Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Viktoriya M. Pyeshkova has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel Conductometric Chemosensor Based on Methylenebis(Phosphonic Acid)-Modified Calixarene for L-Arginine Determination

    by Svitlana V. Marchenko, Sergiy O. Cherenok, Kseniia O. Berketa, Veronika A. Bakhmat, Olha V. Soldatkina, Anna I. Selikhova, Olga I. Kalchenko, Galyna P. Volynets, Oleksandr O. Soldatkin, Vitaly I. Kalchenko, et al.

    This study reports the synthesis of a novel methylenebisphosphonic acid calix[4]arene derivative and its application as a receptor layer in a conductometric chemosensor for the highly sensitive detection of L-arginine. The synthesized calixarene contains two methylenebisphosphonic acid fragments at the upper rim of the macrocycle, which serve as recognition sites for L-arginine, and two 3-(methylthio)propoxy groups at the lower rim, which enable immobilization on the gold electrode surface. The sensor based on synthesized calixarene demonstrated a pronounced response to L-arginine, which can be attributed to the cooperative interaction of the protonated amino and guanidinium groups of L-arginine with the methylenebisphosphonic acid groups of the calixarene receptor. Density functional theory (DFT) calculations were employed to elucidate the molecular interactions underlying the recognition of L-arginine by the calixarene receptor. The developed chemosensor demonstrated a low limit of detection for L-arginine (5.6 µM); a wide linear range (up to 1000 μM); a short response time (≤80 s); and a high response reproducibility (RSD = 1.3%). The stability constants determined by HPLC depended on the nature of the amino acid and ranged from logKA = 4.26 for leucine to logKA = 4.52 for L-arginine. Compared with previously reported L-arginine sensors, the developed conductometric chemosensor exhibits a competitive detection limit, a wider linear detection range, and significantly improved response reproducibility. The proposed calixarene-based chemosensor enables simple, highly sensitive, enzyme-free conductometric detection of L-arginine over a broad concentration range in aqueous solutions.

  • Open Access

    Development of a Highly Sensitive SPR Biosensor for BCR–ABL Gene Sequence Detection Using a Novel Gold Nanoparticle–Enhanced Sandwich Assay Format

    by Maksym S. Sobolevskyi, Andrii M. Lopatynskyi, Anton V. Samoylov, Glib V. Dorozinsky, Oleksandr M. Lyapin, Roman V. Khrystosenko, Volodymyr I. Chegel, Viktoriya M. Pyeshkova, Abdelhamid Errachid, Sergei V. Dzyadevych, et al.

    SPR (surface plasmon resonance) biosensor–based analytical methods enable rapid, straightforward, and cost-effective detection of DNA oligonucleotides. However, the detection limits of currently available SPR biosensors for BCR–ABL gene oligonucleotides remain too high to reliably detect sub-nanomolar concentrations. This study presents a new signal-enhancement approach for SPR DNA biosensors based on a gold nanoparticle (AuNP) sandwich assay. In this work, we demonstrated that AuNP-modified oligonucleotides can serve as labels that significantly amplify the SPR biosensor response in a sandwich-type SPR DNA biosensor. The analytical characteristics of the developed AuNP-labeled biosensor for detection of BCR–ABL fusion gene oligonucleotides were studied. The AuNP-labeled biosensor exhibited a detection limit of 80 pM, which is significantly lower than that of a traditional label-free SPR biosensor (50 nM). The measurement error for BCR–ABL target detection was significantly lower with the AuNP-labeled biosensor than with the label-free SPR biosensor. The conditions of synthesis of AuNPs by citrate reduction of AuCl3 that allow the monodisperse size distribution and absence of AuNP aggregation were established as well. Based on the obtained data, we conclude that a sandwich assay employing AuNP-modified oligonucleotides as labels is a promising approach for the highly sensitive detection of genetic markers. The developed AuNP-labeled DNA biosensing approach can be adapted to enhance the signal in other DNA hybridization-based SPR biosensors.


