Zhengqi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhengqi Li has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
Zhichao Chen
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
20 shared publicationsQunyi Zhu
Harbin Institute of Technology
14 shared publications- Zhichao Chen
School of Energy Science and Engineering, Harbin Institute of Technology, 92, West Dazhi Street, Harbin, 150001, PR China
10 shared publications Feng Ren
School of Energy Science and Engineering, Harbin Institute of Technology , Harbin , P. R. China
8 shared publicationsChunlong Liu
Harbin Institute of Technology
6 shared publicationsGuangkui Liu
Harbin Institute of Technology
6 shared publications
Latest Publications
- 14 August 2026
- Published by Taylor & Francis in Combustion Science and Technology
- p. 1-32
Application of a Novel Strong Flame-Stabilizing Swirl Technology in a 350 MW Supercritical Boiler: Gas–Solid Flow, Combustion Characteristics, and NO x Emissions
In the past several years, China’s installed renewable energy capacity has grown steadily, and the rapid development of renewables such as wind and solar power has imposed greater requirements on t...
- 14 August 2026
- Published by Taylor & Francis in Combustion Science and Technology
- p. 1-32
Application of a Novel Strong Flame-Stabilizing Swirl Technology in a 350 MW Supercritical Boiler: Gas–Solid Flow, Combustion Characteristics, and NO x Emissions
In the past several years, China’s installed renewable energy capacity has grown steadily, and the rapid development of renewables such as wind and solar power has imposed greater requirements on t...
- 20 November 2025
- Published by Elsevier in Waste Management
- Vol. 210, 115251
The physicochemical properties, thermal conversion performance, and kinetic characteristics of pressurized pulverized coal gasification slag
- 20 November 2025
- Published by Elsevier in Waste Management
- Vol. 210, 115251
The physicochemical properties, thermal conversion performance, and kinetic characteristics of pressurized pulverized coal gasification slag
- Open Access
Experimental Study on Gas Particle Flow Characteristics of a Novel Stable Combustion Burner Under Different Primary Air Velocities
Existing faulty coal-fired units generally achieve oil-free stable combustion only at loads over 30%, failing to meet low load regulation demands. To address the insufficient flexibility of boilers, a novel flame-stabilization theory was developed for retrofitting a 350 MW faulty coal-fired unit boiler. Based on the actual burner dimensions of the 350 MW unit boiler, a geometric scaling ratio of 1:7 between model and actual burners was established. Phase Doppler Anemometry (PDA) was employed to conduct gas particle flow experiments on the model burner, revealing the impact of different primary air velocities on the gas particle flow characteristics of the novel stabilized flow burner. The analysis of experimental results suggests that, When the primary air velocity is 9 m/s, a central recirculation zone forms at the burner outlet. At a primary air velocity of 10 m/s, an annular recirculation zone develops with a relatively large coverage area. When the primary air velocity increases to 11 m/s, the extent of the annular recirculation zone diminishes. At a primary air velocity of 10 m/s, an extensive annular recirculation zone forms at the burner outlet, which appears to provide sufficient energy for the ignition of pulverized coal. Elevated pulverized coal concentration near the burner centerline facilitates the formation of a high-temperature oxygen-lean reducing atmosphere, suppressing fuel-based NOx generation. Therefore, it is recommended to set the actual operating parameters of the novel stabilized flow burner based on the 10 m/s primary air velocity condition in the gas particle flow experiments.
Open AccessExperimental Study on Gas Particle Flow Characteristics of a Novel Stable Combustion Burner Under Different Primary Air Velocities
Existing faulty coal-fired units generally achieve oil-free stable combustion only at loads over 30%, failing to meet low load regulation demands. To address the insufficient flexibility of boilers, a novel flame-stabilization theory was developed for retrofitting a 350 MW faulty coal-fired unit boiler. Based on the actual burner dimensions of the 350 MW unit boiler, a geometric scaling ratio of 1:7 between model and actual burners was established. Phase Doppler Anemometry (PDA) was employed to conduct gas particle flow experiments on the model burner, revealing the impact of different primary air velocities on the gas particle flow characteristics of the novel stabilized flow burner. The analysis of experimental results suggests that, When the primary air velocity is 9 m/s, a central recirculation zone forms at the burner outlet. At a primary air velocity of 10 m/s, an annular recirculation zone develops with a relatively large coverage area. When the primary air velocity increases to 11 m/s, the extent of the annular recirculation zone diminishes. At a primary air velocity of 10 m/s, an extensive annular recirculation zone forms at the burner outlet, which appears to provide sufficient energy for the ignition of pulverized coal. Elevated pulverized coal concentration near the burner centerline facilitates the formation of a high-temperature oxygen-lean reducing atmosphere, suppressing fuel-based NOx generation. Therefore, it is recommended to set the actual operating parameters of the novel stabilized flow burner based on the 10 m/s primary air velocity condition in the gas particle flow experiments.
