Beamformer for a Lensed Row–Column Array in 3-D Ultrasound Imaging
- 6 January 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (2) , 238-250
Abstract
Row-column (RC) arrays typically suffer from a limited field of view (FOV), with the imaging area confined to a rectangular region equal to the footprint of the probe. This limitation can be solved by using a diverging lens in front of the probe. Previous studies have introduced a Thin Lens model for beamforming lensed RC arrays, but this model inaccurately assumes the lens to be infinitely thin, leading to degraded resolution and contrast due to errors in the time of flight (TOF) calculations. This paper presents a beamformer based on ray tracing for accurate TOF calculation. A Verasonics Vantage 256 scanner was equipped with a Vermon RC probe with 128 + 128 elements, λ pitch, and a 6 MHz center frequency. A synthetic aperture ultrasound sequence with 96 virtual sources and 32 active elements for each emission with row elements was employed, and all column elements were used for acquiring data. This method was tested with a polystyrene (PS) lens with a spherical shape and polymethyl methacrylate (PMMA) in a Bicylindrical shape. Based on pressure field measurements, these two lenses provide a 20° and 33° FOV, respectively. The Thin Lens model had a lateral resolution of around 17.4λ for the Bicylindrical lens, whereas the new method achieves a resolution of around 3.8λ, representing a 4.6-fold improvement. The contrast is enhanced from 23.1 to 29.8 dB for the Bicylindrical lens while preserving the FOV.Keywords
Funding Information
- European Research Council’s (ERC) Synergy (854796)
This publication has 40 references indexed in Scilit:
- Increasing Penetration Depth and Field-of-view in 3D Ultrasound Imaging with a Lensed Row-column Array2023
- Novel Diverging Acoustic Lens Geometries for Row-Column Array Transducers2023
- Diverging Polymer Lens Design and Fabrication for Row-Column Addressed Transducers2022
- Effect of Acoustic Properties of Lens Materials on Performance of Capacitive Micromachined Ultrasonic TransducersJournal of Medical and Biological Engineering, 2016
- Design of Optimal 2-D Nongrid Sparse Arrays for Medical UltrasoundIEEE Transactions on Biomedical Engineering, 2013
- A new acoustic lens material for large area detectors in photoacoustic breast tomographyPhotoacoustics, 2013
- Negative lens concept for photoacoustic tomographyPhysical Review E, 2008
- Real-time rectilinear volumetric imaging using a periodic arrayUltrasound in Medicine & Biology, 2002
- Broad-bandwidth radiation patterns of sparse two-dimensional vernier arraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Two-Dimensional Random Arrays for Real Time Volumetric ImagingUltrasonic Imaging, 1994