John Barrio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
John Barrio has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Gabriela Llosa
Instituto de Física Corpuscular (IFIC), CSIC-UV, Valencia, Spain
37 shared publications - Carlos Lacasta
Centro Mixto Universidad de Valencia - CSIC
34 shared publications - Carles Solaz
Instituto de Fisica Corpuscular
26 shared publications - Magdalena Rafecas
Universität zu Lübeck
18 shared publications - Ane Etxebeste
CREATIS, 21 avenue Jean Capelle, Villeurbanne, 69621, France
15 shared publications - Josep Francisco Oliver
Instituto de Fisica Corpuscular, Universidad de Valencia, Edificio Institutos de Paterna, Apartado de Correos 22085, E-46071 Valencia, Valencia, SPAIN
14 shared publications
Latest Publications
- Open Access
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (7) , 866-871
Single-Ended Readout PET Detector Based on Pixelated Crystals With TOF and DOI Capabilities
Traditional PET detectors based on pixelated scintillation crystals with single-ended readout do not provide depth of interaction (DOI) information in an easy and costeffective way. In this work, we propose a PET detector with singleended readout and 1:1 coupling, based on arrays of naked pixelated crystals that are glued in one direction, and optically separated in the other one. We have named this approach as pseudo-slab. In this configuration, some of the optical photons will propagate in the glued direction, generating a light distribution from which DOI information can be retrieved. We have characterized four different detector configurations, all of them consisting of a linear array of 1 8 LYSO crystals of 3 3 20 mm3 each, with an optical glue of approximately 70 μJm in between them. The top and bottom faces are polished, and with a different number of unpolished lateral surfaces (2 versus 4) and different wrappings (Enhanced Specular Reflector versus BaSO4). The results obtained for the four detector configurations show energy resolutions ranging from 8.5% to 9.8% and coincidence time resolutions (with a reference pixel) below 290 ps for all cases using only the fastest timestamp and close to 230 ps when energy-weighted averaging of multiple timestamps is applied (corresponding to 182 ps detector time resolution). Regarding DOI performance, all configurations provide DOI information, showing a better performance with more number of unpolished faces and also when using BaSO4 as a reflector.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (7) , 866-871
Open AccessSingle-Ended Readout PET Detector Based on Pixelated Crystals With TOF and DOI Capabilities
Traditional PET detectors based on pixelated scintillation crystals with single-ended readout do not provide depth of interaction (DOI) information in an easy and costeffective way. In this work, we propose a PET detector with singleended readout and 1:1 coupling, based on arrays of naked pixelated crystals that are glued in one direction, and optically separated in the other one. We have named this approach as pseudo-slab. In this configuration, some of the optical photons will propagate in the glued direction, generating a light distribution from which DOI information can be retrieved. We have characterized four different detector configurations, all of them consisting of a linear array of 1 8 LYSO crystals of 3 3 20 mm3 each, with an optical glue of approximately 70 μJm in between them. The top and bottom faces are polished, and with a different number of unpolished lateral surfaces (2 versus 4) and different wrappings (Enhanced Specular Reflector versus BaSO4). The results obtained for the four detector configurations show energy resolutions ranging from 8.5% to 9.8% and coincidence time resolutions (with a reference pixel) below 290 ps for all cases using only the fastest timestamp and close to 230 ps when energy-weighted averaging of multiple timestamps is applied (corresponding to 182 ps detector time resolution). Regarding DOI performance, all configurations provide DOI information, showing a better performance with more number of unpolished faces and also when using BaSO4 as a reflector.