- 15 March 2025
- Published by Springer Nature in Frontiers in Energy
- Vol. 19 (5) , 738-756
Gas-particle flow and rapid load-up characteristics of a novel deep peak regulation burner
- 15 March 2025
- Published by Springer Nature in Frontiers in Energy
- Vol. 19 (5) , 738-756
Gas-particle flow and rapid load-up characteristics of a novel deep peak regulation burner
- 24 January 2024
- Published by Elsevier in Environmental Research
- Vol. 248, 118311
Adsorption performance of mineral-carbon adsorbents derived from coal gasification fine ash: Prepared via low-temperature alkali fusion method
- 24 January 2024
- Published by Elsevier in Environmental Research
- Vol. 248, 118311
Adsorption performance of mineral-carbon adsorbents derived from coal gasification fine ash: Prepared via low-temperature alkali fusion method
- 3 August 2023
- Published by Elsevier in Environmental Research
- Vol. 236 (Pt 2) , 116802
Sustainable preparation of high-calorific value and low-N and S energy products through the low-temperature alkali fusion of coal gasification fine ash
- 3 August 2023
- Published by Elsevier in Environmental Research
- Vol. 236 (Pt 2) , 116802
Sustainable preparation of high-calorific value and low-N and S energy products through the low-temperature alkali fusion of coal gasification fine ash
- Open Access
Influence of Central Air on Flow and Combustion Characteristics and Low-Load Stabilization Performance of a Babcock Burner
On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.
Open AccessInfluence of Central Air on Flow and Combustion Characteristics and Low-Load Stabilization Performance of a Babcock Burner
On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.
- 8 September 2022
- Published by Walter de Gruyter GmbH in International Journal of Chemical Reactor Engineering
- Vol. 21 (5) , 591-603
Experimental study on the influence of fuel-rich and fuel-lean coal/airflow ratio on aerodynamic characteristics of a 300MWe foster wheeler down-fired boiler
To address the problem of late ignition and poor burnout of Foster-Wheeler down-fired boilers, this study proposed a new combustion technology, which combines adding on arch secondary air and alternately arranging the fuel-lean coal/airflow (FLCA) and fuel-rich coal/airflow (FRCA). The coal particle trajectories of FLCA and FRCA and overall aerodynamic characteristics in the furnace were studied at FRCA and FLCA ratio ( R RL ) of 5:5, 7:3, and 9:1. The results showed that even at a low FRCA ratio, the new combustion technology could still effectively ensure the penetration depth of pulverised coal/airflow. At different R RL values, the main airflow from the arch appeared in the near-wall area and could penetrate downwards into the cold ash hopper area. With an increase in the value of R RL , the deflection degree of FLCA towards the furnace wall increased, while that of FRCA decreased. At R RL of 7:3, both the penetration depth and deflection degree of FRCA and FLCA were at a high level, which was conductive to promoting the burnout and recommended in practical applications.
- 8 September 2022
- Published by Walter de Gruyter GmbH in International Journal of Chemical Reactor Engineering
- Vol. 21 (5) , 591-603
Experimental study on the influence of fuel-rich and fuel-lean coal/airflow ratio on aerodynamic characteristics of a 300MWe foster wheeler down-fired boiler
To address the problem of late ignition and poor burnout of Foster-Wheeler down-fired boilers, this study proposed a new combustion technology, which combines adding on arch secondary air and alternately arranging the fuel-lean coal/airflow (FLCA) and fuel-rich coal/airflow (FRCA). The coal particle trajectories of FLCA and FRCA and overall aerodynamic characteristics in the furnace were studied at FRCA and FLCA ratio ( R RL ) of 5:5, 7:3, and 9:1. The results showed that even at a low FRCA ratio, the new combustion technology could still effectively ensure the penetration depth of pulverised coal/airflow. At different R RL values, the main airflow from the arch appeared in the near-wall area and could penetrate downwards into the cold ash hopper area. With an increase in the value of R RL , the deflection degree of FLCA towards the furnace wall increased, while that of FRCA decreased. At R RL of 7:3, both the penetration depth and deflection degree of FRCA and FLCA were at a high level, which was conductive to promoting the burnout and recommended in practical applications.
