Dhayananth Kanagarajan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dhayananth Kanagarajan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Geoffrey D. Tansley
School of Engineering and Built Environment, Griffith University, Gold Coast, Queensland, Australia
2 shared publications- Jo P. Pauls
School of Engineering and Built Environment, Griffith University, Gold Coast, Queensland, Australia
2 shared publications - Silver Heinsar
Department of Cardiology, Institute of Clinical Medicine, University of Tartu, L. Puusepa 8, 50406 Tartu, Estonia
2 shared publications - Albert Chong
National University of Singapore
1 shared publication - Arunn Narasimhan
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering Indian Institute of Technology Madras Chennai Tamil Nadu India
1 shared publication Clayton Semenzin
School of Engineering and Built Environment Griffith University Gold Coast Queensland Australia
1 shared publication
Latest Publications
- 29 September 2025
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (10) , 814-822
In Silico Analysis of Pulsatile Flow Veno-Arterial Extracorporeal Membrane Oxygenation on Human Aorta Model
Electrocardiogram (ECG)—synchronized pulsatile veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is a recent development in extracorporeal therapy for patients with severe cardiogenic shock. Although preclinical studies have shown benefits of pulsatile flow relative to continuous ECMO flow, none have explored the effects of the timing of ECMO pulses with respect to the cardiac cycle and its possible implications on ECMO complications. This study aimed to develop a computational fluid dynamics (CFD) model of V-A ECMO in a patient-specific human aorta and evaluate the effect of ECMO timing on cardiac unloading, surplus hemodynamic energy delivery, and mixing zone position. Using direct flow measurements from cardiogenic shock patients and an ECMO device, the model revealed that maximal left ventricular (LV) unloading occurred when the ECMO pulse was in early diastole (35–40% from LV peak systolic flow). Maximum surplus hemodynamic energy transmission to aortic branches occurred at 20% from LV peak systolic flow. This indicates a trade-off between heart afterload and hemodynamic energy delivery in selecting ECMO pulse timing. The mixing zone was primarily located in the aortic arch across timing configurations. Therefore, selecting ECMO pulse timing is crucial to maximizing the benefits of pulsatile flow in V-A ECMO treatment.
- 29 September 2025
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (10) , 814-822
In Silico Analysis of Pulsatile Flow Veno-Arterial Extracorporeal Membrane Oxygenation on Human Aorta Model
Electrocardiogram (ECG)—synchronized pulsatile veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is a recent development in extracorporeal therapy for patients with severe cardiogenic shock. Although preclinical studies have shown benefits of pulsatile flow relative to continuous ECMO flow, none have explored the effects of the timing of ECMO pulses with respect to the cardiac cycle and its possible implications on ECMO complications. This study aimed to develop a computational fluid dynamics (CFD) model of V-A ECMO in a patient-specific human aorta and evaluate the effect of ECMO timing on cardiac unloading, surplus hemodynamic energy delivery, and mixing zone position. Using direct flow measurements from cardiogenic shock patients and an ECMO device, the model revealed that maximal left ventricular (LV) unloading occurred when the ECMO pulse was in early diastole (35–40% from LV peak systolic flow). Maximum surplus hemodynamic energy transmission to aortic branches occurred at 20% from LV peak systolic flow. This indicates a trade-off between heart afterload and hemodynamic energy delivery in selecting ECMO pulse timing. The mixing zone was primarily located in the aortic arch across timing configurations. Therefore, selecting ECMO pulse timing is crucial to maximizing the benefits of pulsatile flow in V-A ECMO treatment.
