Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming
Open Access
- 26 July 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 194-204
Abstract
Minimum Variance (MV) beamforming is known to improve the lateral resolution of ultrasound images and enhance the separation of isolated point scatterers. This paper aims to evaluate the adaptive beamformer's performance with flowing microbubbles (MBs) which are relevant to super-resolution ultrasound imaging. Simulations using point scatterer data from single emissions were complemented by an experimental investigation performed using a capillary tube phantom and the Synthetic Aperture Real-time Ultrasound System (SARUS). The MV performance was assessed by the minimum distance that allows the display of two scatterers positioned side-by-side, the lateral Full-Width-at-Half-Maximum (FWHM), and the Peak-Sidelobe-Level (PSL). In the tube, scatterer responses separated by down to 196 μm (or 1.05λ) were distinguished by the MV method, while the standard Delay-And-Sum (DAS) beamformers were unable to achieve such separation. Up to ninefold FWHM decrease was also measured in favor of the MV beamformer for individual echoes from MBs. The lateral distance between two scatterers impacted on their FWHM value, and additional differences in the scatterers' axial or out-of-plane position also impacted on their size and appearance. The simulation and experimental results were in agreement in terms of lateral resolution. The point scatterer study showed that the proposed MV imaging scheme provided clear resolution benefits compared to DAS. Current super-resolution methods mainly depend on DAS beamformers. Instead, the use of the MV method may provide a larger number of detected, and potentially better localized, MB scatterers.Keywords
Funding Information
- Science and Technology Facilities Council (STFC-ST/M007804/1)
- Danish Advanced Technology Foundation (82-2012-4)
- B-K Ultrasound ApS
This publication has 37 references indexed in Scilit:
- GPU-Based Minimum Variance Beamformer for Synthetic Aperture Imaging of the EyeUltrasound in Medicine & Biology, 2015
- In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using MicrobubblesIEEE Transactions on Medical Imaging, 2014
- Capon beamforming and moving objects-an analysis of lateral shift-invarianceIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Three-Dimensional Transcranial Ultrasound Imaging of Microbubble Clouds Using a Sparse Hemispherical ArrayIEEE Transactions on Biomedical Engineering, 2014
- Ultrafast imaging in biomedical ultrasoundIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Implementing capon beamforming on a GPU for real-time cardiac ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- SARUS: A synthetic aperture real-time ultrasound systemIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Detection of Individual Microbubbles of Ultrasound Contrast AgentsInvestigative Radiology, 2004
- Anin vitrostudy of a microbubble contrast agent using a clinical ultrasound imaging systemPhysics in Medicine & Biology, 2003
- Water as a standard in the measurements of speed of sound in liquidsThe Journal of the Acoustical Society of America, 1997