Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance
Open Access
- 21 April 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (2) , 1626-1635
Abstract
Robotic systems have slowly entered the realm of modern medicine; however, outside the operating room, medical robotics has yet to be translated to more routine interventions such as blood sampling or intravenous fluid delivery. In this paper, we present a medical robot that safely and rapidly cannulates peripheral blood vessels-a procedure commonly known as venipuncture. The device uses near-infrared and ultrasound imaging to scan and select suitable injection sites, and a 9-DOF robot to insert the needle into the center of the vessel based on image and force guidance. We first present the system design and visual-servoing scheme of the latest generation robot, and then evaluate the performance of the device through workspace simulations and free-space positioning tests. Finally, we perform a series of motion tracking experiments using stereo vision, ultrasound, and force sensing to guide the position and orientation of the needle tip. Positioning experiments indicate sub-millimeter accuracy and repeatability over the operating workspace of the system, while tracking studies demonstrate real-time needle servoing in response to moving targets. Finally, robotic phantom cannulations demonstrate the use of multiple system states to confirm that the needle has reached the center of the vessel.Keywords
Funding Information
- National Science Foundation (1448550)
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health (R01EB020036)
- NSF Graduate Research Fellowship (DGE-0937373)
- NIH/National Institute of General Medical Science Rutgers Biotechnology Training Program (T32 GM008339)
- NIH (EB018191)
This publication has 28 references indexed in Scilit:
- Preliminary in vivo evaluation of a needle insertion manipulator for central venous catheterizationROBOMECH Journal, 2014
- Towards a Low-Cost Mobile Subcutaneous Vein Detection Solution Using Near-Infrared SpectroscopyThe Scientific World Journal, 2014
- The VeinViewer Vascular Imaging System Worsens First-Attempt Cannulation Rate for Experienced Nurses in Infants and Children with Anticipated Difficult Intravenous AccessAnesthesia & Analgesia, 2013
- Gain-Scheduling Control of Teleoperation Systems Interacting With Soft TissuesIEEE Transactions on Industrial Electronics, 2012
- Ultrasonographically Guided Peripheral Intravenous Cannulation in Emergency Department Patients With Difficult Intravenous Access: A Randomized TrialAnnals of Emergency Medicine, 2009
- Implementation of Bilateral Control System Based on Acceleration Control Using FPGA for Multi-DOF Haptic Endoscopic Surgery RobotIEEE Transactions on Industrial Electronics, 2008
- Difficult Peripheral Venous Access: Recognizing and Managing the Patient at RiskJournal of the Association for Vascular Access, 2008
- Mechatronic Design of a New Robot for Force Control in Minimally Invasive SurgeryIEEE/ASME Transactions on Mechatronics, 2007
- Object trackingACM Computing Surveys, 2006
- Detection of needle puncture to blood vessel using puncture force measurementMedical & Biological Engineering & Computing, 2005