Pedicle screw accuracy assessment in ExcelsiusGPS® robotic spine surgery: evaluation of deviation from pre-planned trajectory
Authors:
- Bowen JiangBJBowen Jiang
- A. Karim AhmedAAA. Karim Ahmed
- Corinna C. ZygourakisCZCorinna C. Zygourakis
- Samuel KalbSKSamuel Kalb
- Alex M. ZhuAZAlex M. Zhu
- Jakub GodzikJGJakub Godzik
- Camilo A. MolinaCMCamilo A. Molina
- Ari M. BlitzABAri M. Blitz
- Ali BydonABAli Bydon
- Neil CrawfordNCNeil Crawford
- Nicholas TheodoreNTNicholas Theodore
Open Access
- 3 September 2018
- journal article
- research article
- Published by Springer Nature in Chinese Neurosurgical Journal
- Vol. 4 (1) , 1-6
Abstract
The ExcelsiusGPS® (Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS® robotic system and describe a novel metric to quantify screw deviation. Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS® surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8–5.2 mm), mean tail deviation was 3.2 mm (range 0.9–5.4 mm), and mean angular offset was 2.4 degrees (range 0.7–3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. The ExcelsiusGPS® robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.Keywords
This publication has 23 references indexed in Scilit:
- Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgeryNeurosurgical Focus, 2017
- Current applications of robotics in spine surgery: a systematic review of the literatureNeurosurgical Focus, 2017
- Navigation and Robotics in Spinal Surgery: Where Are We Now?Neurosurgery, 2017
- Evaluation of the ROSA™ Spine robot for minimally invasive surgical proceduresExpert Review of Medical Devices, 2016
- A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placementsMedicine, 2016
- Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic reviewEuropean Spine Journal, 2013
- A review of surgical robots for spinal interventionsThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT AnalysisSpine, 2005
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990