Comparison of treatment plans between IMRT with MR-linac and VMAT for lung SABR
Open Access
- 13 June 2019
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-8
Abstract
The aim of this study was to compare the plan quality of magnetic-resonance image-based intensity modulated radiation therapy (MRI-based-IMRT) with the MRIdian Linac system to that of volumetric modulated arc therapy (VMAT) with the TrueBeam STx system for lung stereotactic ablative radiotherapy (SABR). A total of 22 patients with tumors located in the lower lobe were retrospectively selected for the study. For each patient, both the MRI-based-IMRT and VMAT plans were generated using an identical CT image set and identical structures with the exception of the planning target volume (PTV). The PTVs of the MRI-based-IMRT were generated by adding an isotropic margin of 3 mm from the gross tumor volume, whereas those of VMAT were generated by adding an isotropic margin of 5 mm from the internal target volume. For both the MRI-based-IMRT and VMAT, the prescription doses to the PTVs were 60 Gy in four fractions. The average PTV volume of the MRI-based-IMRT was approximately 4-times smaller than that of VMAT (p < 0.001). The maximum dose to the bronchi for the MRI-based-IMRT was smaller than that for the VMAT (20.4 Gy versus 24.2 Gy, p < 0.001). In addition, V40Gy of the rib for the MRI-based-IMRT was smaller than that for the VMAT (1.8 cm3 versus 7.7 cm3, p = 0.008). However, the maximum doses to the skin and spinal cord for the MRI-based-IMRT (33.0 Gy and 14.5 Gy, respectively) were larger than those for the VMAT (27.8 Gy and 11.0 Gy, respectively) showing p values of less than 0.02. For the ipsilateral lung, the mean dose, V20Gy, V10Gy, and V5Gy for the MRI-based-IMRT were smaller than those for the VMAT (all with p < 0.05). For the contralateral lung, V5Gy, V10Gy, D1500cc, and D1000cc for the MRI-based-IMRT were larger than those for the VMAT (all with p < 0.05). The mean dose and V50% of the whole body for the MRI-based-IMRT were smaller than those for the VMAT (0.9 Gy versus 1.2 Gy, and 78.7 cm3 versus 103.5 cm3, respectively, all at p < 0.001). The MRI-based-IMRT using the MRIdian Linac system could reduce doses to bronchi, rib, ipsilateral lung, and whole body compared to VMAT for lung SABR when the tumor was located in the lower lobe.Keywords
Funding Information
- National Research Foundation of Korea (2017M2A2A7A02020640, 2017M2A2A7A02020641, 2017M2A2A7A02020643)
This publication has 15 references indexed in Scilit:
- Dosimetric analysis of stereotactic body radiation therapy for pancreatic cancer using MR-guided Tri-60Co unit, MR-guided LINAC, and conventional LINAC-based plansPractical Radiation Oncology, 2018
- Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABRBritish Journal of Radiology, 2016
- A comparative planning study for lung SABR between tri-Co-60 magnetic resonance image guided radiation therapy system and volumetric modulated arc therapyRadiotherapy and Oncology, 2016
- The effect of extremely narrow MLC leaf width on the plan quality of VMAT for prostate cancerRadiation Oncology, 2016
- A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based stereotactic body radiotherapy for central early-stage non−small cell lung cancerMedical Dosimetry, 2016
- Feasibility of magnetic resonance imaging–guided liver stereotactic body radiation therapy: A comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based intensity modulated radiation therapyPractical Radiation Oncology, 2015
- Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a 60 Co Magnetic Resonance Image Guidance Radiation Therapy SystemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plansJournal of Medical Physics, 2014
- Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancerRadiation Oncology Journal, 2013
- Influence of MLC leaf width on biologically adapted IMRT plansActa Oncologica, 2010