Corinna C. Zygourakis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Corinna C. Zygourakis has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
A. Karim Ahmed
Department of Neurological Surgery, Johns Hopkins Hospital, Baltimore, Maryland, USA
2 shared publications- Bowen Jiang
Johns Hopkins University, Department of Neurosurgery, Baltimore, MD
2 shared publications - Nicholas Theodore
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
2 shared publications - A. Karim Ahmed
Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
1 shared publication - Alex M. Zhu
Department of Neurosurgery, The Johns Hopkins School of Medicine, The Johns Hopkins Hospital, 600 N. Wolfe Street, Meyer 7-113, Baltimore, MD, 21287, USA
1 shared publication Alex Zhu
Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, MD, United States
1 shared publication
Latest Publications
- 13 May 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (03) , 035001-16
Automatic analysis of global spinal alignment from simple annotation of vertebral bodies
Purpose: Measurement of global spinal alignment (GSA) is an important aspect of diagnosis and treatment evaluation for spinal deformity but is subject to a high level of inter-reader variability. Approach: Two methods for automatic GSA measurement are proposed to mitigate such variability and reduce the burden of manual measurements. Both approaches use vertebral labels in spine computed tomography (CT) as input: the first (EndSeg) segments vertebral endplates using input labels as seed points; and the second (SpNorm) computes a two-dimensional curvilinear fit to the input labels. Studies were performed to characterize the performance of EndSeg and SpNorm in comparison to manual GSA measurement by five clinicians, including measurements of proximal thoracic kyphosis, main thoracic kyphosis, and lumbar lordosis. Results: For the automatic methods, 93.8% of endplate angle estimates were within the inter-reader 95% confidence interval (CI95). All GSA measurements for the automatic methods were within the inter-reader CI95, and there was no statistically significant difference between automatic and manual methods. The SpNorm method appears particularly robust as it operates without segmentation. Conclusions: Such methods could improve the reproducibility and reliability of GSA measurements and are potentially suitable to applications in large datasets—e.g., for outcome assessment in surgical data science.
- 13 May 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (03) , 035001-16
Automatic analysis of global spinal alignment from simple annotation of vertebral bodies
Purpose: Measurement of global spinal alignment (GSA) is an important aspect of diagnosis and treatment evaluation for spinal deformity but is subject to a high level of inter-reader variability. Approach: Two methods for automatic GSA measurement are proposed to mitigate such variability and reduce the burden of manual measurements. Both approaches use vertebral labels in spine computed tomography (CT) as input: the first (EndSeg) segments vertebral endplates using input labels as seed points; and the second (SpNorm) computes a two-dimensional curvilinear fit to the input labels. Studies were performed to characterize the performance of EndSeg and SpNorm in comparison to manual GSA measurement by five clinicians, including measurements of proximal thoracic kyphosis, main thoracic kyphosis, and lumbar lordosis. Results: For the automatic methods, 93.8% of endplate angle estimates were within the inter-reader 95% confidence interval (CI95). All GSA measurements for the automatic methods were within the inter-reader CI95, and there was no statistically significant difference between automatic and manual methods. The SpNorm method appears particularly robust as it operates without segmentation. Conclusions: Such methods could improve the reproducibility and reliability of GSA measurements and are potentially suitable to applications in large datasets—e.g., for outcome assessment in surgical data science.
- 13 December 2018
- Published by Springer Nature
- p. 69-73
Posterolateral Thoracotomy
- Open Access
- 3 September 2018
- Published by Springer Nature in Chinese Neurosurgical Journal
- Vol. 4 (1) , 1-6
Pedicle screw accuracy assessment in ExcelsiusGPS® robotic spine surgery: evaluation of deviation from pre-planned trajectory
The ExcelsiusGPS® (Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS® robotic system and describe a novel metric to quantify screw deviation. Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS® surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8–5.2 mm), mean tail deviation was 3.2 mm (range 0.9–5.4 mm), and mean angular offset was 2.4 degrees (range 0.7–3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. The ExcelsiusGPS® robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.
- 3 September 2018
- Published by Springer Nature in Chinese Neurosurgical Journal
- Vol. 4 (1) , 1-6
Open AccessPedicle screw accuracy assessment in ExcelsiusGPS® robotic spine surgery: evaluation of deviation from pre-planned trajectory
The ExcelsiusGPS® (Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS® robotic system and describe a novel metric to quantify screw deviation. Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS® surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8–5.2 mm), mean tail deviation was 3.2 mm (range 0.9–5.4 mm), and mean angular offset was 2.4 degrees (range 0.7–3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. The ExcelsiusGPS® robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology.
- 1 August 2018
- Published by Elsevier in World Neurosurgery
- Vol. 116, e944-e950
The Safety and Efficacy of CT-Guided, Fluoroscopy-Free Vertebroplasty in Adult Spinal Deformity Surgery
- 1 August 2018
- Published by Elsevier in World Neurosurgery
- Vol. 116, e944-e950
The Safety and Efficacy of CT-Guided, Fluoroscopy-Free Vertebroplasty in Adult Spinal Deformity Surgery
- 1 July 2018
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 53, 235-237
Immediate improvement of intraoperative monitoring signals following CSF release for cervical spine stenosis: Case report
- 1 July 2018
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 53, 235-237
Immediate improvement of intraoperative monitoring signals following CSF release for cervical spine stenosis: Case report