- 6 September 2022
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 17 (6)
Influence of the parallel oil‐secondary air and F‐layer secondary air distribution on the flow, combustion, and NOx generation characteristics of FW down‐fired boilers retrofitted with a stable combustion technology
To further reduce the NOx emissions of the down‐fired boiler while improving its low‐load stable combustion capacity, a new low NOx combustion organization mode that utilizes the high velocity parallel oil‐secondary air to improve the pulverized coal combustion process was proposed based on a novel stable combustion technology. We carried out cold airflow experiments under different oil‐secondary air and F‐layer secondary air distributions (mass flow rate ratios of 1:9, 1:3, 2:3) based on a 300 MWe Foster Wheeler down‐fired boiler to study its influence on the flow and mixing characteristics of the coal/airflow. Results show that the mixing between the oil‐secondary air and the fuel‐rich coal/airflow is gradually delayed with the increase of the secondary air distribution. When the secondary air distribution reaches more than 2:3, the oil‐secondary air starts to become the dominant airflow that influences the whole flow field in the furnace. Based on the result of the cold airflow experiment, we carried out industrial measurements under different parallel oil‐secondary air and F‐layer secondary air distributions (4:6, 5:5, 6:4) on a 600 MWe FW down‐fired boiler under the condition of using the high velocity oil‐secondary air. The ignition distance of the fuel‐rich coal/airflow, the flue gas temperature, the O2, CO, and NOx concentrations in the furnace were measured. At the secondary air distribution of 4:6, the ignition distance of the fuel‐rich coal/airflow was about 1.31 m. When the secondary air distribution was increased to 5:5 and 6:4, the ignition was put off, but the pulverized coal/airflow could still catch on fire in time. With the increase of the parallel oil‐secondary air proportion, the flame center in the furnace did not move downward substantially. In three cases, the lowest O2 concentrations in the inspection port area under the burner were all below 1% (peak CO concentration values were all above 28,000 ppm). The pulverized coal all burned in a strong reducing atmosphere. At secondary air distributions of 4:6, 5:5, and 6:4, NOx emissions of the boiler were, respectively, 825.83, 819.48, and 853.86 mg/Nm3 (O2 = 6%). The thermal efficiency was, respectively, 90.09%, 89.16%, and 90.98%. In actual operation, the recommended secondary air distribution is 6:4.
- 6 September 2022
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 17 (6)
Influence of the parallel oil‐secondary air and F‐layer secondary air distribution on the flow, combustion, and NOx generation characteristics of FW down‐fired boilers retrofitted with a stable combustion technology
To further reduce the NOx emissions of the down‐fired boiler while improving its low‐load stable combustion capacity, a new low NOx combustion organization mode that utilizes the high velocity parallel oil‐secondary air to improve the pulverized coal combustion process was proposed based on a novel stable combustion technology. We carried out cold airflow experiments under different oil‐secondary air and F‐layer secondary air distributions (mass flow rate ratios of 1:9, 1:3, 2:3) based on a 300 MWe Foster Wheeler down‐fired boiler to study its influence on the flow and mixing characteristics of the coal/airflow. Results show that the mixing between the oil‐secondary air and the fuel‐rich coal/airflow is gradually delayed with the increase of the secondary air distribution. When the secondary air distribution reaches more than 2:3, the oil‐secondary air starts to become the dominant airflow that influences the whole flow field in the furnace. Based on the result of the cold airflow experiment, we carried out industrial measurements under different parallel oil‐secondary air and F‐layer secondary air distributions (4:6, 5:5, 6:4) on a 600 MWe FW down‐fired boiler under the condition of using the high velocity oil‐secondary air. The ignition distance of the fuel‐rich coal/airflow, the flue gas temperature, the O2, CO, and NOx concentrations in the furnace were measured. At the secondary air distribution of 4:6, the ignition distance of the fuel‐rich coal/airflow was about 1.31 m. When the secondary air distribution was increased to 5:5 and 6:4, the ignition was put off, but the pulverized coal/airflow could still catch on fire in time. With the increase of the parallel oil‐secondary air proportion, the flame center in the furnace did not move downward substantially. In three cases, the lowest O2 concentrations in the inspection port area under the burner were all below 1% (peak CO concentration values were all above 28,000 ppm). The pulverized coal all burned in a strong reducing atmosphere. At secondary air distributions of 4:6, 5:5, and 6:4, NOx emissions of the boiler were, respectively, 825.83, 819.48, and 853.86 mg/Nm3 (O2 = 6%). The thermal efficiency was, respectively, 90.09%, 89.16%, and 90.98%. In actual operation, the recommended secondary air distribution is 6:4.