- Open Access
- 24 September 2025
- Published by Springer Nature in Research Square
A Systematic Review of Pneumatic Compression Systems: Identifying Safe Cuff Pressures and Inflation Durations for Clinical and Biomedical Applications
Pneumatic compression devices are used across therapeutic, diagnostic, surgical, and sports medicine applications to improve vascular function, lymphatic drainage, and circulation. However, there is a lack of consolidated guidance on safe and effective cuff pressures and inflation durations, which are critical parameters for both clinical safety and device design. This systematic review aims to identify and summarize the pressure levels and inflation cycles employed in peer-reviewed studies, providing valuable insights for biomedical engineers and clinicians developing and using such technologies. A comprehensive literature search was conducted in PubMed, Scopus, and ScienceDirect for articles published between 2000 and March 2025. Of 12,375 articles identified, 120 studies met the eligibility criteria. Data were extracted on device type, anatomical location, pressure settings, inflation/deflation durations, and clinical context. Findings revealed a wide variability in pressure settings across applications, with therapeutic devices employing pressures ranging from 30 to 120 mmHg, while surgical tourniquets exceeded 200 mmHg. Inflation durations ranged from a few seconds to 45 minutes depending on the context. Despite widespread use, few studies referenced standardized safety thresholds. This review highlights the urgent need for harmonized pressure-duration guidelines and serves as a reference point for engineers designing next-generation pneumatic compression systems.
- 24 September 2025
- Published by Springer Nature in Research Square
Open AccessA Systematic Review of Pneumatic Compression Systems: Identifying Safe Cuff Pressures and Inflation Durations for Clinical and Biomedical Applications
Pneumatic compression devices are used across therapeutic, diagnostic, surgical, and sports medicine applications to improve vascular function, lymphatic drainage, and circulation. However, there is a lack of consolidated guidance on safe and effective cuff pressures and inflation durations, which are critical parameters for both clinical safety and device design. This systematic review aims to identify and summarize the pressure levels and inflation cycles employed in peer-reviewed studies, providing valuable insights for biomedical engineers and clinicians developing and using such technologies. A comprehensive literature search was conducted in PubMed, Scopus, and ScienceDirect for articles published between 2000 and March 2025. Of 12,375 articles identified, 120 studies met the eligibility criteria. Data were extracted on device type, anatomical location, pressure settings, inflation/deflation durations, and clinical context. Findings revealed a wide variability in pressure settings across applications, with therapeutic devices employing pressures ranging from 30 to 120 mmHg, while surgical tourniquets exceeded 200 mmHg. Inflation durations ranged from a few seconds to 45 minutes depending on the context. Despite widespread use, few studies referenced standardized safety thresholds. This review highlights the urgent need for harmonized pressure-duration guidelines and serves as a reference point for engineers designing next-generation pneumatic compression systems.
- 5 July 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (10) , 1558-1570
Visualizing Flow Dynamics in a Human Aorta During Peripheral Veno‐Arterial Extracorporeal Membrane Oxygenation Treatment Through Particle Image Velocimetry Study
Purpose: To build a mock circulatory loop to simulate veno‐arterial extracorporeal membrane oxygenation (V‐A ECMO) haemodynamics using a patient‐specific silicone aortic phantom and compare the flow dynamics for continuous and pulsatile ECMO settings. Methods: A silicone model of a human aorta with major branches was fabricated and the left iliac artery was cannulated using a Xenios ECMO device to simulate a peripheral V‐A ECMO configuration. The left ventricular outflows at the aortic root were simulated using a piston pump. Particle image velocimetry (PIV) experiments were conducted to measure flow velocities along the aortic phantom for a severe heart failure condition (LV = 1 L/min) supported by ECMO (4 L/min) at a heart rate of 80 bpm. Results: Comparing all ECMO support modes, counter pulse ECMO mode exhibited higher velocities during both peak systolic and mid‐diastolic phases. This shows that the LV and ECMO device supplied fluid into the aorta with less flow resistance, whereas other modes exhibited higher flow resistance due to the flow collision of antegrade LV and retrograde ECMO flow in the aorta. Conclusion: Pulsatile flow ECMO with better placement of ECMO pulse delivery in the cardiac cycle could develop greater pulsatility into the aorta, which is crucial for transferring haemodynamic energy and reducing cardiac afterload.
