Abstract
X-Ray Simulation Analysis (XRSA) is an analytical ray-tracing mixed code developed specifically for the ITER Core X-Ray Crystal Spectroscopy (XRCS-Core) diagnostic, which employs a dual-reflection configuration incorporating multiple pre-reflectors made of Highly Oriented Pyrolytic Graphite (HOPG) and spherically curved analyzing crystals. The ITER XRCS-Core is designed for high spectral resolution measurement in specific wavelength ranges, including narrow bands around 1.354 Å for W64+, 2.19 Å for Xe51+, and 2.555 Å for Xe44+ and Xe47+, enabling diagnostic capability across a broad electron temperature range in the ITER plasma. XRSA facilitates efficient simulation of the spectral performance of this complex X-ray spectroscopic system. Recent updates to the XRSA code have incorporated two critical effects: auto-focusing, which specifically applies to HOPG, and polarization. These two effects are particularly important in the dual-reflection configuration used in the ITER XRCS-Core system to provide more accurate modeling results. Simulations conducted with the updated code demonstrate that polarization has a substantial impact on the performance of the dual-reflection system. Additionally, the combined influence of polarization and system layout introduces performance variations across channels through the same crystal.Keywords
Funding Information
- National Natural Science Foundation of China (12475222, 12205122, 51821005)
- Hubei International Science and Technology Cooperation Projects (2022EHB003)
This publication has 15 references indexed in Scilit:
- X-ray imaging crystal spectrometer (XICS) diagnostic on the HL-3 tokamakFusion Engineering and Design, 2024
- Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracingReview of Scientific Instruments, 2024
- Novel dual-reflection design applied for ITER core x-ray spectrometerReview of Scientific Instruments, 2022
- Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition FacilityReview of Scientific Instruments, 2021
- Energetic particle physics in fusion research in preparation for burning plasma experimentsNuclear Fusion, 2014
- Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical deviceReview of Scientific Instruments, 2010
- A high-resolution soft x-ray spectrometer on the MAST tokamakReview of Scientific Instruments, 2004
- X-Ray Spectrometry Systems for ITER1998
- A conceptual model for ray tracing calculations with mosaic crystalsReview of Scientific Instruments, 1992
- Tokamak Fusion Test Reactor horizontal high-resolution Bragg x-ray spectrometerReview of Scientific Instruments, 1985