  • Open Access

    Development and Comparative Evaluation of Two Enzyme-Based Amperometric Biosensor Designs for Alanine Aminotransferase Determination in Biological Fluids

    by Daryna Mruga, Yevhen Vakhovskyi, Veronika Bakhmat, Viktoriya Pyeshkova, Sergii Dzyadevych, Oleksandr Soldatkin

    Alanine aminotransferase (ALT) is a key biomarker of liver function. Compared with conventional assays for ALT detection—which are expensive, time-consuming, labor-intensive, and require experienced personnel—biosensors represent a promising alternative, but it remains unclear which biorecognitive enzymatic configuration offers the best analytical performance for ALT detection. This study presents the development and comparative evaluation of two amperometric biosensors based on oxidase biorecognition elements: pyruvate oxidase (POx) and glutamate oxidase (GlOx). Enzymes were immobilized onto platinum electrodes under optimized conditions using entrapment for POx (pH 7.4, enzyme loading 1.62 U/µL, PVA-SbQ concentration 13.2%) and covalent crosslinking for GlOx (pH 6.5, enzyme loading 2.67%, glutaraldehyde concentration 0.3%). Analytical parameters were systematically assessed, including linear range (1–500 U/L for POx vs. 5–500 U/L for GlOx), limit of detection (1 U/L for both), and sensitivity (0.75 vs. 0.49 nA/min at 100 U/L). The POx-based biosensor demonstrated higher sensitivity and lower detection limits, whereas the GlOx-based biosensor exhibited greater stability in complex solutions and reduced assay costs due to a simpler working solution. Moreover, while the POx-based system is uniquely suited for ALT determination, the GlOx-based sensor can be affected by AST activity in samples but may also be adapted for targeted AST detection. Overall, the study highlights a trade-off between sensitivity, robustness, and versatility in ALT biosensor design, providing guidance for the rational development of clinically relevant devices.

  • Development of three-enzyme lactose amperometric biosensor modified by nanosized poly (meta-phenylenediamine) film

    by V. M. Pyeshkova, O. Y. Dudchenko, O. O. Soldatkin, S. A. Alekseev, T. Seker, B. Akata Kurc, S. V. Dzyadevych


  • Open Access

    Improvement of amperometric transducer selectivity using nanosized phenylenediamine films

    by O. V. Soldatkina, I. S. Kucherenko, V. M. Pyeshkova, S. A. Alekseev, O. O. Soldatkin, S. V. Dzyadevych

    In this work, we studied the conditions of deposition of a semipermeable polyphenylenediamine (PPD)-based membrane on amperometric disk platinum electrodes. Restricting an access of interfering substances to the electrode surface, the membrane prevents their impact on the sensor operation. Two methods of membrane deposition by electropolymerization were compared—at varying potential (cyclic voltammetry) and at constant potential. The cyclic voltammetry was shown to be easier in performing and providing better properties of the membrane. The dependence of PPD membrane effectiveness on the number of cyclic voltammograms and phenylenediamine concentration was analyzed. It was shown that the impact of interfering substances (ascorbic acid, dopamine, cysteine, uric acid) on sensor operation could be completely avoided using three cyclic voltammograms in 30 mM phenylenediamine. On the other hand, when working with diluted samples, i.e., at lower concentrations of electroactive substances, it is reasonable to decrease the phenylenediamine concentration to 5 mM, which would result in a higher sensitivity of transducers to hydrogen peroxide due to a thinner PPD layer. The PPD membrane was tested during continuous operation and at 8-day storage and turned out to be efficient in sensor and biosensors.


  • Open Access

    Development of Conductometric Sensor Based on 25,27-Di-(5-thio-octyloxy)calix[4]arene-crown-6 for Determination of Ammonium

    by O. Y. Saiapina, S. G. Kharchenko, S. G. Vishnevskii, V. M. Pyeshkova, V. I. Kalchenko, S. V. Dzyadevych

    The conductometric sensor based on 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 was developed for the quantitative analysis of ammonium. The calixarene was immobilized on the surface of the planar interdigitated electrodes by attachment of its dialkyl sulfide groups to the surface of the gold electrodes. The intrinsic ability of the calixarene to capture ammonium was studied in the conductometric measuring mode and by the electrochemical impedance spectroscopy. The developed sensor showed high selectivity to ammonium in the presence of mono-, di-, and trivalent cations. Selective and highly sensitive detection of ammonium resulted from the complexation between the ammonium ions and a crown-ether fragment of the upper rim of the 25,27-di-(5-thio-octyloxy)calix[4]arene-crown-6 macrocycle. The developed sensor had high signal repeatability. Its sensitivity was found to be satisfactory for the forthcoming sensor application in the water-sample analysis; the linear range was 0.01–1.5 mM and limit of detection 10 μM.