- Open Access
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (8) , 876-885
Detector Characterization of a High-Resolution Ring for PET Imaging of Mice Heads With Sub-200-ps TOF
Positron Emission Tomography (PET) stands out as a highly specific molecular imaging technique. However, its detection sensitivity remains a challenge. The implementation of Time-of-Flight (TOF) PET technology enhances sensitivity by precisely measuring the time lapse between the annihilation photons. Moreover, by characterizing scattered (Compton) events, the effective sensitivity of PET imaging might significantly be enhanced. In this work, we present the scatter sub-system of a 2 layers preclinical TOF-PET scanner for mice head imaging. The scatter sub-system is composed of 8 identical modules based on analog SiPMs coupled to crystal arrays of 24 × 24 LYSO pixels with 0.95 mm × 0.95 mm × 3 mm dimensions. The system has 29 mm bore and 50.8 mm axial length. An average CTR of 192± 1 ps was obtained for the whole sub-system at the photopeak energy range after energy and timing corrections, and CTR values as good as 155 ps were found for some individual pixels. The transit time spread at the SiPM level was also studied and corrected, achieving a mean value of 41 ps of maximum time difference at the sensor corners with respect to the center. Voronoi diagrams were implemented to correct for position decoding.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (8) , 876-885
Open AccessDetector Characterization of a High-Resolution Ring for PET Imaging of Mice Heads With Sub-200-ps TOF
Positron Emission Tomography (PET) stands out as a highly specific molecular imaging technique. However, its detection sensitivity remains a challenge. The implementation of Time-of-Flight (TOF) PET technology enhances sensitivity by precisely measuring the time lapse between the annihilation photons. Moreover, by characterizing scattered (Compton) events, the effective sensitivity of PET imaging might significantly be enhanced. In this work, we present the scatter sub-system of a 2 layers preclinical TOF-PET scanner for mice head imaging. The scatter sub-system is composed of 8 identical modules based on analog SiPMs coupled to crystal arrays of 24 × 24 LYSO pixels with 0.95 mm × 0.95 mm × 3 mm dimensions. The system has 29 mm bore and 50.8 mm axial length. An average CTR of 192± 1 ps was obtained for the whole sub-system at the photopeak energy range after energy and timing corrections, and CTR values as good as 155 ps were found for some individual pixels. The transit time spread at the SiPM level was also studied and corrected, achieving a mean value of 41 ps of maximum time difference at the sensor corners with respect to the center. Voronoi diagrams were implemented to correct for position decoding.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (8) , 785-793
Time and Energy Characterization of Semi-Monolithic Detectors With Different Treatments and SiPMs Suitable for Clinical Imaging
The use of detectors based on semi-monolithic crystals can be of interest to clinical PET scanners due to their time of flight (TOF) and depth of interaction (DOI) capabilities. In this work, timing and energy characterization of four different detector configurations based on arrays of 8 LYSO slabs of 25.4×3.1×20 mm each coupled to SiPMs have been carried out. On the one hand, two different surface treatments have been studied. In one configuration, all the slab surfaces were treated with ESR (named ESR). In the other configuration, a retroreflector layer was added to the entrance face and the pixelated external faces were painted black (named ESR+B+RR). On the other hand, two different SiPM array models belonging to the series S13 and S14 from Hamamatsu Photonics were also compared. In all cases, the readout was performed by the TOFPET2 ASIC. The results show an energy resolution and a detector time resolution (DTR) as good as 12.5% and 193 ps, respectively, for the ESR treatment and the S13 photosensor. For the ESR+B+RR treatment and S13, the energy resolution and DTR are 14.6% and 238 ps, respectively. When using the S14, the energy resolutions and DTRs are, respectively, 11.6% and 219 ps for the ESR treatment, and 14.2% and 339 ps for the ESR+B+RR treatment.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (8) , 785-793
