Feruzakhon Tojiboyeva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feruzakhon Tojiboyeva has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Enrico Benassi
Infochemistry Scientific Center, ITMO University, Saint-Petersburg 191002, Russian Federation
3 shared publications - Nazira Madusmanova
Almalyk State Technical University
3 shared publications - Zulayho Smanova
Department of Analytical Chemistry, Faculty of Chemistry, National University of Uzbekistan, Tashkent 100174, Uzbekistan
3 shared publications - Ayjamal Turambetova2 shared publications
- Dilrabo Muhammadiyeva2 shared publications
- Go`zAl Yunusova2 shared publications
Latest Publications
- 16 July 2026
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 363 (Pt 2) , 128464
Sorption–spectroscopic determination of chromium (III) ions using eriochrome black T immobilized on silk fibroin fiber
- 16 July 2026
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 363 (Pt 2) , 128464
Sorption–spectroscopic determination of chromium (III) ions using eriochrome black T immobilized on silk fibroin fiber
- Open Access
- 18 April 2026
- Published by Elsevier in SSRN Electronic Journal
Sorption–Spectroscopic Determination of Chromium (III) Ions Using Eriochrome Black T Immobilized on Silk Fibroin Fiber
Background:Chromium (III) ions are widely present in industrial and environmental waters, and their reliable determination is essential for environmental monitoring and pollution control. Conventional spectrophotometric methods often suffer from limited sensitivity, selectivity, and stability. To overcome these limitations, a sorption–spectrophotometric approach based on reagent immobilization was developed. In this study, Eriochrome Black T (EBT) was immobilized on silk fibroin fiber to enhance analytical performance in the determination of Cr(III) ions.Results:Immobilization of EBT significantly improved the stability, sensitivity, and selectivity of the method. Formation of the Cr(III)–EBT complex was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis, and SEM-EDS, which indicated approximately 20 wt % chromium in the complex. Optimal analytical conditions were pH 8, λ = 618 nm, and a universal buffer. The method showed a detection limit of 1.2 µg L⁻¹, linearity in the range of 5–50 µg L⁻¹ (R² = 0.9991), and an analysis time of 10 min. Interference from Al³⁺, Co²⁺, and Cd²⁺ was effectively masked, while Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference. Validation using industrial wastewater samples demonstrated relative errors ≤ 6 % and Sr ≤ 0.085.Significance:The developed sorption–spectrophotometric method provides a rapid, economical, and accurate approach for the determination of Cr(III) ions in environmental waters. Its high sensitivity, good selectivity, and successful application to real industrial wastewater samples indicate strong potential for routine laboratory analysis as well as field monitoring of chromium contamination.
- 18 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSorption–Spectroscopic Determination of Chromium (III) Ions Using Eriochrome Black T Immobilized on Silk Fibroin Fiber
Background:Chromium (III) ions are widely present in industrial and environmental waters, and their reliable determination is essential for environmental monitoring and pollution control. Conventional spectrophotometric methods often suffer from limited sensitivity, selectivity, and stability. To overcome these limitations, a sorption–spectrophotometric approach based on reagent immobilization was developed. In this study, Eriochrome Black T (EBT) was immobilized on silk fibroin fiber to enhance analytical performance in the determination of Cr(III) ions.Results:Immobilization of EBT significantly improved the stability, sensitivity, and selectivity of the method. Formation of the Cr(III)–EBT complex was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis, and SEM-EDS, which indicated approximately 20 wt % chromium in the complex. Optimal analytical conditions were pH 8, λ = 618 nm, and a universal buffer. The method showed a detection limit of 1.2 µg L⁻¹, linearity in the range of 5–50 µg L⁻¹ (R² = 0.9991), and an analysis time of 10 min. Interference from Al³⁺, Co²⁺, and Cd²⁺ was effectively masked, while Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference. Validation using industrial wastewater samples demonstrated relative errors ≤ 6 % and Sr ≤ 0.085.Significance:The developed sorption–spectrophotometric method provides a rapid, economical, and accurate approach for the determination of Cr(III) ions in environmental waters. Its high sensitivity, good selectivity, and successful application to real industrial wastewater samples indicate strong potential for routine laboratory analysis as well as field monitoring of chromium contamination.
- Open Access
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Sorption-Spectrophotometric Determination of Ni(II) Ions in Aqueous Samples Based on the Immobilization of Nitrazine Reagent on a Polymer Fiber
In this study, yellow nitrazine immobilized on a polymer matrix was used as an analytical reagent for the determination of Ni(II), with PPA fiber used as the carrier. The purpose of using the sorbent is to determine and separate low concentrations of Ni(II) ions in various water samples. The advantage of this method over others lies in the use of inexpensive synthetic carrier fibers as the matrix, as well as the improved metrological analytical parameters for detection. The complex formed with immobilized yellow nitrazine provides an analytical signal at a wavelength of 550 nm, with the optimal reaction pH determined to be in the range of 6.0-6.5. According to the Beer-Lambert-Bouguer law, a linear relationship was observed in the concentration range of 0.2-2.0 𝜇g/mL. The sensitivity based on Sandell's criterion was found to be 0.0016 𝜇g/cm 2. To evaluate the accuracy of the method, results were compared using t-test and F-test table values (t exp = 3.58; t crit = 4.60, F exp = 9.79; F crit = 10.97). Under the selected conditions, common interfering ions present in water samples were found not to affect the determination of nickel ions. The proposed method is simple, cost-effective, rapid, sensitive, accurate, and highly selective.
