Improvements on Bismuth Tri-iodide Platelets For Room Temperature X-ray Detection
- 1 October 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6 (10823654) , 3616-3621
Abstract
Bismuth tri-iodide synthesized from bismuth carbonate and potassium iodide and then treated with hydriodic acid was used as starting material. Platelets were grown by physical vapor deposition (PVD), with a source temperature of 320 degC, during 1 day. Growth temperature was about 250 degC. Platelets are up to 30 times 20 mm 2 in size, and from 50 to 80 mum in thickness. Platelet surface exhibits extreme brightness and higher uniformity than the ones previously reported, confirmed by optical and scanning electron microscopy. Several reactants were used for platelets' surface etching; any of them did not improve the crystal surface. Detectors were made with the as-grown platelets by Pd thermal deposition (contact areas of 0.071 cm 2 ), with and without guard-ring, Pd wire attachment with aquadag and acrylic encapsulation. Detector X-ray response was measured by irradiation with a 241 Am source of 3.5 mR/h. Resistivities up to 1.7 times 10 13 Omega-cm were obtained, the best reported for detectors made with monocrystals of this material, which correlates with the fact that these detectors show the best signal to dark relation as response to an X-ray moderate radiation exposure: 11.0, with a bias of 60 V. This new generation of platelets give better surfaces, higher resistivities, lower dark currents and better signal to dark relation than previous ones.Keywords
This publication has 28 references indexed in Scilit:
- Growth of bismuth tri-iodide platelets for room temperature X-ray detectionIEEE Transactions on Nuclear Science, 2004
- Correlation between growth orientation and growth temperature for bismuth tri‐iodide filmsCrystal Research and Technology, 2004
- Bismuth Tri-Iodide Polycrystalline Films for Digital X-Ray Radiography ApplicationsIEEE Transactions on Nuclear Science, 2004
- Growth of mercuric iodide platelets for X-ray room temperature detectors in the HgI2–HI–H2O systemJournal of Crystal Growth, 2000
- Optimization of mercuric iodide platelets growth by the polymer controlled vapor transport methodMaterials Research, 1999
- Lead iodide X-ray detection systemsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Comparison of HgI2, CdTe and Si (p-i-n) X-ray detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Recent progress in lead iodide X-ray spectrometer developmentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992
- An improvement in growing large, oriented lead iodide single crystals for detector applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992
- Vapour growth of bulk anisotropic crystals: case study of α-HgI2Journal of Crystal Growth, 1991