Valdas Eidukynas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Valdas Eidukynas has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Andrius Chaziachmetovas
Electronics Engineering Department, Kaunas University of Technology, Kaunas, Lithuania
3 shared publications - Linas Svilainis
Electronics Engineering Department, Kaunas University of Technology, Kaunas, Lithuania
3 shared publications - Virginija Gyliene
Faculty of Mechanical Engineering and Design, Kaunas University of Technology, Studentu str. 56, LT-51424 Kaunas, Lithuania
3 shared publications A. Bubulis
1 shared publicationAdrien Baldit
Laboratory of Mechanics, Physics and Mathematics, Ecole Nationale d'Ingenieurs de Metz, University of Lorraine, Metz, France
1 shared publicationAlgimantas Juozas Poška
1 shared publication
Latest Publications
- Open Access
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (9) , 1132-1140
Self-Test of Air-Coupled Probe for Sensitivity Map Production Using Parabolic Reflector
Spatial distribution of a transduction efficiency over the air-coupled probe surface was proposed as a convenient tool for the probe integrity inspection. In this research, a parabolic reflector is used for passive focusing of the acoustic wave on the surface of inspected probe. Therefore, no additional transducer is required for inspection: probe is used for self-inspection. This approach allows to avoid the expensive focused transducer and replaces it by same type air coupled transducers as probe under test. Moreover, use of the parabolic mirror for focusing is frequency-independent, therefore such approach allows to inspect a wide range of the probes. Spread spectrum signals were used for excitation to improve the SNR and bandwidth coverage. Results of the experimental measurements of air-coupled transducer sensitivity map with natural and artificial defects implemented have been presented. Comparison with previously proposed techniques is given. It was found that defects presence distorts the focused beam, creating large sidelobes. Therefore sensitivity map obtained with proposed technique is lower quality than with previously proposed techniques. Beam profile measurements using a miniature microphone have been presented. Aperture-limiting mask has been proposed to reduce the sidelobes arising due to defects presence and resulting measurements quality has been improved.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (9) , 1132-1140
Open AccessSelf-Test of Air-Coupled Probe for Sensitivity Map Production Using Parabolic Reflector
Spatial distribution of a transduction efficiency over the air-coupled probe surface was proposed as a convenient tool for the probe integrity inspection. In this research, a parabolic reflector is used for passive focusing of the acoustic wave on the surface of inspected probe. Therefore, no additional transducer is required for inspection: probe is used for self-inspection. This approach allows to avoid the expensive focused transducer and replaces it by same type air coupled transducers as probe under test. Moreover, use of the parabolic mirror for focusing is frequency-independent, therefore such approach allows to inspect a wide range of the probes. Spread spectrum signals were used for excitation to improve the SNR and bandwidth coverage. Results of the experimental measurements of air-coupled transducer sensitivity map with natural and artificial defects implemented have been presented. Comparison with previously proposed techniques is given. It was found that defects presence distorts the focused beam, creating large sidelobes. Therefore sensitivity map obtained with proposed technique is lower quality than with previously proposed techniques. Beam profile measurements using a miniature microphone have been presented. Aperture-limiting mask has been proposed to reduce the sidelobes arising due to defects presence and resulting measurements quality has been improved.
- 28 November 2023
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 416
FE modeling of the reconstructed Bituminated radioactive waste storage of Ignalina NPP
- 28 November 2023
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 416
FE modeling of the reconstructed Bituminated radioactive waste storage of Ignalina NPP
- Open Access
- 4 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3392-3401
Miniature Ferroelectret Microphone Design and Performance Evaluation Using Laser Excitation
Miniature microphones suitable for measurements of ultrasonic wave field scans in air are expensive or lack sensitivity or do not cover the range beyond 100 kHz. It is essential that they are too large for such fields measurements. The use of a ferroelectret (FE) film is proposed to construct a miniature, needle-style 0.5-mm-diameter sensitive element ultrasonic microphone. FE has an acoustic impedance much closer to that of air compared with other alternatives and is low cost and easy to process. The performance of the microphone was evaluated by measuring the sensitivity area map, directivity, ac response, and calibrating the absolute sensitivity. Another novel contribution here is that the sensitivity map was obtained by scanning the focused beam of a laser diode over the microphone surface, producing thermoelastic ultrasound excitation. The electroacoustic response of the microphone served as a sensitivity indicator at a scan spot. Micrometer scale granularity of the FE sensitivity was revealed in the sensitivity map images. It was also demonstrated that the relative ac response of the microphone can be obtained using pulsed laser beam thermoelastic excitation of the whole microphone surface with a laser diode. The absolute sensitivity calibration was done using the hybrid three-transducer reciprocity technique. A large aperture, air coupled transducer beam was focused onto the microphone surface, using the parabolic off-axis mirror. This measurement validated the laser ac response measurements. The FE microphone performance was compared with biaxially stretched polyvinylidene difluoride (PVDF) microphone of the same construction.
