Abstract
The combined use of high‐performance fiber reinforced concrete (HPFRC) and prestressing systems in bridge construction offers significant advantages, including material and cost savings, as well as enhanced durability. However, the shear behavior of such elements remains still a topic of scientific debate. To advance understanding of this critical aspect, this paper presents the results of an experimental investigation conducted on eight full‐scale HPFRC beams without stirrups and with varying levels of prestressing. The experimental shear resistance is compared with predictions from EN1992‐1‐1:2023 (EC2:2023) to assess its accuracy. The results show that the EC2:2023 provisions are highly conservative, especially for beams with higher levels of prestressing, significantly underestimating the shear resistance. To further evaluate the accuracy of the EC2:2023 model, it is also compared with the experimental results collected from an extended database of shear tests on prestressed FRC beams without stirrups. Safety margin calculations demonstrate that the EC2:2023 shear formulation leads to few unsafe results, but with excessive conservatism (increasing for higher values of the prestress level). Notably, for some specimens, the predicted shear capacity is even lower than that of the same beam when fiber contributions are not considered. Finally, a similar analysis is performed with Level of Approximation II and III of Model Code 2020 (MC2020) showing a significant improvement on the shear resistance predictions.

This publication has 30 references indexed in Scilit: