Abstract
In this study, yellow nitrazine immobilized on a polymer matrix was used as an analytical reagent for the determination of Ni(II), with PPA fiber used as the carrier. The purpose of using the sorbent is to determine and separate low concentrations of Ni(II) ions in various water samples. The advantage of this method over others lies in the use of inexpensive synthetic carrier fibers as the matrix, as well as the improved metrological analytical parameters for detection. The complex formed with immobilized yellow nitrazine provides an analytical signal at a wavelength of 550 nm, with the optimal reaction pH determined to be in the range of 6.0-6.5. According to the Beer-Lambert-Bouguer law, a linear relationship was observed in the concentration range of 0.2-2.0 𝜇g/mL. The sensitivity based on Sandell's criterion was found to be 0.0016 𝜇g/cm 2. To evaluate the accuracy of the method, results were compared using t-test and F-test table values (t exp = 3.58; t crit = 4.60, F exp = 9.79; F crit = 10.97). Under the selected conditions, common interfering ions present in water samples were found not to affect the determination of nickel ions. The proposed method is simple, cost-effective, rapid, sensitive, accurate, and highly selective.