Bowen Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bowen Jiang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Alexander L. Coon
Carondelet Neurosurgical Institute of St. Joseph's Hospital, Tucson, Arizona, USA
4 shared publications - Geoffrey P. Colby
Department of Neurosurgery, University of California, Los Angeles, Los Angeles, USA
4 shared publications - Judy Huang
Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD, United States
3 shared publications - Li-Mei Lin
Carondelet Neurological Institute, St Joseph's Hospital, Carondelet Health Network, Tucson, Arizona, USA
3 shared publications - Corinna C. Zygourakis
Johns Hopkins University, Department of Neurosurgery, Baltimore, MD
2 shared publications - Nicholas Theodore
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
2 shared publications
Latest Publications
- 13 May 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (03) , 035001-16
Automatic analysis of global spinal alignment from simple annotation of vertebral bodies
Purpose: Measurement of global spinal alignment (GSA) is an important aspect of diagnosis and treatment evaluation for spinal deformity but is subject to a high level of inter-reader variability. Approach: Two methods for automatic GSA measurement are proposed to mitigate such variability and reduce the burden of manual measurements. Both approaches use vertebral labels in spine computed tomography (CT) as input: the first (EndSeg) segments vertebral endplates using input labels as seed points; and the second (SpNorm) computes a two-dimensional curvilinear fit to the input labels. Studies were performed to characterize the performance of EndSeg and SpNorm in comparison to manual GSA measurement by five clinicians, including measurements of proximal thoracic kyphosis, main thoracic kyphosis, and lumbar lordosis. Results: For the automatic methods, 93.8% of endplate angle estimates were within the inter-reader 95% confidence interval (CI95). All GSA measurements for the automatic methods were within the inter-reader CI95, and there was no statistically significant difference between automatic and manual methods. The SpNorm method appears particularly robust as it operates without segmentation. Conclusions: Such methods could improve the reproducibility and reliability of GSA measurements and are potentially suitable to applications in large datasets—e.g., for outcome assessment in surgical data science.
- 13 May 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (03) , 035001-16
Automatic analysis of global spinal alignment from simple annotation of vertebral bodies
Purpose: Measurement of global spinal alignment (GSA) is an important aspect of diagnosis and treatment evaluation for spinal deformity but is subject to a high level of inter-reader variability. Approach: Two methods for automatic GSA measurement are proposed to mitigate such variability and reduce the burden of manual measurements. Both approaches use vertebral labels in spine computed tomography (CT) as input: the first (EndSeg) segments vertebral endplates using input labels as seed points; and the second (SpNorm) computes a two-dimensional curvilinear fit to the input labels. Studies were performed to characterize the performance of EndSeg and SpNorm in comparison to manual GSA measurement by five clinicians, including measurements of proximal thoracic kyphosis, main thoracic kyphosis, and lumbar lordosis. Results: For the automatic methods, 93.8% of endplate angle estimates were within the inter-reader 95% confidence interval (CI95). All GSA measurements for the automatic methods were within the inter-reader CI95, and there was no statistically significant difference between automatic and manual methods. The SpNorm method appears particularly robust as it operates without segmentation. Conclusions: Such methods could improve the reproducibility and reliability of GSA measurements and are potentially suitable to applications in large datasets—e.g., for outcome assessment in surgical data science.
- Open Access
- 3 September 2018
- Published by Springer Nature in Chinese Neurosurgical Journal
- Vol. 4 (1) , 1-6
Pedicle screw accuracy assessment in ExcelsiusGPS® robotic spine surgery: evaluation of deviation from pre-planned trajectory
The ExcelsiusGPS® (Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS® robotic system and describe a novel metric to quantify screw deviation. Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS® surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8–5.2 mm), mean tail deviation was 3.2 mm (range 0.9–5.4 mm), and mean angular offset was 2.4 degrees (range 0.7–3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. The ExcelsiusGPS® robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.
- 3 September 2018
- Published by Springer Nature in Chinese Neurosurgical Journal
- Vol. 4 (1) , 1-6
Open AccessPedicle screw accuracy assessment in ExcelsiusGPS® robotic spine surgery: evaluation of deviation from pre-planned trajectory
The ExcelsiusGPS® (Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS® robotic system and describe a novel metric to quantify screw deviation. Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS® surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8–5.2 mm), mean tail deviation was 3.2 mm (range 0.9–5.4 mm), and mean angular offset was 2.4 degrees (range 0.7–3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. The ExcelsiusGPS® robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.
