Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style
- 10 January 2017
- journal article
- orthopaedic heritage
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 619-624
Abstract
Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.Keywords
This publication has 27 references indexed in Scilit:
- The Burden of Hip Osteoarthritis in the United States: Epidemiologic and Economic ConsiderationsJournal of the American Academy of Orthopaedic Surgeons, 2013
- Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocationOrthopaedics & Traumatology: Surgery & Research, 2012
- Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hipsInternational Orthopaedics, 2011
- Posterior approach and dislocation rate: A 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesisOrthopaedics & Traumatology: Surgery & Research, 2011
- The dual mobility socket concept: experience with 668 casesInternational Orthopaedics, 2010
- Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fractureBMC Musculoskeletal Disorders, 2010
- The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 yearsInternational Orthopaedics, 2008
- Dual Mobility Cemented Cups Have Low Dislocation Rates in THA RevisionsClinical Orthopaedics and Related Research, 2008
- An Analysis of the Risk of Hip Dislocation with a Contemporary Total Joint RegistryClinical Orthopaedics and Related Research, 2006
- Displaced Femoral Neck Fractures in the ElderlyClinical Orthopaedics and Related Research, 2001