- 4 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3392-3401
Open AccessMiniature Ferroelectret Microphone Design and Performance Evaluation Using Laser Excitation
Miniature microphones suitable for measurements of ultrasonic wave field scans in air are expensive or lack sensitivity or do not cover the range beyond 100 kHz. It is essential that they are too large for such fields measurements. The use of a ferroelectret (FE) film is proposed to construct a miniature, needle-style 0.5-mm-diameter sensitive element ultrasonic microphone. FE has an acoustic impedance much closer to that of air compared with other alternatives and is low cost and easy to process. The performance of the microphone was evaluated by measuring the sensitivity area map, directivity, ac response, and calibrating the absolute sensitivity. Another novel contribution here is that the sensitivity map was obtained by scanning the focused beam of a laser diode over the microphone surface, producing thermoelastic ultrasound excitation. The electroacoustic response of the microphone served as a sensitivity indicator at a scan spot. Micrometer scale granularity of the FE sensitivity was revealed in the sensitivity map images. It was also demonstrated that the relative ac response of the microphone can be obtained using pulsed laser beam thermoelastic excitation of the whole microphone surface with a laser diode. The absolute sensitivity calibration was done using the hybrid three-transducer reciprocity technique. A large aperture, air coupled transducer beam was focused onto the microphone surface, using the parabolic off-axis mirror. This measurement validated the laser ac response measurements. The FE microphone performance was compared with biaxially stretched polyvinylidene difluoride (PVDF) microphone of the same construction.
- Open Access
Numerical Analysis of Stapes Prosthesis Constraining in the Case of Otosclerosis
In the case of otosclerosis, it has been noticed that even though there are a variety of different prostheses on the market, due to the anatomical characteristics, it is not always possible to restore excellent mobility to the ossicles and the prosthesis. On the one hand, this happens because the incus long process and the prosthesis create difficult angles. On the other hand, incus necrosis is among the most common causes of the loss of stability to the prosthesis and stapedectomy failure. The aim of this research is to suggest an improvement for stapes prosthesis stability and numerically evaluate the impact of the prosthesis constraining to its dynamical behavior. Numerical 3D models of a standard as well as a modified (adjustable angled) stapes prosthesis were created in order to achieve this aim. Consequently, the modal analysis has been performed to evaluate the mechanical behavior of the prosthesis, assuming that the piston (thick part) would be made of Teflon, and the thin part, fixated on the incus long process, would be made from titanium alloy. Finally, the numerical analysis has been conducted by changing the boundary conditions in respect of the prosthesis constraining, where the attached stapes prosthesis connects to the ossicular chain. Subsequently, there were two hypotheses raised for the prosthesis loop constraining. The first is that during the surgery, the prosthesis is perfectly crimped with certain looseness. The second is that the prosthesis is outgrown by the tissues over time and thus becomes over-constrained. Then, the analyzed standard stapes prosthesis does not fulfil its functions because of the over-constraining that develops over time. An improvement for the standard stapes prosthesis, i.e., a modified stapes prosthesis (adjustable angled), that has been proposed in this research allows avoidance of the negative effects of the over-constrained standard stapes prosthesis that appear over time. Moreover, the proposed modified prosthesis helps to regain hearing when the angle between the incus long process and prosthesis is unfavorable.
