JRJan Ringkamp

Jan Ringkamp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Ringkamp has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Christian Siebauer

    Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany

    1 shared publication
  • Jens Langejuergen

    Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany

    1 shared publication
  • Jens Langejürgen

    Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, Theodor-Kutzer-Ufer 1–3 (Cubex41), 68167 Mannheim, Germany

    1 shared publication
  • Kirsten J. Dehning

    Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9a, 30167 Hannover, Germany

    1 shared publication
  • Lara-Jasmin Behrend

    Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany

    1 shared publication
  • Moritz Bednorz

    Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Theodor-Kutzer-Ufer 1-3 (Cubex41), 68167 Mannheim, Germany

    1 shared publication

Latest Publications

  • Open Access

    Reconstruction of Respiratory Flow from an Impedance-Based Contactless Sensor System

    by Moritz Bednorz, Jan Ringkamp, Lara-Jasmin Behrend, Philipp Lebhardt, Jens Langejürgen

    Conventional respiratory monitoring is often invasive, while most non-contact technologies like radar or cameras are limited to estimating respiratory rate, failing to reconstruct the detailed waveform of the respiratory flow itself. This gap limits their clinical utility for advanced diagnostics. We introduce a novel system that bridges this gap by combining a contactless, impedance-based sensor (the Thoraxmonitor) with a dedicated machine learning framework to directly reconstruct the full respiratory flow signal. Operating at 433 MHz, the system’s antenna array detects subtle changes in thoracic impedance, which are then translated into a quantitative flow signal by a Multilayer Perceptron Regressor. Based on data from 17 subjects benchmarked against a gold-standard flowmeter, our system accurately detected 98% of respiratory cycles. It achieved remarkable precision in timing respiratory events, with mean deviations of + 60 ms (±79 ms) for inspiration and + 50 ms (±63 ms) for expiration, making it suitable for time-critical applications. While a systematic bias in absolute tidal volume prediction currently limits inter-subject comparisons, the system excels at tracking relative intra-subject changes. Crucially, our model quantifies its own reliability, providing an intrinsic self-assessment mechanism. This work demonstrates a significant step beyond simple rate detection towards comprehensive, comfortable, and reliable respiratory analysis in clinical and everyday settings.


  • Open Access

    Respiration parameter determination with non-obstructive methods

    by Sven Fisahn, Christian Siebauer, Jan Ringkamp, Kirsten J. Dehning, Stefan Zimmermann, Jens Langejürgen

    Measuring respiratory parameters like the breathing frequency or the tidal volume is essential in intensive care to ensure an optimal and lung protecting ventilation. A common practice in artificial ventilation of sensitive patients like infants or neonates is the use of uncuffed endotracheal tubes in combination with continuous positive airway pressure (CPAP). This comes with the disadvantage of an unknown leakage making it difficult to detect spontaneous breathing or to measure the tidal volume reliable. A novel non-obstructive method to determine respiratory parameters as well as dynamic changes of thoracic parameters has recently been presented and uses a pair of coupled UHF (ultra high frequency) antennae. In this paper, a respective setup is investigated numerically using finite difference time domain method and experimentally using an artificial lung phantom. Both approaches show that the investigated method seems capable of allowing a contactless triggering to synchronize natural and artificial breathing. The results are compared to derive a better understanding of influencing factors and opportunities for an optimisation.