  • Open Access

    Development of Silicalite/Glucose Oxidase-Based Biosensor and Its Application for Glucose Determination in Juices and Nectars

    by Oleksandr Ye Dudchenko, Viktoriya M. Pyeshkova, Oleksandr O. Soldatkin, Burcu Akata, Berna O Kasap, Alexey P. Soldatkin, Sergei V. Dzyadevych

    The application of silicalite for improvement of enzyme adsorption on new stainless steel electrodes is reported. Glucose oxidase (GOx) was immobilized by two methods: cross-linking by glutaraldehyde (GOx-GA) and cross-linking by glutaraldehyde along with GOx adsorption on silicalite-modified electrode (SME) (GOx-SME-GA). The GOx-SME-GA biosensors were characterized by a four- to fivefold higher sensitivity than GOx-GA biosensor. It was concluded that silicalite together with GA sufficiently enhances enzyme adhesion on stainless steel electrodes. The developed GOx-SME-GA biosensors were characterized by good reproducibility of biosensor preparation (relative standard deviation (RSD)—18 %), improved signal reproducibility (RSD of glucose determination was 7 %), and good storage stability (29 % loss of activity after 18-day storage). A series of fruit juices and nectars was analyzed using GOx-SME-GA biosensor for determination of glucose concentration. The obtained results showed good correlation with the data of high-performance liquid chromatography (HPLC) (R = 0.99).


  • Open Access

    Application of silicalite-modified electrode for the development of sucrose biosensor with improved characteristics

    by Viktoriya M Pyeshkova, Oleksandr Y Dudchenko, Oleksandr O Soldatkin, Berna Ozansoy Kasap, Florence Lagarde, Burcu Akata Kurç, Sergei V Dzyadevych

    The application of silicalite for improvement of working characteristics of conductometric enzyme biosensors for determination of sucrose was studied in this research. Biosensors based on different types of silicalite-modified electrodes were studied and compared according to their analytical characteristics. Polyethylenimine/glutaraldehyde/silicalite-modified biosensors showed higher sensitivity compared with others type of biosensors. Moreover, the polyethylenimine/glutaraldehyde/silicalite sucrose biosensors were characterized by high selectivity and signal reproducibility (relative standard deviation (RSD) = 2.78% for glucose measurements and RSD = 3.2% for sucrose measurements). Proposed biosensors were used for determination of sucrose in different samples of beverages. The obtained results had good correlation with results obtained by HPLC. Thus, polyethylenimine/glutaraldehyde/silicalite-modified biosensors have shown perspective characteristics for the development of effective conductometric enzyme biosensors.


  • Open Access

    Application of silicalite for improvement of enzyme adsorption on the stainless steel electrodes

    by V. N. Pyeshkova, O. Y. Dudchenko, O. O. Soldatkin, I. S. Kucherenko, B. Ozansoy Kasap, B. Akata Kurc, S. V. Dzyadevych

    Aim. Improvement of analytical characteristics of an enzyme biosensor based on new inexpensive perspective stainless steel electrodes using silicalite nanoparticles. Methods. Conductometric enzyme biosensor was used. Results. Three methods of glucose oxidase (GOx) immobilization were studied and compared: GOx adsorption on silicalite modified electrodes (GOx-SME); cross-linking by glutaraldehyde without silicalite (GOx-GA); GOx adsorption on SME along with cross-linking by glutaraldehyde (GOx-SME-GA). The GOx-SME-GA biosensors based on stainless steel electrodes were characterized by 12–25-fold higher sensitivity comparing with other biosensors. The developed GOx-SME-GA biosensors were characterized by good reproducibility of glucose biosensors construction (relative standard deviation (RSD) – 18 %), improved signal reproducibility (RSD of glucose determination was 7 %) and good storage stability (29 % loss of activity after 18 days). Conclusions. The method of enzyme immobilization using silicalite together with GA cross-linking sufficiently enhances the enzyme adsorption on the stainless steel electrodes and improves the analytical parameters of biosensors. This method is found to be promising for further creation of other enzyme biosensors


  • Novel conductometric biosensor based on three-enzyme system for selective determination of heavy metal ions

    by O.O. Soldatkin, I.S. Kucherenko, V.M. Pyeshkova, A.L. Kukla, N. Jaffrezic-Renault, A.V. El'SKaya, S.V. Dzyadevych, A.P. Soldatkin