Quench Performance of the First Pre-Series AUP Cryo-Assembly
- 14 February 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
Abstract
The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include eight cryo-assemblies that are expected to be fabricated and delivered to CERN by the US HL-LHC Accelerator Upgrade Project (AUP) as part of the U.S. contributions to the HL-LHC. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 and Q3 inner triplet optical elements in front of the two interaction points. Each cryo-assembly consists of two 4.2 m long Nb 3 Sn quadrupole magnets with aperture 150 mm and operating gradient 132.6 T/m. The first pre-series cryo-assembly has been fabricated and successfully tested at the horizontal test facility at Fermi National Accelerator Laboratory. In this manuscript we report the quench test results of the LQXFA/B-01 cryo-assembly. The primary objective of the horizontal test is full cryo-assembly qualification and validation of the performance requirements.Keywords
All Related Versions
Funding Information
- U.S. Department of Energy
- Office of Science
- High Energy Physics
- US LHC Accelerator Upgrade
This publication has 12 references indexed in Scilit:
- AUP First Pre-Series Cryo-Assembly Design Production and Test OverviewIEEE Transactions on Applied Superconductivity, 2024
- AUP First Pre-series Cold Mass Installation Into the CryostatIEEE Transactions on Applied Superconductivity, 2024
- Fermilab's Horizontal Test Stand Upgrade Overview and CommissioningIEEE Transactions on Applied Superconductivity, 2023
- Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at FermilabIEEE Transactions on Applied Superconductivity, 2023
- Fabrication of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade ProjectIEEE Transactions on Applied Superconductivity, 2023
- Test Results of the First Pre-Series Quadrupole Magnets for the LHC Hi-Lumi UpgradeIEEE Transactions on Applied Superconductivity, 2021
- U.S. HL-LHC Accelerator Upgrade Project: Q1/Q3 Cryostat Assembly and Horizontal Test (Final Design Report)2020
- Overview of the Quench Heater Performance for MQXF, the Nb3Sn Low-β Quadrupole for the High Luminosity LHCIEEE Transactions on Applied Superconductivity, 2018
- New 30 kA Power System at Fermilab and Its Use for Measuring the Effects of Ripple Current on the Performance of Superconducting High Field MagnetsIEEE Transactions on Applied Superconductivity, 2005
- A Cryogenic Test Stand for LHC Quadrupole MagnetsAIP Conference Proceedings, 2004