Time and Energy Characterization of Semi-Monolithic Detectors With Different Treatments and SiPMs Suitable for Clinical Imaging
The use of detectors based on semi-monolithic crystals can be of interest to clinical PET scanners due to their time of flight (TOF) and depth of interaction (DOI) capabilities. In this work, timing and energy characterization of four different detector configurations based on arrays of 8 LYSO slabs of 25.4×3.1×20 mm each coupled to SiPMs have been carried out. On the one hand, two different surface treatments have been studied. In one configuration, all the slab surfaces were treated with ESR (named ESR). In the other configuration, a retroreflector layer was added to the entrance face and the pixelated external faces were painted black (named ESR+B+RR). On the other hand, two different SiPM array models belonging to the series S13 and S14 from Hamamatsu Photonics were also compared. In all cases, the readout was performed by the TOFPET2 ASIC. The results show an energy resolution and a detector time resolution (DTR) as good as 12.5% and 193 ps, respectively, for the ESR treatment and the S13 photosensor. For the ESR+B+RR treatment and S13, the energy resolution and DTR are 14.6% and 238 ps, respectively. When using the S14, the energy resolutions and DTRs are, respectively, 11.6% and 219 ps for the ESR treatment, and 14.2% and 339 ps for the ESR+B+RR treatment.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 704-711
Timing, Energy, and Spatial Characterization of Highly Sampled Monolithic PET Detectors With Different Thicknesses
The HyPET project proposes a hybrid dedicated time of flight-positron emission tomography for prostate imaging, with pixelated detector blocks in the front layer and monolithic blocks in the back layer. In this work, four detector configurations have been experimentally evaluated for the rear detector layer. The detector configuration consists of LYSO monolithic blocks with the same size (25.4 mm $\times25.4$ mm) but different thicknesses (5, 7.5, 10, and 15 mm) coupled to the same silicon photomultiplier array. Each detector configuration has been experimentally characterized in terms of time, energy, and spatial resolution by scanning the crystal surface using a fan beam in steps of 0.25 mm. Regarding spatial resolution, the interaction position was estimated using a neural network technique. All resolutions except energy, which remains nearly constant at 17% for all cases, show better values for the 5-mm detector thickness. We have achieved spatial resolution values of full width at half of the maximum of 1.02 ± 0.10, 1.19 ± 0.13, 1.53 ± 0.17, and 2.33 ± 0.55 mm, for 5, 7.5, 10, and 15 mm blocks, respectively. The detector time resolution obtained was 275 ± 26, 291 ± 21, 344 ± 48, and 433 ± 45 ps, respectively, using the energy-weighted average method for the time stamps.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (7) , 704-711
Timing, Energy, and Spatial Characterization of Highly Sampled Monolithic PET Detectors With Different Thicknesses
The HyPET project proposes a hybrid dedicated time of flight-positron emission tomography for prostate imaging, with pixelated detector blocks in the front layer and monolithic blocks in the back layer. In this work, four detector configurations have been experimentally evaluated for the rear detector layer. The detector configuration consists of LYSO monolithic blocks with the same size (25.4 mm $\times25.4$ mm) but different thicknesses (5, 7.5, 10, and 15 mm) coupled to the same silicon photomultiplier array. Each detector configuration has been experimentally characterized in terms of time, energy, and spatial resolution by scanning the crystal surface using a fan beam in steps of 0.25 mm. Regarding spatial resolution, the interaction position was estimated using a neural network technique. All resolutions except energy, which remains nearly constant at 17% for all cases, show better values for the 5-mm detector thickness. We have achieved spatial resolution values of full width at half of the maximum of 1.02 ± 0.10, 1.19 ± 0.13, 1.53 ± 0.17, and 2.33 ± 0.55 mm, for 5, 7.5, 10, and 15 mm blocks, respectively. The detector time resolution obtained was 275 ± 26, 291 ± 21, 344 ± 48, and 433 ± 45 ps, respectively, using the energy-weighted average method for the time stamps.