Open AccessNumerical Analysis of Stapes Prosthesis Constraining in the Case of Otosclerosis
In the case of otosclerosis, it has been noticed that even though there are a variety of different prostheses on the market, due to the anatomical characteristics, it is not always possible to restore excellent mobility to the ossicles and the prosthesis. On the one hand, this happens because the incus long process and the prosthesis create difficult angles. On the other hand, incus necrosis is among the most common causes of the loss of stability to the prosthesis and stapedectomy failure. The aim of this research is to suggest an improvement for stapes prosthesis stability and numerically evaluate the impact of the prosthesis constraining to its dynamical behavior. Numerical 3D models of a standard as well as a modified (adjustable angled) stapes prosthesis were created in order to achieve this aim. Consequently, the modal analysis has been performed to evaluate the mechanical behavior of the prosthesis, assuming that the piston (thick part) would be made of Teflon, and the thin part, fixated on the incus long process, would be made from titanium alloy. Finally, the numerical analysis has been conducted by changing the boundary conditions in respect of the prosthesis constraining, where the attached stapes prosthesis connects to the ossicular chain. Subsequently, there were two hypotheses raised for the prosthesis loop constraining. The first is that during the surgery, the prosthesis is perfectly crimped with certain looseness. The second is that the prosthesis is outgrown by the tissues over time and thus becomes over-constrained. Then, the analyzed standard stapes prosthesis does not fulfil its functions because of the over-constraining that develops over time. An improvement for the standard stapes prosthesis, i.e., a modified stapes prosthesis (adjustable angled), that has been proposed in this research allows avoidance of the negative effects of the over-constrained standard stapes prosthesis that appear over time. Moreover, the proposed modified prosthesis helps to regain hearing when the angle between the incus long process and prosthesis is unfavorable.
- Open Access
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-15
Compact Laser Driver for Ultrasonic Arbitrary Position and Width Pulse Sequences Generation
Laser ultrasound offers several benefits in comparison to immersion or air-coupled ultrasound: it directly generates stress on the sample surface; it has a wide bandwidth and a small acoustic source can be produced. Conventionally, high-power pulsed lasers are required therefore equipment is bulky and expensive. Here we propose to use mid-power laser diodes, which are small and low cost. To solve the low signal amplitude problem with lower power lasers, the use of spread spectrum signal, arbitrary position, and width binary pulse sets is proposed. To date, a laser driver for this task has not been available. This article describes the development of such a compact driver, where the essential electronics occupy an area of $10\,\,\times20$ mm. The whole system with a fixture for kinematic mount is comparable in size to a conventional piezoelectric ultrasonic transducer. The driver can supply pulse sets of up to 40 A. Individual pulse duration can vary between 20 and 1000 ns (0.5–25-MHz ultrasound range) and the total pulse train duration is limited by the laser type used. Experiments show that up to 10- $\mu \text{s}$ long pulse sets can be used at 10-A current, without laser degradation. Current waveforms, beam profile, and optical response signals were measured for three rectified topologies. It was concluded that the GaN-based constant current switch topology has the best performance, but a power MOSFET in a source current feedback topology can also be used to generate pulses down to 20 ns. Photoacoustic response signals from chirp and phase shift keying modulation have been demonstrated.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-15
Open AccessCompact Laser Driver for Ultrasonic Arbitrary Position and Width Pulse Sequences Generation
Laser ultrasound offers several benefits in comparison to immersion or air-coupled ultrasound: it directly generates stress on the sample surface; it has a wide bandwidth and a small acoustic source can be produced. Conventionally, high-power pulsed lasers are required therefore equipment is bulky and expensive. Here we propose to use mid-power laser diodes, which are small and low cost. To solve the low signal amplitude problem with lower power lasers, the use of spread spectrum signal, arbitrary position, and width binary pulse sets is proposed. To date, a laser driver for this task has not been available. This article describes the development of such a compact driver, where the essential electronics occupy an area of $10\,\,\times20$ mm. The whole system with a fixture for kinematic mount is comparable in size to a conventional piezoelectric ultrasonic transducer. The driver can supply pulse sets of up to 40 A. Individual pulse duration can vary between 20 and 1000 ns (0.5–25-MHz ultrasound range) and the total pulse train duration is limited by the laser type used. Experiments show that up to 10- $\mu \text{s}$ long pulse sets can be used at 10-A current, without laser degradation. Current waveforms, beam profile, and optical response signals were measured for three rectified topologies. It was concluded that the GaN-based constant current switch topology has the best performance, but a power MOSFET in a source current feedback topology can also be used to generate pulses down to 20 ns. Photoacoustic response signals from chirp and phase shift keying modulation have been demonstrated.
