A New, Non-Invasive in vivo Optical Blood Glucose Measurement Technique Using Near-Infrared Radiation (“Pulse Glucometry”) and a Proposal for “Pulse Hemo-Photometry” Blood Constituent Measurements
- 28 September 2012
- book chapter
- Published by IGI Global Scientific Publishing
- p. 18-26
Abstract
A recently proposed optical method for a non-invasive in vivo blood glucose level (BGL) measurement named “pulse glucometry” is introduced. This method is based on near-infrared living body spectroscopy to accurately obtain blood information. The remarkable feature of the method is the measurement of both the total transmitted radiation spectra in wavelength ? (I?) and the cardiac-related pulsatile component (?I?). When ?I? is superimposed on I?, the differential optical density (?OD?), which includes only arterial blood information, is obtained, thus avoiding interference from living tissues other than arterial blood. Another feature is the ability to measure the differential optical density (?OD?) in multiple wavelengths to avoid interference from blood constituents other than the target blood chemical (glucose). To support this methodology, a very fast near-infrared spectroscopic system was developed to obtain a photoplethysmographic cardiac signal with a resolution of 8 nm over a wavelength range of 900 to 1700 nm at a 100 Hz sampling frequency. An example of an in vivo BGL measurement is shown and indicates good prediction capabilities. This method can be expanded to the measurement of other blood constituents.Keywords
This publication has 15 references indexed in Scilit:
- Multivariate Regression and Classification Models for Estimation of Blood Glucose Levels Using a New Non-invasive Optical Measurement Technique Named “Pulse-GlucometryThe Open Optics Journal, 2009
- Pendra goes Dutch; lessons for the CE mark in EuropeDiabetes Research and Clinical Practice, 2006
- Non-invasive glucose monitoring in patients with diabetes: A novel system based on impedance spectroscopyBiosensors and Bioelectronics, 2006
- Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometryJournal of Biomedical Optics, 2006
- ‘Urine testing is a waste of time’: newly diagnosed Type 2 diabetes patients’ perceptions of self‐monitoringDiabetic Medicine, 2004
- Constrained optimization of Drude’s equations eliminates effects of confounding molecules for the polarimetric measurement of glucoseJournal of Biomedical Optics, 2004
- Use of the GlucoWatch® biographer in children and adolescents with diabetesPediatric Diabetes, 2002
- Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infraredOptics Letters, 1994
- Noninvasive Blood Glucose Assay by Near-Infrared Diffuse Reflectance Spectroscopy of the Human Inner LipApplied Spectroscopy, 1993
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987