- 9 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 245011
Position estimation using neural networks in semi-monolithic PET detectors
Objective . The goal of this work is to experimentally compare the 3D spatial and energy resolution of a semi-monolithic detector suitable for total-body positron emission tomography (TB-PET) scanners using different surface crystal treatments and silicon photomultiplier (SiPM) models. Approach . An array of 1 × 8 lutetium yttrium oxyorthosilicate (LYSO) slabs of 25.8 × 3.1 × 20 mm 3 separated with Enhanced Specular Reflector (ESR) was coupled to an array of 8 × 8 SiPMs. Three different treatments for the crystal were evaluated: ESR + RR + B , with lateral faces black (B) painted and a retroreflector (RR) layer added to the top face; ESR + RR , with lateral faces covered with ESR and a RR layer on the top face and; All ESR, with lateral and top sides with ESR. Additionally, two SiPM array models from Hamamatsu Photonics belonging to the series S13361-3050AE-08 (S13) and S14161-3050AS-08 (S14) have been compared. Coincidence data was experimentally acquired using a 22 Na point source, a pinhole collimator, a reference detector and moving the detector under study in 1 mm steps in the x - and DOI - directions. The spatial performance was evaluated by implementing a neural network (NN) technique for the impact position estimation in the x - (monolithic) and DOI directions. Results . Energy resolution values of 16 ± 1%, 11 ± 1%, 16 ± 1%, 15 ± 1%, and 13 ± 1% were obtained for the S1 3- ESR + B + RR, S1 3-All ESR, S14- ESR + B + RR, S14- ESR + RR , and S14- All ESR, respectively. Regarding positioning accuracy, mean average error of 1.1 ± 0.5, 1.3 ± 0.5 and 1.3 ± 0.5 were estimated for the x - direction and 1.7 ± 0.8, 2.0 ± 0.9 and 2.2 ± 1.0 for the DOI - direction, for the ESR + B + RR, ESR + RR and All ESR cases, respectively, regardless of the SiPM model. Significance . Overall, the obtained results show that the proposed semi-monolithic detectors are good candidates for building TB-PET scanners.
- 9 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (24) , 245011
Position estimation using neural networks in semi-monolithic PET detectors
Objective . The goal of this work is to experimentally compare the 3D spatial and energy resolution of a semi-monolithic detector suitable for total-body positron emission tomography (TB-PET) scanners using different surface crystal treatments and silicon photomultiplier (SiPM) models. Approach . An array of 1 × 8 lutetium yttrium oxyorthosilicate (LYSO) slabs of 25.8 × 3.1 × 20 mm 3 separated with Enhanced Specular Reflector (ESR) was coupled to an array of 8 × 8 SiPMs. Three different treatments for the crystal were evaluated: ESR + RR + B , with lateral faces black (B) painted and a retroreflector (RR) layer added to the top face; ESR + RR , with lateral faces covered with ESR and a RR layer on the top face and; All ESR, with lateral and top sides with ESR. Additionally, two SiPM array models from Hamamatsu Photonics belonging to the series S13361-3050AE-08 (S13) and S14161-3050AS-08 (S14) have been compared. Coincidence data was experimentally acquired using a 22 Na point source, a pinhole collimator, a reference detector and moving the detector under study in 1 mm steps in the x - and DOI - directions. The spatial performance was evaluated by implementing a neural network (NN) technique for the impact position estimation in the x - (monolithic) and DOI directions. Results . Energy resolution values of 16 ± 1%, 11 ± 1%, 16 ± 1%, 15 ± 1%, and 13 ± 1% were obtained for the S1 3- ESR + B + RR, S1 3-All ESR, S14- ESR + B + RR, S14- ESR + RR , and S14- All ESR, respectively. Regarding positioning accuracy, mean average error of 1.1 ± 0.5, 1.3 ± 0.5 and 1.3 ± 0.5 were estimated for the x - direction and 1.7 ± 0.8, 2.0 ± 0.9 and 2.2 ± 1.0 for the DOI - direction, for the ESR + B + RR, ESR + RR and All ESR cases, respectively, regardless of the SiPM model. Significance . Overall, the obtained results show that the proposed semi-monolithic detectors are good candidates for building TB-PET scanners.
- Open Access
- 1 December 2022
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 18 (1) , 107-119
A new brain dedicated PET scanner with 4D detector information
In this article, we present the geometrical design and preliminary results of a high sensitivity organ-specific Positron Emission Tomography (PET) system dedicated to the study of the human brain. The system, called 4D-PET, will allow accurate imaging of brain studies due to its expected high sensitivity, high 3D spatial resolution and, by including precise photon time of flight (TOF) information, a boosted signal-to-noise ratio (SNR). The 4D-PET system incorporates an innovative detector design based on crystal slabs (semi-monolithic) that enables accurate 3D photon impact positioning (including photon Depth of Interaction (DOI) measurement), while providing a precise determination of the photon arrival time to the detector. The detector includes a novel readout system that reduces the number of detector signals in a ratio of 4:1 thus, alleviating complexity and cost. The analog output signals are fed to the TOFPET2 ASIC (PETsys) for scalability purposes. The present manuscript reports the evaluation of the 4D-PET detector, achieving best values 3D resolution values of <1.6 mm (pixelated axis), 2.7±0.5 mm (monolithic axis) and 3.4±1.1 (DOI axis) mm; 359 ± 7 ps coincidence time resolution (CTR); 10.2±1.5 % energy resolution; and sensitivity of 16.2% at the center of the scanner (simulated). Moreover, a comprehensive description of the 4D-PET architecture (that includes 320 detectors), some pictures of its mechanical assembly, and simulations on the expected image quality are provided.