- Open Access
- 1 June 2017
- Published by Elsevier in Interdisciplinary Neurosurgery
- Vol. 8, 35-39
Chronic anticoagulation with warfarin is associated with decreased functional outcome and increased length of stay following craniotomy for acute subdural hematoma
- 1 June 2017
- Published by Elsevier in Interdisciplinary Neurosurgery
- Vol. 8, 35-39
Open AccessChronic anticoagulation with warfarin is associated with decreased functional outcome and increased length of stay following craniotomy for acute subdural hematoma
- Open Access
- 1 January 2017
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 8 (1) , 154
Aneurysm treatment practice patterns for newly appointed dual-trained cerebrovascular/endovascular neurosurgeons: Comparison of open surgical to neuroendovascular procedures in the first 2 years of academic practice
The practice patterns of a hybrid open cerebrovascular/neuroendovascular (CVNV) neurosurgeon in early academic practice is unknown. We performed a multi-institutional retrospective cohort study of patients with cerebral aneurysms that were treated within the first 24 months of the neurosurgeon's practice. A total of 533 aneurysms were treated by the three senior authors within the first 24 months of their academic practice. Of these aneurysms, 172 were treated with microsurgical clipping, 191 with coiling, and 170 with flow diversion. Treatment in the setting of acute subarachnoid hemorrhage (SAH) occurred in 23% (122/533) of the aneurysms. Majority of the clipped aneurysms (70%, 121/172) were anterior cerebral artery (ACA), anterior communicating artery (ACOM), or middle cerebral artery (MCA) in location. In comparison, only 23% (82/361) of aneurysms treated with coiling or flow diversion therapy were ACA, ACOM, or MCA in location (P < 0.05). Additionally, majority of the flow diverted aneurysm (65%, 111/170) were cavernous or ophthalmic/paraophthalmic in location. During the second year of practice, there appeared to be a trend towards more aneurysms treated with neuroendovascular techniques (22% increase), particularly in flow diversion. Although the CVNV neurosurgeon treats cerebral aneurysms more commonly with neuroendovascular techniques, a third of the cerebral aneurysms are still selected for microsurgical clipping. Aneurysms located along the ACA/ACOM or MCA are the most frequent aneurysms reserved for microsurgical clipping. The CVNV neurosurgeon must be prepared to manage a high percentage of ACA/ACOM or MCA aneurysms microsurgically.
- 1 January 2017
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 8 (1) , 154
Open AccessAneurysm treatment practice patterns for newly appointed dual-trained cerebrovascular/endovascular neurosurgeons: Comparison of open surgical to neuroendovascular procedures in the first 2 years of academic practice
The practice patterns of a hybrid open cerebrovascular/neuroendovascular (CVNV) neurosurgeon in early academic practice is unknown. We performed a multi-institutional retrospective cohort study of patients with cerebral aneurysms that were treated within the first 24 months of the neurosurgeon's practice. A total of 533 aneurysms were treated by the three senior authors within the first 24 months of their academic practice. Of these aneurysms, 172 were treated with microsurgical clipping, 191 with coiling, and 170 with flow diversion. Treatment in the setting of acute subarachnoid hemorrhage (SAH) occurred in 23% (122/533) of the aneurysms. Majority of the clipped aneurysms (70%, 121/172) were anterior cerebral artery (ACA), anterior communicating artery (ACOM), or middle cerebral artery (MCA) in location. In comparison, only 23% (82/361) of aneurysms treated with coiling or flow diversion therapy were ACA, ACOM, or MCA in location (P < 0.05). Additionally, majority of the flow diverted aneurysm (65%, 111/170) were cavernous or ophthalmic/paraophthalmic in location. During the second year of practice, there appeared to be a trend towards more aneurysms treated with neuroendovascular techniques (22% increase), particularly in flow diversion. Although the CVNV neurosurgeon treats cerebral aneurysms more commonly with neuroendovascular techniques, a third of the cerebral aneurysms are still selected for microsurgical clipping. Aneurysms located along the ACA/ACOM or MCA are the most frequent aneurysms reserved for microsurgical clipping. The CVNV neurosurgeon must be prepared to manage a high percentage of ACA/ACOM or MCA aneurysms microsurgically.
- 1 September 2016
- Published by Elsevier in World Neurosurgery
- Vol. 93, 11-18
Is Carotid Revascularization Safe for Patients with Concomitant Carotid Stenosis and Intracranial Aneurysms?
- 1 September 2016
- Published by Elsevier in World Neurosurgery
- Vol. 93, 11-18
Is Carotid Revascularization Safe for Patients with Concomitant Carotid Stenosis and Intracranial Aneurysms?
- Open Access
- 14 June 2016
- Published by Elsevier in Interdisciplinary Neurosurgery
- Vol. 6, 29-34
Pentaxial access platform for ultra-distal intracranial delivery of a large-bore hyperflexible DIC (distal intracranial catheter): A technical note
- 14 June 2016
- Published by Elsevier in Interdisciplinary Neurosurgery
- Vol. 6, 29-34
Open AccessPentaxial access platform for ultra-distal intracranial delivery of a large-bore hyperflexible DIC (distal intracranial catheter): A technical note