- 5 July 2025
- Published by Wiley in Artificial Organs
- Vol. 49 (10) , 1558-1570
Visualizing Flow Dynamics in a Human Aorta During Peripheral Veno‐Arterial Extracorporeal Membrane Oxygenation Treatment Through Particle Image Velocimetry Study
Purpose: To build a mock circulatory loop to simulate veno‐arterial extracorporeal membrane oxygenation (V‐A ECMO) haemodynamics using a patient‐specific silicone aortic phantom and compare the flow dynamics for continuous and pulsatile ECMO settings. Methods: A silicone model of a human aorta with major branches was fabricated and the left iliac artery was cannulated using a Xenios ECMO device to simulate a peripheral V‐A ECMO configuration. The left ventricular outflows at the aortic root were simulated using a piston pump. Particle image velocimetry (PIV) experiments were conducted to measure flow velocities along the aortic phantom for a severe heart failure condition (LV = 1 L/min) supported by ECMO (4 L/min) at a heart rate of 80 bpm. Results: Comparing all ECMO support modes, counter pulse ECMO mode exhibited higher velocities during both peak systolic and mid‐diastolic phases. This shows that the LV and ECMO device supplied fluid into the aorta with less flow resistance, whereas other modes exhibited higher flow resistance due to the flow collision of antegrade LV and retrograde ECMO flow in the aorta. Conclusion: Pulsatile flow ECMO with better placement of ECMO pulse delivery in the cardiac cycle could develop greater pulsatility into the aorta, which is crucial for transferring haemodynamic energy and reducing cardiac afterload.
- 27 November 2017
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 34 (4) , e2937
Evaluation of hemodynamic performance of total cavopulmonary connection (TCPC) with porous inserts
Infants born with univentricular heart disease undergo Fontan surgery to establish separate systemic and pulmonary circulations. This surgery results in better blood circulation across a single ventricle that supplies oxygenated blood to the body and passively returns venous blood to the lungs through the total cavopulmonary connection (TCPC). Reducing the pressure drop across the TCPC during Fontan circulation helps in reducing the work load of univentricular heart, and various designs have been proposed for this purpose. The goal of this work is to analyze the effect of placing a porous insert at an appropriate position in the pulmonary artery, on the pressure drop across the TCPC. A 3D computational model of a total TCPC connection provided with a porous insert is developed and solved by finite volume method, under assumptions of steady, laminar, and Newtonian flows. The effects of the porous medium properties—porosity and permeability—across the connection, are analyzed. Compared to the no‐porous medium case, TCPC with the porous medium insert exhibits a maximum reduction of 27% in energy loss for the flow range studied. The porous medium used in TCPC connection lowers the energy dissipation by curtailing the flow recirculation zones across the connection. The influences of the diameter of the blood vessel, total cardiac output, and the thickness, permeability, and position of porous media on energy loss are analyzed. The criteria to select the porous medium properties and position for a given Fontan geometry are also determined.
- 27 November 2017
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 34 (4) , e2937
Evaluation of hemodynamic performance of total cavopulmonary connection (TCPC) with porous inserts
Infants born with univentricular heart disease undergo Fontan surgery to establish separate systemic and pulmonary circulations. This surgery results in better blood circulation across a single ventricle that supplies oxygenated blood to the body and passively returns venous blood to the lungs through the total cavopulmonary connection (TCPC). Reducing the pressure drop across the TCPC during Fontan circulation helps in reducing the work load of univentricular heart, and various designs have been proposed for this purpose. The goal of this work is to analyze the effect of placing a porous insert at an appropriate position in the pulmonary artery, on the pressure drop across the TCPC. A 3D computational model of a total TCPC connection provided with a porous insert is developed and solved by finite volume method, under assumptions of steady, laminar, and Newtonian flows. The effects of the porous medium properties—porosity and permeability—across the connection, are analyzed. Compared to the no‐porous medium case, TCPC with the porous medium insert exhibits a maximum reduction of 27% in energy loss for the flow range studied. The porous medium used in TCPC connection lowers the energy dissipation by curtailing the flow recirculation zones across the connection. The influences of the diameter of the blood vessel, total cardiac output, and the thickness, permeability, and position of porous media on energy loss are analyzed. The criteria to select the porous medium properties and position for a given Fontan geometry are also determined.