- 1 December 2022
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 18 (1) , 107-119
Open AccessA new brain dedicated PET scanner with 4D detector information
In this article, we present the geometrical design and preliminary results of a high sensitivity organ-specific Positron Emission Tomography (PET) system dedicated to the study of the human brain. The system, called 4D-PET, will allow accurate imaging of brain studies due to its expected high sensitivity, high 3D spatial resolution and, by including precise photon time of flight (TOF) information, a boosted signal-to-noise ratio (SNR). The 4D-PET system incorporates an innovative detector design based on crystal slabs (semi-monolithic) that enables accurate 3D photon impact positioning (including photon Depth of Interaction (DOI) measurement), while providing a precise determination of the photon arrival time to the detector. The detector includes a novel readout system that reduces the number of detector signals in a ratio of 4:1 thus, alleviating complexity and cost. The analog output signals are fed to the TOFPET2 ASIC (PETsys) for scalability purposes. The present manuscript reports the evaluation of the 4D-PET detector, achieving best values 3D resolution values of <1.6 mm (pixelated axis), 2.7±0.5 mm (monolithic axis) and 3.4±1.1 (DOI axis) mm; 359 ± 7 ps coincidence time resolution (CTR); 10.2±1.5 % energy resolution; and sensitivity of 16.2% at the center of the scanner (simulated). Moreover, a comprehensive description of the 4D-PET architecture (that includes 320 detectors), some pictures of its mechanical assembly, and simulations on the expected image quality are provided.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (5) , 510-516
Metascintillators: New Results for TOF-PET Applications
We report on the progress on a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing a bunch of prompt photons from the energy leakage of the recoil photoelectric electron. From a Geant4 simulation of the energy sharing distribution between the dense and the fast scintillator on 42 LYSO-based and 42 BGO-based configurations, a detailed study of the timing performance has been performed on a selection of the most promising 12 LYSO-based and 14 BGO-based metascintillators. A Monte Carlo simulation was first performed to extrapolate from direct measurements of the performance of the metascintillator components, the detector time resolution (DTR), and sensitivity on the basis of the simulated amount of energy leakage to the fast scintillator. An analytic algorithm was then applied to determine an equivalent coincidence time resolution (CTR) from the random association of the DTR distributions from two metapixels in coincidence. This equivalent CTR is calculated in order to obtain the same variance in the reconstructed image as the combination of the DTR distributions of 2 metapixels. Preliminary results confirm that with these simple and still nonoptimized configurations, an equivalent CTR of 150 ps for BGO-based and 140 ps for LYSO-based metapixels of realistic size can be obtained.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (5) , 510-516
Metascintillators: New Results for TOF-PET Applications
We report on the progress on a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing a bunch of prompt photons from the energy leakage of the recoil photoelectric electron. From a Geant4 simulation of the energy sharing distribution between the dense and the fast scintillator on 42 LYSO-based and 42 BGO-based configurations, a detailed study of the timing performance has been performed on a selection of the most promising 12 LYSO-based and 14 BGO-based metascintillators. A Monte Carlo simulation was first performed to extrapolate from direct measurements of the performance of the metascintillator components, the detector time resolution (DTR), and sensitivity on the basis of the simulated amount of energy leakage to the fast scintillator. An analytic algorithm was then applied to determine an equivalent coincidence time resolution (CTR) from the random association of the DTR distributions from two metapixels in coincidence. This equivalent CTR is calculated in order to obtain the same variance in the reconstructed image as the combination of the DTR distributions of 2 metapixels. Preliminary results confirm that with these simple and still nonoptimized configurations, an equivalent CTR of 150 ps for BGO-based and 140 ps for LYSO-based metapixels of realistic size can be obtained.
