Abstract
VCO-based ADCs widely utilize coarse-fine readout to save power and hardware compared to counter-only converters. However, the timing mismatch due to the clock skew between the coarse and fine quantizers can lead to significant reconstruction errors. This paper proposes a digital calibration circuit to detect and correct coarse-fine timing mismatch for VCO-based ADCs. The circuit includes overcount/undercount logic to detect all possible timing mismatch cases and generates a correction value to digitally remove the errors. The calibration operates continuously in the background and is entirely digital, making it scaling-friendly and robust against analog imperfections. Simulations show that a VCO-based ADC utilizing the calibration circuit improves the SNR by 10.3 dB and 6.9 dB versus a conventional coarse-fine converter and one with a conventional retiming calibration, respectively.
Funding Information
  • National Aeronautics and Space Administration
  • National Science and Technology Council, Taiwan (NSTC 111-2221-E-A49-150, NSTC 112-2622-8-A49-013-SB)