This paper presents a low-noise bioimpedance (bio-Z) spectroscopy interface for electrical impedance myography (EIM) over the 1 kHz to 2 MHz frequency range. The proposed interface employs a sinusoidal signal generator based on direct-digital-synthesis (DDS) to improve the accuracy of the bio-Z reading, and a quadrature low-intermediate frequency (IF) readout to achieve a good noise-to-power efficiency and the required data throughput to detect muscle contractions. The readout is able to measure baseline and time-varying bio-Z by employing robust and power-efficient low-gain IAs and sixth-order single-bit bandpass (BP) ΔΣ ADCs. The proposed bio-Z spectroscopy interface is implemented in a 180 nm CMOS process, consumes 344.3 - 479.3 μ W, and occupies 5.4 mm 2 area. Measurement results show 0.7 $\rm {m} \Omega/\sqrt{Hz}$ sensitivity at 15.625 kHz, 105.8 dB SNR within 4 Hz bandwidth, and a 146.5 dB figure-of-merit. Additionally, recording of EIM in time and frequency domain during contractions of the bicep brachii muscle demonstrates the potential of the proposed bio-Z interface for wearable EIM systems.Keywords
Funding Information
- Swedish Foundation for Strategic Research (ITM17-0079)
This publication has 34 references indexed in Scilit:
- A battery-less implantable glucose sensor based on electrical impedance spectroscopyScientific Reports, 2023
- A Low-Distortion Current-Mode Signal Generator for Wide-Range Bioimpedance Spectroscopy2023
- Multi-Frequency Impedance Myography: The PhaseX EffectIEEE Sensors Journal, 2020
- Combining Bioimpedance and EMG Measurements for Reliable Muscle Contraction DetectionIEEE Sensors Journal, 2019
- Present Uses, Future Applications, and Technical Underpinnings of Electrical Impedance MyographyCurrent Neurology and Neuroscience Reports, 2017
- Electrical impedance myography for assessment of Duchenne muscular dystrophyAnnals of Neurology, 2017
- Electrical Impedance Myography and Its Applications in Neuromuscular DisordersNeurotherapeutics, 2017
- Influence of advanced electromyogram (EMG) amplitude processors on EMG-to-torque estimation during constant-posture, force-varying contractionsJournal of Biomechanics, 2006
- Multibit bandpass delta-sigma modulators using N-path structures2003
- Quadrature bandpass ΔΣ modulation for digital radioIEEE Journal of Solid-State Circuits, 1997