- Open Access
- 1 November 2021
- Published by Wiley in Medical Physics
- Vol. 48 (12) , 8010-8023
Timing evaluation of a PET detector block based on semi‐monolithic LYSO crystals
Purpose: Detectors for positron emission tomography (PET) typically use two types of scintillation crystals, pixelated or monolithic. A variant of these types of scintillators are the so‐called semi‐monolithic crystals. They consist of a monolithic crystal segmented in one direction in pieces called slabs. These scintillators have the potential to successfully combine the benefits of pixelated and monolithic configurations, providing good timing and spatial resolutions as well as the capacity to decode the depth of interaction (DOI) information. In this work, the timing performance of a detector based on semi‐monolithic crystals was studied in depth. The energy response was also evaluated.Methods: The semi‐monolithic detector consists of 1 × 24 LYSO slabs of 25.4 × 12 × 0.95 mm3 each. The bottom surface of the slabs is coupled to an array of 8 × 8 silicon photomultipliers (SiPMs) of 3 × 3 mm2 active area, 50 μm cell size and 3.2 mm pitch. The 64 output signals were independently readout by the TOFPET2 ASIC. In order to achieve the best coincidence time resolution (CTR), four different time walk corrections were tested. Additional work investigated the best method of combining the timestamps belonging to the same event.Results: The resolvability of the slabs in the measured flood maps improves with the thickness of a light guide placed in between the scintillators and photosensors. The energy resolution does not change significantly with values as good as 13.7%. Regarding the CTR, values of 335.8, 363, 369.8, and 402.5 ps have been obtained for the whole detector for no light guide, 0.5, 1.0, and 1.5 mm thickness light guide cases, respectively. These values further improve to 276.1, 302.6, 305.6 and 336.2 ps, respectively, when energy‐weighted averaging of timestamps is applied.Conclusions: We have shown both an excellent timing resolution and good energy resolution for a PET detector based on semi‐monolithic crystals. The use of light guides of different thicknesses does not significantly affect the energy resolution of the whole detector, but the timing capabilities slightly worsen with the increasing thickness of the light guide.
- 1 November 2021
- Published by Wiley in Medical Physics
- Vol. 48 (12) , 8010-8023
Open AccessTiming evaluation of a PET detector block based on semi‐monolithic LYSO crystals
Purpose: Detectors for positron emission tomography (PET) typically use two types of scintillation crystals, pixelated or monolithic. A variant of these types of scintillators are the so‐called semi‐monolithic crystals. They consist of a monolithic crystal segmented in one direction in pieces called slabs. These scintillators have the potential to successfully combine the benefits of pixelated and monolithic configurations, providing good timing and spatial resolutions as well as the capacity to decode the depth of interaction (DOI) information. In this work, the timing performance of a detector based on semi‐monolithic crystals was studied in depth. The energy response was also evaluated.Methods: The semi‐monolithic detector consists of 1 × 24 LYSO slabs of 25.4 × 12 × 0.95 mm3 each. The bottom surface of the slabs is coupled to an array of 8 × 8 silicon photomultipliers (SiPMs) of 3 × 3 mm2 active area, 50 μm cell size and 3.2 mm pitch. The 64 output signals were independently readout by the TOFPET2 ASIC. In order to achieve the best coincidence time resolution (CTR), four different time walk corrections were tested. Additional work investigated the best method of combining the timestamps belonging to the same event.Results: The resolvability of the slabs in the measured flood maps improves with the thickness of a light guide placed in between the scintillators and photosensors. The energy resolution does not change significantly with values as good as 13.7%. Regarding the CTR, values of 335.8, 363, 369.8, and 402.5 ps have been obtained for the whole detector for no light guide, 0.5, 1.0, and 1.5 mm thickness light guide cases, respectively. These values further improve to 276.1, 302.6, 305.6 and 336.2 ps, respectively, when energy‐weighted averaging of timestamps is applied.Conclusions: We have shown both an excellent timing resolution and good energy resolution for a PET detector based on semi‐monolithic crystals. The use of light guides of different thicknesses does not significantly affect the energy resolution of the whole detector, but the timing capabilities slightly worsen with the increasing thickness of the light guide.