- Open Access
An Analysis of the Reliability of a Bus Safety Structure on Carrying Out the Numerical and Experimental Tests
In the paper, the reliability of a spatial tubular structure of a bus safety frame formed of different steel profiles is discussed. A methodology for the bus safety structure modeling is presented herein by applying numerical methods that enable us to simulate virtually a test for assessing bus rollover crashworthiness according to the United Nations Economic Commission for Europe (UNECE) Regulation No. 66, and also to assess and ensure the reliability and safety of the structure under operating conditions. The simulation has been performed by applying the mixed method of kinematical analysis and finite elements. In the course of the calculations, physical and geometrical non-linearity of materials was assessed. In addition, an experimental rollover test according to UNECE Regulation No. 66 was performed in this work, striving to verify the provided methodology for modeling by applying numerical methods. For the experiment, an identical safety structure and a rollover stand (identical to the one used in modeling) were used. The rollover test was shot by a Phantom v711 high-speed camera. In the paper, the results of kinematical and dynamic analysis from applying the finite element method and the ones of the experimental test, as well as their comparisons, are provided. It is assessed whether the developed safety structure model is reliable and suitable for use.
Open AccessAn Analysis of the Reliability of a Bus Safety Structure on Carrying Out the Numerical and Experimental Tests
In the paper, the reliability of a spatial tubular structure of a bus safety frame formed of different steel profiles is discussed. A methodology for the bus safety structure modeling is presented herein by applying numerical methods that enable us to simulate virtually a test for assessing bus rollover crashworthiness according to the United Nations Economic Commission for Europe (UNECE) Regulation No. 66, and also to assess and ensure the reliability and safety of the structure under operating conditions. The simulation has been performed by applying the mixed method of kinematical analysis and finite elements. In the course of the calculations, physical and geometrical non-linearity of materials was assessed. In addition, an experimental rollover test according to UNECE Regulation No. 66 was performed in this work, striving to verify the provided methodology for modeling by applying numerical methods. For the experiment, an identical safety structure and a rollover stand (identical to the one used in modeling) were used. The rollover test was shot by a Phantom v711 high-speed camera. In the paper, the results of kinematical and dynamic analysis from applying the finite element method and the ones of the experimental test, as well as their comparisons, are provided. It is assessed whether the developed safety structure model is reliable and suitable for use.
- 3 March 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234 (3) , 265-272
Characterization of mechanical behaviour of healthy and injured human incus by eigenfrequency evaluation
The usage of finite element method techniques gives a possibility to replace time-consuming experiments or imitate physical process in the ear by numerical simulation. Especially, the research of spatial motion of ossicular chain in the middle ear is of high interest for the oto-surgeons and engineers. It is known that the most affected bone from the ossicular chain is the incus. After the cholesteatoma operation and tympanoplasty, the affected incus is removed or sacrificed; thus, the possibility of transducing noise lays on the stapes, new titanium or other material prosthesis. In this case, the affected incus was removed because of the cholesteatoma that was lying in front of it in the tympanic cavity. The removed incus with the affected long process passed micro–computed tomography. The computer-aided design systems allowed redesigning a ‘healthy’ incus with an intact long process. In this way, it was possible to evaluate the influence of damaged long process of incus in the vibrational analysis. This article analyses the problems of mechanical behaviour of injured and healthy human incus. The numerical simulation has demonstrated that the features of healthy incus and analysed injured incus do not differ significantly, especially at low (about 500 Hz) frequencies. It explains why there is no impact of cholesteatoma on hearing for a long time in the audiogram.
- 3 March 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234 (3) , 265-272
Characterization of mechanical behaviour of healthy and injured human incus by eigenfrequency evaluation
The usage of finite element method techniques gives a possibility to replace time-consuming experiments or imitate physical process in the ear by numerical simulation. Especially, the research of spatial motion of ossicular chain in the middle ear is of high interest for the oto-surgeons and engineers. It is known that the most affected bone from the ossicular chain is the incus. After the cholesteatoma operation and tympanoplasty, the affected incus is removed or sacrificed; thus, the possibility of transducing noise lays on the stapes, new titanium or other material prosthesis. In this case, the affected incus was removed because of the cholesteatoma that was lying in front of it in the tympanic cavity. The removed incus with the affected long process passed micro–computed tomography. The computer-aided design systems allowed redesigning a ‘healthy’ incus with an intact long process. In this way, it was possible to evaluate the influence of damaged long process of incus in the vibrational analysis. This article analyses the problems of mechanical behaviour of injured and healthy human incus. The numerical simulation has demonstrated that the features of healthy incus and analysed injured incus do not differ significantly, especially at low (about 500 Hz) frequencies. It explains why there is no impact of cholesteatoma on hearing for a long time in the audiogram.
