Morse taper implant macrodesign, loading protocol and site of installation – retrospective study of 5,601 implants
Open Access
- 1 January 2019
- journal article
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Abstract
Introduction The long-term implant-supported prosthetic rehabilitation monitoring is extremely important in evaluating parameters that could interfere in the success of the treatment. Objective To evaluate the influence of macrodesign (shape of the body and apex), length and diameter, insertion torque, site of installation as well as the loading protocol, on long-term survival rates. Material and method The data obtained was from the medical records of rehabilitated patients who had had at least one Morse taper implant surgery done at ILAPEO School between 2006 -2012. Incomplete medical records, from which it would have been impossible to extract all data essential to complete the study, were excluded. Result A total of 1,142 patient’s medical records comprised the sample; documenting the progress of 5,601 implants, done in both jaws and mandibles. The final survival rate was 98.31%, over an average time of 37.54 months. The type of implant most used was cylindrical (70.33%). The mean installation torque most evidenced in the study was between 41 and 50 Ncm. A logistical regression analysis showed that none of the following variables, site of installation, body and apex shape designs and length, had any significant statistical influence on implant loss. Torque increase and diameter influenced implant loss while immediate loading favored implant maintenance. Conclusion It can be concluded that Morse taper implants present a long-term survival rate that can be lowered by excessive torque, as well as by the diameter of the implant.Keywords
This publication has 30 references indexed in Scilit:
- Effect of double conical abutment screw on implant preloadClinical Oral Implants Research, 2015
- The Bacterial Sealing Capacity of Morse Taper Implant–Abutment Systems in VitroJournal of Periodontology, 2015
- Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coatingThe Journal of Advanced Prosthodontics, 2015
- Detorque Evaluation of Dental Abutment Screws after Immersion in a Fluoridated Artificial Saliva SolutionJournal of Prosthodontics, 2012
- A longitudinal study of the survival of All-on-4 implants in the mandible with up to 10 years of follow-upThe Journal of the American Dental Association, 2011
- A review of dental implants and infectionJournal of Hospital Infection, 2009
- Dealing with dental implant failuresJournal of Applied Oral Science, 2008
- A long‐term follow‐up of 76 Brånemark single‐tooth implantsClinical Oral Implants Research, 2002
- Tilted Implants as an Alternative to Maxillary Sinus Grafting: A Clinical, Radiologic, and Periotest StudyClinical Implant Dentistry and Related Research, 2001
- Intra-Osseous Anchorage of Dental Prostheses:I. Experimental StudiesScandinavian Journal of Plastic and Reconstructive Surgery, 1969