- 8 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (14) , 145005
Image reconstruction for a multi-layer Compton telescope: an analytical model for three interaction events
Compton Cameras are electronically collimated photon imagers suitable for sub-MeV to few MeV gamma-ray detection. Such features are desirable to enable in vivo range verification in hadron therapy, through the detection of secondary Prompt Gammas. A major concern with this technique is the poor image quality obtained when the incoming gamma-ray energy is unknown. Compton Cameras with more than two detector planes (multi-layer Compton Cameras) have been proposed as a solution, given that these devices incorporate more signal sequences of interactions to the conventional two interaction events. In particular, three interaction events convey more spectral information as they allow inferring directly the incident gamma-ray energy. A three-layer Compton Telescope based on continuous Lanthanum (III) Bromide crystals coupled to Silicon Photomultipliers is being developed at the IRIS group of IFIC-Valencia. In a previous work we proposed a spectral reconstruction algorithm for two interaction events based on an analytical model for the formation of the signal. To fully exploit the capabilities of our prototype, we present here an extension of the model for three interaction events. Analytical expressions of the sensitivity and the System Matrix are derived and validated against Monte Carlo simulations. Implemented in a List Mode Maximum Likelihood Expectation Maximization algorithm, the proposed model allows us to obtain four-dimensional (energy and position) images by using exclusively three interaction events. We are able to recover the correct spectrum and spatial distribution of gamma-ray sources when ideal data are employed. However, the uncertainties associated to experimental measurements result in a degradation when real data from complex structures are employed. Incorrect estimation of the incident gamma-ray interaction positions, and missing deposited energy associated with escaping secondaries, have been identified as the causes of such degradation by means of a detailed Monte Carlo study. As expected, our current experimental resolution and efficiency to three interaction events prevents us from correctly recovering complex structures of radioactive sources. However, given the better spectral information conveyed by three interaction events, we expect an improvement of the image quality of conventional Compton imaging when including such events. In this regard, future development includes the incorporation of the model assessed in this work to the two interaction events model in order to allow using simultaneously two and three interaction events in the image reconstruction.
- 8 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (14) , 145005
Image reconstruction for a multi-layer Compton telescope: an analytical model for three interaction events
Compton Cameras are electronically collimated photon imagers suitable for sub-MeV to few MeV gamma-ray detection. Such features are desirable to enable in vivo range verification in hadron therapy, through the detection of secondary Prompt Gammas. A major concern with this technique is the poor image quality obtained when the incoming gamma-ray energy is unknown. Compton Cameras with more than two detector planes (multi-layer Compton Cameras) have been proposed as a solution, given that these devices incorporate more signal sequences of interactions to the conventional two interaction events. In particular, three interaction events convey more spectral information as they allow inferring directly the incident gamma-ray energy. A three-layer Compton Telescope based on continuous Lanthanum (III) Bromide crystals coupled to Silicon Photomultipliers is being developed at the IRIS group of IFIC-Valencia. In a previous work we proposed a spectral reconstruction algorithm for two interaction events based on an analytical model for the formation of the signal. To fully exploit the capabilities of our prototype, we present here an extension of the model for three interaction events. Analytical expressions of the sensitivity and the System Matrix are derived and validated against Monte Carlo simulations. Implemented in a List Mode Maximum Likelihood Expectation Maximization algorithm, the proposed model allows us to obtain four-dimensional (energy and position) images by using exclusively three interaction events. We are able to recover the correct spectrum and spatial distribution of gamma-ray sources when ideal data are employed. However, the uncertainties associated to experimental measurements result in a degradation when real data from complex structures are employed. Incorrect estimation of the incident gamma-ray interaction positions, and missing deposited energy associated with escaping secondaries, have been identified as the causes of such degradation by means of a detailed Monte Carlo study. As expected, our current experimental resolution and efficiency to three interaction events prevents us from correctly recovering complex structures of radioactive sources. However, given the better spectral information conveyed by three interaction events, we expect an improvement of the image quality of conventional Compton imaging when including such events. In this regard, future development includes the incorporation of the model assessed in this work to the two interaction events model in order to allow using simultaneously two and three interaction events in the image reconstruction.