- 1 January 2019
- Published by Elsevier in Precision Engineering
- Vol. 55, 361-375
Investigation of a 1-DOF piezoelectric micro-positioning rotary stage
- 1 January 2019
- Published by Elsevier in Precision Engineering
- Vol. 55, 361-375
Investigation of a 1-DOF piezoelectric micro-positioning rotary stage
- 6 February 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 231 (3) , 222-234
Assessment of bicycle–car accidents under four different types of collision
Bicycle riders are among the highest risk group in traffic. A cyclist simulation study captured kinematics and injuries to legs, pelvis, neck, and head for one human body size. We analyzed the number of parameters (forces acting on left and right tibia, head injury criterion, neck tensile force, neck shear force, and pelvic acceleration) for each of the four different cases: bicyclist ride out—residential driveway, motorist overtaking—undetected bicyclist, bicyclist left turn—same direction, and bicyclist right turn—opposite direction. The comparison of simulation outcomes for leg injuries with official hospital records has shown a very good correlation in terms of injury severity prediction. This study concludes that if countermeasures to prevent fatal cyclist injury in car impacts were to be concentrated on mitigating head and neck impact to the windscreen of the car, a dominant share of fatal cyclist crashes and severe traumatic head injury cases at collision speeds exceeding 40 km/h could be prevented.
- 6 February 2017
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 231 (3) , 222-234
Assessment of bicycle–car accidents under four different types of collision
Bicycle riders are among the highest risk group in traffic. A cyclist simulation study captured kinematics and injuries to legs, pelvis, neck, and head for one human body size. We analyzed the number of parameters (forces acting on left and right tibia, head injury criterion, neck tensile force, neck shear force, and pelvic acceleration) for each of the four different cases: bicyclist ride out—residential driveway, motorist overtaking—undetected bicyclist, bicyclist left turn—same direction, and bicyclist right turn—opposite direction. The comparison of simulation outcomes for leg injuries with official hospital records has shown a very good correlation in terms of injury severity prediction. This study concludes that if countermeasures to prevent fatal cyclist injury in car impacts were to be concentrated on mitigating head and neck impact to the windscreen of the car, a dominant share of fatal cyclist crashes and severe traumatic head injury cases at collision speeds exceeding 40 km/h could be prevented.
- 26 October 2015
- Published by Kaunas University of Technology (KTU) in Mechanics
- Vol. 21 (5)
Dynamics of the large opening fire valves of dust explosions automatic localization systems
The paper analyzes the possibility to use automatic slide-gate type fire dampers with multiple blades superposed with the linear induction motor secondary elements in dust explosions localization system with large cross-secion ductworks. Sheet metal type blades stress-strain state computations by means of finite element method and studies of dynamics of fire dampers linear electic actuators by means of Matlab Simulink computer model were performed. It was obtained that the dampers blades thickness minimization reduces their response time about two times, closing force - near 30%.DOI: http://dx.doi.org/10.5755/j01.mech.21.5.11759
- 26 October 2015
- Published by Kaunas University of Technology (KTU) in Mechanics
- Vol. 21 (5)
Dynamics of the large opening fire valves of dust explosions automatic localization systems
The paper analyzes the possibility to use automatic slide-gate type fire dampers with multiple blades superposed with the linear induction motor secondary elements in dust explosions localization system with large cross-secion ductworks. Sheet metal type blades stress-strain state computations by means of finite element method and studies of dynamics of fire dampers linear electic actuators by means of Matlab Simulink computer model were performed. It was obtained that the dampers blades thickness minimization reduces their response time about two times, closing force - near 30%.DOI: http://dx.doi.org/10.5755/j01.mech.21.5.11759