical Pathology, 2007
- Glucose Measurement: Confounding Issues in Setting Targets for Inpatient ManagementDiabetes Care, 2007
- Intensive Insulin Therapy in Critically Ill PatientsNew England Journal of Medicine, 2001