Background The risks associated with radiation exposure are higher in children than in adults. Therefore the use of fluoroscopy in common pediatric examinations such as voiding cystourethrography (VCUG) requires accurate determination of the associated effective dose. Objective To estimate effective dose for VCUG examinations performed in children younger than 10 years using anthropomorphic phantoms and metal oxide semiconductor field-effect transistor (MOSFET) dosimeters. Materials and methods MOSFETs were placed within four phantoms representing children ≤10 years old, at locations corresponding to radiosensitive organs, and exposed to a mock VCUG (5 min of fluoroscopy, 50 spot exposures) to minimize measurement error. Effective dose was measured and scaled to a standardized clinical VCUG (1 min fluoroscopy, 5 spot exposures) determined from patient logs. Monte Carlo simulations were performed to assess the accuracy of the measured effective dose. The dose area product (DAP) from each VCUG was compared to the effective dose. Results Effective doses ranged from 0.10 to 0.55 mSv, increased with age, and were higher in girls. Fluoroscopy accounted for 88–90% of the total effective dose, and spot exposures 10–12%. MOSFET-measured and simulation-derived effective doses were comparable (T > 0.12). DAP was strongly correlated with effective dose for both genders (r 2>0.97, P < 0.0001). Conclusion Effective doses for VCUG examinations performed in children ≤10 years of age are low but not negligible.Keywords
This publication has 22 references indexed in Scilit:
- Radiation dose measurement and risk estimation for paediatric patients undergoing micturating cystourethrographyBritish Journal of Radiology, 2007
- Fluoroscopy-controlled voiding cystourethrography in infants and children: Are the radiation risks trivial?European Radiology, 2005
- Radiation doses to paediatric patients up to 5 years of age undergoing micturating cystourethrography examinations and its dependence on patient age: a Monte Carlo studyBritish Journal of Radiology, 2003
- Paediatric fluoroscopy - a survey of children's hospitals in EuropePediatric Radiology, 2001
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001
- Radiation burden to paediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital.British Journal of Radiology, 1999
- Organ Dose Calculation in Medical X Ray Examinations by the Program PCXMCRadiation Protection Dosimetry, 1998
- Reduction of radiation dose in pediatric patients using pulsed fluoroscopy.American Journal of Roentgenology, 1996
- A phantom based method for deriving typical patient doses from measurements of dose–area product on populations of patientsBritish Journal of Radiology, 1995
- The radiation dose to children from X-ray examinations of the pelvis and the urinary tractBritish Journal of Radiology, 1995