- 5 September 2022
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 196 (10) , 1529-1553
Influence of the Parallel C-Layer Secondary Air on Flow, Combustion and Nox Generation Characteristics of a 600mwe FW Down-Fired Boiler Retrofitted with a Stable Combustion Organization Mode
To improve the low-load stable combustion capacity of a low-grade coal-fired boiler, this study proposed to reform C-layer secondary air, which was then used to improve the ignition and combustion stability of coal/airflow of a 600 MWe Foster Wheeler down-fired boiler. Cold airflow experiments and industrial measurements were carried out to investigate the influence of the new C-layer secondary air on the aerodynamic and combustion characteristics at low load under different C-layer secondary air ratios and damper openings, respectively. The flow and mixing characteristics of the C-layer secondary air and coal/airflow, the flue gas temperature and NOx, O2, and CO concentration distributions in the furnace at low load were examined. With increase in the C-layer secondary air ratio, the flow range of coal/airflow gradually expanded. The mixing distance first increased and then decreased. At an air ratio of 25%, the mixing distance was the longest. Industrial measurements showed that compared with that at the C-layer secondary air damper opening of 0%, the coal/airflow ignited earlier at 40% (corresponding to the C-layer secondary air ratio of 23.73%), and the flue gas temperature in the furnace increased substantially. At C-layer secondary air damper opening of 0%, 20%, and 40%, carbon content in the fly ash was 4.62%, 5.32%, and 4.20%, respectively. The respective NOx emissions at the furnace exits were 450 mg/Nm3, 378 mg/Nm3, and 427 mg/Nm3, (O2 = 6%). In actual operation, 40% is recommended as the optimal C-layer secondary air damper opening.
- 5 September 2022
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 196 (10) , 1529-1553
Influence of the Parallel C-Layer Secondary Air on Flow, Combustion and Nox Generation Characteristics of a 600mwe FW Down-Fired Boiler Retrofitted with a Stable Combustion Organization Mode
To improve the low-load stable combustion capacity of a low-grade coal-fired boiler, this study proposed to reform C-layer secondary air, which was then used to improve the ignition and combustion stability of coal/airflow of a 600 MWe Foster Wheeler down-fired boiler. Cold airflow experiments and industrial measurements were carried out to investigate the influence of the new C-layer secondary air on the aerodynamic and combustion characteristics at low load under different C-layer secondary air ratios and damper openings, respectively. The flow and mixing characteristics of the C-layer secondary air and coal/airflow, the flue gas temperature and NOx, O2, and CO concentration distributions in the furnace at low load were examined. With increase in the C-layer secondary air ratio, the flow range of coal/airflow gradually expanded. The mixing distance first increased and then decreased. At an air ratio of 25%, the mixing distance was the longest. Industrial measurements showed that compared with that at the C-layer secondary air damper opening of 0%, the coal/airflow ignited earlier at 40% (corresponding to the C-layer secondary air ratio of 23.73%), and the flue gas temperature in the furnace increased substantially. At C-layer secondary air damper opening of 0%, 20%, and 40%, carbon content in the fly ash was 4.62%, 5.32%, and 4.20%, respectively. The respective NOx emissions at the furnace exits were 450 mg/Nm3, 378 mg/Nm3, and 427 mg/Nm3, (O2 = 6%). In actual operation, 40% is recommended as the optimal C-layer secondary air damper opening.