Timing, Energy, and Spatial Characterization of Highly Sampled Monolithic PET Detectors With Different Thicknesses
- 29 May 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 704-711
Abstract
The HyPET project proposes a hybrid dedicated time of flight-positron emission tomography for prostate imaging, with pixelated detector blocks in the front layer and monolithic blocks in the back layer. In this work, four detector configurations have been experimentally evaluated for the rear detector layer. The detector configuration consists of LYSO monolithic blocks with the same size (25.4 mm $\times25.4$ mm) but different thicknesses (5, 7.5, 10, and 15 mm) coupled to the same silicon photomultiplier array. Each detector configuration has been experimentally characterized in terms of time, energy, and spatial resolution by scanning the crystal surface using a fan beam in steps of 0.25 mm. Regarding spatial resolution, the interaction position was estimated using a neural network technique. All resolutions except energy, which remains nearly constant at 17% for all cases, show better values for the 5-mm detector thickness. We have achieved spatial resolution values of full width at half of the maximum of 1.02 ± 0.10, 1.19 ± 0.13, 1.53 ± 0.17, and 2.33 ± 0.55 mm, for 5, 7.5, 10, and 15 mm blocks, respectively. The detector time resolution obtained was 275 ± 26, 291 ± 21, 344 ± 48, and 433 ± 45 ps, respectively, using the energy-weighted average method for the time stamps.Keywords
Funding Information
- NIH NIBIB (R21EB028420)
This publication has 23 references indexed in Scilit:
- Experimental results with TOFPET2 ASIC for time-of-flight applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- A Novel DOI Positioning Algorithm for Monolithic Scintillator Crystals in PET Based on Gradient Tree BoostingIEEE Transactions on Radiation and Plasma Medical Sciences, 2018
- Sub-3 mm, near-200 ps TOF/DOI-PET imaging with monolithic scintillator detectors in a 70 cm diameter tomographic setupPhysics in Medicine & Biology, 2018
- Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector LayersIEEE Transactions on Radiation and Plasma Medical Sciences, 2017
- A Novel Method for $\gamma - \text{photons}$ Depth-of-Interaction Detection in Monolithic Scintillation CrystalsIEEE Transactions on Nuclear Science, 2016
- Parallax error in long-axial field-of-view PET scanners—a simulation studyPhysics in Medicine & Biology, 2016
- Position algorithm for monolithic scintillation crystals based on charge projection readoutJournal of Instrumentation, 2016
- Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capabilityBiomedical Engineering Letters, 2011
- From PET detectors to PET scannersEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Properties of the center of gravity as an algorithm for position measurementsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002