Utkir Madatov
Research Subjects
Utkir Madatov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Bakhtiyor Rasulev
1 shared publication- Bektosh Normatov1 shared publication
- Dilbar Shakhidova1 shared publication
- Feruzakhon Tojiboyeva
Department of Analytical Chemistry, National University of Uzbekistan named after Mirzo Ulugbek, Tashkent 100174, Uzbekistan
1 shared publication - Khonzoda Turayeva
Karshi State University
1 shared publication - Samariddin Rakhimov
Department of Analytical Chemistry, National University of Uzbekistan, Tashkent, Uzbekistan
1 shared publication
Latest Publications
- Open Access
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Sorption-Spectrophotometric Determination of Ni(II) Ions in Aqueous Samples Based on the Immobilization of Nitrazine Reagent on a Polymer Fiber
In this study, yellow nitrazine immobilized on a polymer matrix was used as an analytical reagent for the determination of Ni(II), with PPA fiber used as the carrier. The purpose of using the sorbent is to determine and separate low concentrations of Ni(II) ions in various water samples. The advantage of this method over others lies in the use of inexpensive synthetic carrier fibers as the matrix, as well as the improved metrological analytical parameters for detection. The complex formed with immobilized yellow nitrazine provides an analytical signal at a wavelength of 550 nm, with the optimal reaction pH determined to be in the range of 6.0-6.5. According to the Beer-Lambert-Bouguer law, a linear relationship was observed in the concentration range of 0.2-2.0 𝜇g/mL. The sensitivity based on Sandell's criterion was found to be 0.0016 𝜇g/cm 2. To evaluate the accuracy of the method, results were compared using t-test and F-test table values (t exp = 3.58; t crit = 4.60, F exp = 9.79; F crit = 10.97). Under the selected conditions, common interfering ions present in water samples were found not to affect the determination of nickel ions. The proposed method is simple, cost-effective, rapid, sensitive, accurate, and highly selective.
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSorption-Spectrophotometric Determination of Ni(II) Ions in Aqueous Samples Based on the Immobilization of Nitrazine Reagent on a Polymer Fiber
In this study, yellow nitrazine immobilized on a polymer matrix was used as an analytical reagent for the determination of Ni(II), with PPA fiber used as the carrier. The purpose of using the sorbent is to determine and separate low concentrations of Ni(II) ions in various water samples. The advantage of this method over others lies in the use of inexpensive synthetic carrier fibers as the matrix, as well as the improved metrological analytical parameters for detection. The complex formed with immobilized yellow nitrazine provides an analytical signal at a wavelength of 550 nm, with the optimal reaction pH determined to be in the range of 6.0-6.5. According to the Beer-Lambert-Bouguer law, a linear relationship was observed in the concentration range of 0.2-2.0 𝜇g/mL. The sensitivity based on Sandell's criterion was found to be 0.0016 𝜇g/cm 2. To evaluate the accuracy of the method, results were compared using t-test and F-test table values (t exp = 3.58; t crit = 4.60, F exp = 9.79; F crit = 10.97). Under the selected conditions, common interfering ions present in water samples were found not to affect the determination of nickel ions. The proposed method is simple, cost-effective, rapid, sensitive, accurate, and highly selective.