Development of Conductometric Sensor Based on 25,27-Di-(5-thio-octyloxy)calix[4]arene-crown-6 for Determination of Ammonium
Open Access
- 25 February 2016
- journal article
- research article
- Published by Springer Nature in Discover Nano
- Vol. 11 (1) , 1-10
Abstract
The conductometric sensor based on 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 was developed for the quantitative analysis of ammonium. The calixarene was immobilized on the surface of the planar interdigitated electrodes by attachment of its dialkyl sulfide groups to the surface of the gold electrodes. The intrinsic ability of the calixarene to capture ammonium was studied in the conductometric measuring mode and by the electrochemical impedance spectroscopy. The developed sensor showed high selectivity to ammonium in the presence of mono-, di-, and trivalent cations. Selective and highly sensitive detection of ammonium resulted from the complexation between the ammonium ions and a crown-ether fragment of the upper rim of the 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 macrocycle. The developed sensor had high signal repeatability. Its sensitivity was found to be satisfactory for the forthcoming sensor application in the water-sample analysis; the linear range was 0.01–1.5 mM and limit of detection 10 μM.Keywords
Funding Information
- National Academy of Sciences of Ukraine (Complex scientific-technical program “Sensor systems for medical-ecological and industrial purposes”)
This publication has 17 references indexed in Scilit:
- A Novel Highly Sensitive Zeolite-Based Conductometric Microsensor for Ammonium DeterminationAnalytical Letters, 2012
- A guide for selecting the most appropriate method for ammonium determination in water analysisTrAC Trends in Analytical Chemistry, 2006
- Conductometric enzyme biosensors: theory, technology, applicationBiopolymers and Cell, 2005
- Amperometric determination of ammonium with bienzyme/poly(carbamoyl) sulfonate hydrogel-based biosensorSensors and Actuators B: Chemical, 2004
- Ammonium ion sensor based on photocured and self-plasticising acrylic films for the analysis of sewageSensors and Actuators B: Chemical, 2004
- Selectivity of Potentiometric Ion SensorsAnalytical Chemistry, 2000
- Molecular engineering. Part 2.1 Influence of side-chain substituents in lariat-type upper-rim calix[4]crowns on their binding properties and the reversal of theseJournal of the Chemical Society, Perkin Transactions 1, 1997
- Synthesis and Binding Property of Tunable Upper-Rim Calix[4]crownsChemistry Letters, 1996
- Bridged calix[6]arenes in the cone conformation: New receptors for quaternary ammonium cationsTetrahedron, 1995
- Working with Ion-Selective Electrodes1979