An in vitro comparison of tibial tray cementation using gun pressurization or pulsed lavage
- 12 March 2014
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (5) , 967-971
Abstract
Aseptic loosening of the tibial component remains a limitation to the highly successful procedure of total knee arthroplasty (TKA). Pulsed lavage improves bone cement penetration and interface strength in tibial tray cementation. This study tested whether pressurized cement application with a cement gun can compensate the use of jet lavage for bone surface preparation. Tibial components were implanted in six pairs of cadaveric tibiae. On one side, pulsed lavage of the tibial bone was combined with finger packing of bone cement; on the other side, syringe lavage and gun cementing was used. Cement penetration into the bone was determined from computed tomography scans, and Interface strength was determined by pull-out testing. Cement penetration was greater (p = 0.004) and interface strength was higher (p = 0.028) in the pulsed lavage group. Pressurization of cement by gun application could not compensate for the omission of pulsed lavage. Thus, pulsed lavage should be considered a crucial factor in TKA to improve implant fixation, which cannot be compensated for by cement application technique.Keywords
This publication has 23 references indexed in Scilit:
- Cementing the Tibial Component in Total Knee ArthroplastyThe Journal of Arthroplasty, 2011
- The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacementJournal of Biomechanics, 2011
- Pulsed lavage improves fixation strength of cemented tibial componentsInternational Orthopaedics, 2010
- Survival and clinical function of cemented and uncemented prostheses in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- The Effect of Cement Gun and Cement Syringe Use on the Tibial Cement Mantle in Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Surface Cementation of Stemmed Tibial Components in Primary Total Knee ArthroplastyThe Journal of Arthroplasty, 2006
- The Swedish knee arthroplasty register: A nation-wide study of 30,003 knees 1976-1992Acta Orthopaedica, 1994
- Cemented Total Hip Arthroplasty with Contemporary TechniquesClinical Orthopaedics and Related Research, 1988
- Patellofemoral DisordersClinical Orthopaedics and Related Research, 1984
- Effect of cement pressure and bone strength on polymethylmethacrylate fixationJournal of Orthopaedic Research, 1983