    Deep learning robotic guidance for autonomous vascular access

    by Alvin I. Chen, Max L. Balter, Timothy J. Maguire, Martin L. Yarmush


  • Automated end-to-end blood testing at the point-of-care: Integration of robotic phlebotomy with downstream sample processing

    by M.L. Balter, J.M. Leipheimer, A.I. Chen, A. Shrirao, T.J. Maguire, M.L. Yarmush

    Diagnostic blood testing is the most commonly performed clinical procedure in the world, and influences the majority of medical decisions made in hospital and laboratory settings. However, manual blood draw success rates are dependent on clinician skill and patient physiology, and results are generated almost exclusively in centralized labs from large-volume samples using labor-intensive analytical techniques. This paper presents a medical device that enables end-to-end blood testing by performing blood draws and providing diagnostic results in a fully automated fashion at the point-of-care. The system couples an image-guided venipuncture robot, developed to address the challenges of routine venous access, with a centrifuge-based blood analyzer to obtain quantitative measurements of hematology. We first demonstrate a white blood cell assay on the analyzer, using a blood mimicking fluid spiked with fluorescent microbeads, where the area of the packed bead layer is correlated with the bead concentration. Next we perform experiments to evaluate the pumping efficiency of the sample handling module. Finally, studies are conducted on the integrated device — from blood draw to analysis — using blood vessel phantoms to assess the accuracy and repeatability of the resulting white blood cell assay.


  • Open Access

    Design and Evaluation of a Robotic Device for Automated Tail Vein Cannulations in Rodent Models

    by Alex Fromholtz, Max L. Balter, Alvin I. Chen, Josh M. Leipheimer, Anil Shrirao, Timothy J. Maguire, Martin L. Yarmush

    Preclinical testing in rodent models is a ubiquitous part of modern biomedical research and commonly involves accessing the venous bloodstream for blood sampling and drug delivery. Manual tail vein cannulation is a time-consuming process and requires significant skill and training, particularly since improperly inserted needles can affect the experimental results and study outcomes. In this paper, we present a miniaturized, robotic medical device for automated, image-guided tail vein cannulations in rodent models. The device is composed of an actuated three degrees-of-freedom (DOFs) needle manipulator, three-dimensional (3D) near-infrared (NIR) stereo cameras, and an animal holding platform. Evaluating the system through a series of workspace simulations and free-space positioning tests, the device exhibited a sufficient work volume for the needle insertion task and submillimeter accuracy over the calibration targets. The results indicate that the device is capable of cannulating tail veins in rodent models as small as 0.3 mm in diameter, the smallest diameter vein required to target.


  • Differential leukocyte counting via fluorescent detection and image processing on a centrifugal microfluidic platform

    by Max L. Balter, Alvin I. Chen, C. Amara Colinco, Alexander Gorshkov, Brian Bixon, Vincent Martin, Alexander Fromholtz, Timothy J. Maguire, Martin L. Yarmush

    Centrifugal microfluidics has received much attention in the last decade for the automation of blood testing at the point-of-care, specifically for the detection of chemistries, proteins, and nucleic acids. However, the detection of common blood cells on-disc, particularly leukocytes, remains a challenge. In this paper, we present two methods for enumerating leukocytes on a centrifugal platform using a custom-built fluorescent microscope, nuclear staining, and image processing. In the first method, cell analysis is performed in glass capillary tubes; in the second, acrylic chips are used. A bulk-cell analysis approach is implemented in both cases where the pixel areas of fractionated lymphocyte/monocyte and granulocyte layers are correlated with cell counts. Generating standard curves using porcine blood sample controls, we observed strong linear fits to measured cell counts using both methods. Analyzing the pixel intensities of the fluorescing white cell region, we are able to differentiate lymphocytes from monocytes via pixel clustering, demonstrating the capacity to perform a 3-part differential. Finally, a discussion of pros and cons of the bulk-cell analysis approach concludes the paper.


  • Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties

    by Alvin I. Chen, Max L. Balter, Melanie I. Chen, Daniel Gross, Sheikh K. Alam, Timothy J. Maguire, Martin L. Yarmush

    Purpose: This paper describes the design, fabrication, and characterization of multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties. The phantoms comprise epidermis, dermis, and hypodermis skin layers, blood vessels, and blood mimicking fluid. Each tissue component may be individually tailored to a range of physiological and demographic conditions.Methods: The skin layers were constructed from varying concentrations of gelatin and agar. Synthetic melanin, India ink, absorbing dyes, and Intralipid were added to provide optical absorption and scattering in the skin layers. Bovine serum albumin was used to increase acoustic attenuation, and 40 μm diameter silica microspheres were used to induce acoustic backscatter. Phantom vessels consisting of thin‐walled polydimethylsiloxane tubing were embedded at depths of 2–6 mm beneath the skin, and blood mimicking fluid was passed through the vessels. The phantoms were characterized through uniaxial compression and tension experiments, rheological frequency sweep studies, diffuse reflectance spectroscopy, and ultrasonic pulse‐echo measurements. Results were then compared to in vivo and ex vivo literature data.Results: The elastic and dynamic shear behavior of the phantom skin layers and vessel wall closely approximated the behavior of porcine skin tissues and human vessels. Similarly, the optical properties of the phantom tissue components in the wavelength range of 400–1100 nm, as well as the acoustic properties in the frequency range of 2–9 MHz, were comparable to human tissue data. Normalized root mean square percent errors between the phantom results and the literature reference values ranged from 1.06% to 9.82%, which for many measurements were less than the sample variability. Finally, the mechanical and imaging characteristics of the phantoms were found to remain stable after 30 days of storage at 21 °C.Conclusions: The phantoms described in this work simulate the mechanical, optical, and acoustic properties of human skin tissues, vessel tissue, and blood. In this way, the phantoms are uniquely suited to serve as test models for multimodal imaging techniques and image‐guided interventions.


