A 2.63 μW ECG Processor With Adaptive Arrhythmia Detection and Data Compression for Implantable Cardiac Monitoring Device
- 27 July 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (4) , 777-790
Abstract
An ultra-low power ECG processor ASIC (application specific integrated circuit) with R-wave detection and data compression is presented, which is designed for the long-term implantable cardiac monitoring (ICM) device for arrhythmia diagnosis. An adaptive derivative-based detection algorithm with low computation overhead for potential arrhythmia recording is proposed to detect arrhythmia with the occasional abnormal heart beats. In order to save as much as possible cardiac information with the limited memory size available in the ICM device, a hierarchical data buffer structure is proposed which saves 3 types of data, including the raw ECG data segments of 2 seconds, compressed ECG data segments of 45 seconds, and R-peak values and interval lengths of >2000 beat cycles. A modified swinging-door-trending (SDT) method is proposed for the ECG data compression. The ASIC has been implemented based on fully-customized near-threshold standard cells using the thick-gate transistors in 65-nm CMOS technology for low dynamic power consumption and leakage. The ASIC core occupies a die area of 1.77 mm 2 . The measured total power is 2.63 μW, which is among the ECG processors with the lowest core power consumption. It exhibits a relatively high positive precision rate ( P + ) of 99.3% with a sensitivity of 98.2%, in contrast to the similar designs in literature with the same core power consumption level. Also, an ECG data compression ratio ( CR ) of up to 17.0 has been achieved, with a good trade-off between the compression efficiency and loss.Keywords
Funding Information
- NSFC-FDCT Joint Program (61661166010)
- Shenzhen Science and Technology Program (JCYJ20160608154932084, JSGG20191129141019090)
- Suzhou-Tsinghua Innovation Leadership Program (2016SZ0214)
This publication has 26 references indexed in Scilit:
- A 410-nW Efficient QRS Processor for Mobile ECG Monitoring in 0.18-μm CMOSIEEE Transactions on Biomedical Circuits and Systems, 2017
- A 3-Lead ECG-on-Chip with QRS Detection and Lossless Compression for Wireless SensorsIEEE Transactions on Circuits and Systems II: Express Briefs, 2016
- A Wearable Healthcare System With a 13.7 $\mu$ A Noise Tolerant ECG ProcessorIEEE Transactions on Biomedical Circuits and Systems, 2014
- An Injectable 64 nW ECG Mixed-Signal SoC in 65 nm for Arrhythmia MonitoringIEEE Journal of Solid-State Circuits, 2014
- Design of Wavelet-Based ECG Detector for Implantable Cardiac PacemakersIEEE Transactions on Biomedical Circuits and Systems, 2013
- Is Surface ECG a Useful Surrogate for Subcutaneous ECG?Pacing and Clinical Electrophysiology, 2010
- Detection of Heart Blocks in ECG Signals by Spectrum and Time-Frequency Analysis2006
- Hospital admission of patients referred to the Emergency Department for syncope: a single-hospital prospective study based on the application of the European Society of Cardiology Guidelines on syncopeEuropean Heart Journal, 2005
- An improved process data compression algorithm2003
- Incidence and Prognosis of SyncopeNew England Journal of Medicine, 2002