- Open Access
- 3 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (5) , 546-554
Characterization of a High-Aspect Ratio Detector With Lateral Sides Readout for Compton PET
Although Positron Emission Tomography is probably the most specific molecular imaging modality, it still lacks of a high detection sensitivity. One way of improving this is by implementing larger axial scanners and, therefore, increasing the solid angle coverage. Alternatively, it is possible to increase the sensitivity gain by improving the timing capabilities of the detectors. However, from the most fundamental nature of particle interactions with matter, the 511 keV gamma-rays suffer, in most of the cases, from scatter collisions either in the patient or within the detector block, before a photoelectric event eventually occurs. Recovering all scattered (Compton) events would improve scanner sensitivity. In this work we show the performance of a detector block geometry suitable for the development of PET scanners based on several detector layers. A geometry using multiple layers favor the process of scattered events, at the time that allows one for their proper identification. The detector block consists of a LYSO crystal with 51.5×51.5 mm2 surface and 3 mm thickness, resulting in a very high aspect ratio above 17. Four custom-made SiPM arrays of 1×16 elements with 3×3 mm2 area each are coupled to the lateral sides of the crystal. Four different methods to estimate the gamma-ray interaction position using the information collected by the four SiPM arrays have been implemented and compared in order to assess the most suitable one for this detector configuration and aspect ratio. A novel calibration method based on Voronoi diagrams has been successfully implemented, allowing us to recover data for the entire detector block. We have reached an intrinsic spatial resolution for the whole block of less than 1.6 mm FWHM, combined with an energy resolution of 12.1%. We have also compared the performance results with detector blocks using the same crystal but employing the standard backreading approach. Similar results were obtained but making use of 4 times less SiPM active area in the case of the lateral reading compared to the backreading method, and with the possibility to minimize the undesirable scatter in the photosensor layers.
- 3 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 4 (5) , 546-554
Open AccessCharacterization of a High-Aspect Ratio Detector With Lateral Sides Readout for Compton PET
Although Positron Emission Tomography is probably the most specific molecular imaging modality, it still lacks of a high detection sensitivity. One way of improving this is by implementing larger axial scanners and, therefore, increasing the solid angle coverage. Alternatively, it is possible to increase the sensitivity gain by improving the timing capabilities of the detectors. However, from the most fundamental nature of particle interactions with matter, the 511 keV gamma-rays suffer, in most of the cases, from scatter collisions either in the patient or within the detector block, before a photoelectric event eventually occurs. Recovering all scattered (Compton) events would improve scanner sensitivity. In this work we show the performance of a detector block geometry suitable for the development of PET scanners based on several detector layers. A geometry using multiple layers favor the process of scattered events, at the time that allows one for their proper identification. The detector block consists of a LYSO crystal with 51.5×51.5 mm2 surface and 3 mm thickness, resulting in a very high aspect ratio above 17. Four custom-made SiPM arrays of 1×16 elements with 3×3 mm2 area each are coupled to the lateral sides of the crystal. Four different methods to estimate the gamma-ray interaction position using the information collected by the four SiPM arrays have been implemented and compared in order to assess the most suitable one for this detector configuration and aspect ratio. A novel calibration method based on Voronoi diagrams has been successfully implemented, allowing us to recover data for the entire detector block. We have reached an intrinsic spatial resolution for the whole block of less than 1.6 mm FWHM, combined with an energy resolution of 12.1%. We have also compared the performance results with detector blocks using the same crystal but employing the standard backreading approach. Similar results were obtained but making use of 4 times less SiPM active area in the case of the lateral reading compared to the backreading method, and with the possibility to minimize the undesirable scatter in the photosensor layers.