  • Open Access

    Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance

    by Max L. Balter, Alvin I. Chen, Timothy J. Maguire, Martin L. Yarmush

    Robotic systems have slowly entered the realm of modern medicine; however, outside the operating room, medical robotics has yet to be translated to more routine interventions such as blood sampling or intravenous fluid delivery. In this paper, we present a medical robot that safely and rapidly cannulates peripheral blood vessels-a procedure commonly known as venipuncture. The device uses near-infrared and ultrasound imaging to scan and select suitable injection sites, and a 9-DOF robot to insert the needle into the center of the vessel based on image and force guidance. We first present the system design and visual-servoing scheme of the latest generation robot, and then evaluate the performance of the device through workspace simulations and free-space positioning tests. Finally, we perform a series of motion tracking experiments using stereo vision, ultrasound, and force sensing to guide the position and orientation of the needle tip. Positioning experiments indicate sub-millimeter accuracy and repeatability over the operating workspace of the system, while tracking studies demonstrate real-time needle servoing in response to moving targets. Finally, robotic phantom cannulations demonstrate the use of multiple system states to confirm that the needle has reached the center of the vessel.


  • Developing the World?s First Portable Medical Robot for Autonomous Venipuncture [Industrial Activities]

    by Alvin I. Chen, Max L. Balter, Timothy J. Maguire

    In the past decade, robotic technology has slowly made its push into the medical field. Advanced surgical robots, in particular, have become technological icons in today's hospitals. However, the use of robotics for everyday medicine remains a major challenge due to the cost and size of current systems - the da Vinci Surgical System, for example, can cost several million dollars and requires a dedicated operating room. Discusses the work done by VascuLogic to commercialize imaging and robotic technologies designed specifically for compact, portable, and low-cost medical devices.


  • Real-time needle steering in response to rolling vein deformation by a 9-DOF image-guided autonomous venipuncture robot

    by Alvin I. Chen, Max L. Balter, Timothy J. Maguire, Martin L. Yarmush

    Venipuncture is the most common invasive medical procedure performed in the United States and the number one cause of hospital injury. Failure rates are particularly high in pediatric and elderly patients, whose veins tend to deform, move, or roll as the needle is introduced. To improve venipuncture accuracy in challenging patient populations, we have developed a portable device that autonomously servos a needle into a suitable vein under image guidance. The device operates in real time, combining near-infrared and ultrasound imaging, computer vision software, and a 9 degrees-of-freedom robot that servos the needle. In this paper, we present the kinematic and mechanical design of the latest generation robot. We then investigate in silico and in vitro the mechanics of vessel rolling and deformation in response to needle insertions performed by the robot. Finally, we demonstrate how the robot can make real-time adjustments under ultrasound image guidance to compensate for subtle vessel motions during venipuncture.


  • The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot

    by Max L. Balter, Alvin I. Chen, Timothy J. Maguire, Martin L. Yarmush

    Accessing the venous bloodstream to deliver fluids or obtain a blood sample is the most common clinical routine practiced in the U.S. Practitioners continue to rely on manual venipuncture techniques, but success rates are heavily dependent on clinician skill and patient physiology. In the U.S., failure rates can be as high as 50% in difficult patients, making venipuncture the leading cause of medical injury. To improve the rate of first-stick success, we have developed a portable autonomous venipuncture device that robotically servos a needle into a suitable vein under image guidance. The device operates in real time, combining near-infrared and ultrasound imaging, image analysis, and a 7-degree-of-freedom (DOF) robotic system to perform the venipuncture. The robot consists of a 3-DOF gantry to image the patient's peripheral forearm veins and a miniaturized 4-DOF serial arm to guide the cannula into the selected vein under closed-loop control. In this paper, we present the system architecture of the robot and evaluate the accuracy and precision through tracking, free-space positioning, and in vitro phantom cannulation experiments. The results demonstrate submillimeter accuracy throughout the operating workspace of the manipulator and a high rate of success when cannulating phantom veins in a skin-mimicking tissue model.


  • Design, Construction, and Testing of a Flying Prey Simulator

    by Adam R. Zinman, Max L. Balter, Robert Olberg, Ashok Ramasubramanian, David A. Hodgson

    The goal of this research project is to investigate the neuronal control of flying prey interception in dragonflies by designing, constructing, and testing an apparatus to simulate the complex motions of a flying insect. Our three-dimensional motion device is capable of mimicking a flying insect by moving a small bead accurately up to speeds of 1 m/s in any direction. Dragonflies are efficient aerial predators that can intercept and capture small insects in flight. Our stimulus device will be used to determine the way in which dragonfly neurons encode information about object movement in three dimensions. Sinusoidal position tracking experiments using multiple input frequencies were conducted using the apparatus. The results indicate that the machine operates with good repeatability with little variability between trials. Preliminary dragonfly testing with the apparatus showed favorable results, indicating proof of concept.