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSorption-Spectrophotometric Determination of Ni(II) Ions in Aqueous Samples Based on the Immobilization of Nitrazine Reagent on a Polymer Fiber
In this study, yellow nitrazine immobilized on a polymer matrix was used as an analytical reagent for the determination of Ni(II), with PPA fiber used as the carrier. The purpose of using the sorbent is to determine and separate low concentrations of Ni(II) ions in various water samples. The advantage of this method over others lies in the use of inexpensive synthetic carrier fibers as the matrix, as well as the improved metrological analytical parameters for detection. The complex formed with immobilized yellow nitrazine provides an analytical signal at a wavelength of 550 nm, with the optimal reaction pH determined to be in the range of 6.0-6.5. According to the Beer-Lambert-Bouguer law, a linear relationship was observed in the concentration range of 0.2-2.0 𝜇g/mL. The sensitivity based on Sandell's criterion was found to be 0.0016 𝜇g/cm 2. To evaluate the accuracy of the method, results were compared using t-test and F-test table values (t exp = 3.58; t crit = 4.60, F exp = 9.79; F crit = 10.97). Under the selected conditions, common interfering ions present in water samples were found not to affect the determination of nickel ions. The proposed method is simple, cost-effective, rapid, sensitive, accurate, and highly selective.
- Open Access
- 7 March 2026
- Published by Elsevier in SSRN Electronic Journal
Sorption–Spectroscopic Determination of Chromium (III) Ions Using Eriochrome Black T Immobilized on Silk Fibroin Fiber
Background:Chromium (III) ions are widely present in industrial and environmental waters, and their reliable determination is essential for environmental monitoring and pollution control. Conventional spectrophotometric methods often suffer from limited sensitivity, selectivity, and stability. To overcome these limitations, a sorption–spectrophotometric approach based on reagent immobilization was developed. In this study, Eriochrome Black T (EBT) was immobilized on silk fibroin fiber to enhance analytical performance in the determination of Cr(III) ions. Results:Immobilization of EBT significantly improved the stability, sensitivity, and selectivity of the method. Formation of the Cr(III)–EBT complex was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis, and SEM-EDS, which indicated approximately 20 wt % chromium in the complex. Optimal analytical conditions were pH 8, λ = 618 nm, and a universal buffer. The method showed a detection limit of 1.2 µg L⁻¹, linearity in the range of 5–50 µg L⁻¹ (R² = 0.9991), and an analysis time of 10 min. Interference from Al³⁺, Co²⁺, and Cd²⁺ was effectively masked, while Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference. Validation using industrial wastewater samples demonstrated relative errors ≤ 6 % and Sr ≤ 0.085. Significance:The developed sorption–spectrophotometric method provides a rapid, economical, and accurate approach for the determination of Cr(III) ions in environmental waters. Its high sensitivity, good selectivity, and successful application to real industrial wastewater samples indicate strong potential for routine laboratory analysis as well as field monitoring of chromium contamination.
- 7 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSorption–Spectroscopic Determination of Chromium (III) Ions Using Eriochrome Black T Immobilized on Silk Fibroin Fiber
Background:Chromium (III) ions are widely present in industrial and environmental waters, and their reliable determination is essential for environmental monitoring and pollution control. Conventional spectrophotometric methods often suffer from limited sensitivity, selectivity, and stability. To overcome these limitations, a sorption–spectrophotometric approach based on reagent immobilization was developed. In this study, Eriochrome Black T (EBT) was immobilized on silk fibroin fiber to enhance analytical performance in the determination of Cr(III) ions. Results:Immobilization of EBT significantly improved the stability, sensitivity, and selectivity of the method. Formation of the Cr(III)–EBT complex was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis, and SEM-EDS, which indicated approximately 20 wt % chromium in the complex. Optimal analytical conditions were pH 8, λ = 618 nm, and a universal buffer. The method showed a detection limit of 1.2 µg L⁻¹, linearity in the range of 5–50 µg L⁻¹ (R² = 0.9991), and an analysis time of 10 min. Interference from Al³⁺, Co²⁺, and Cd²⁺ was effectively masked, while Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference. Validation using industrial wastewater samples demonstrated relative errors ≤ 6 % and Sr ≤ 0.085. Significance:The developed sorption–spectrophotometric method provides a rapid, economical, and accurate approach for the determination of Cr(III) ions in environmental waters. Its high sensitivity, good selectivity, and successful application to real industrial wastewater samples indicate strong potential for routine laboratory analysis as well as field monitoring of chromium contamination.
- Open Access
- 16 January 2026
- Published by Springer Nature in Research Square
Features of sulfur in the nutrition of artichoke plants
It is known that an increase in the dose of nitrogen without sulfur applied to the soil leads to an increase in the content of non-protein substances and sulfur in plant tissues, resulting in sulfur starvation. Also, it must be emphasized that an abundant supply of sulfur also inhibits the flow of physiological and biochemical processes in the plant body. It should be noted that the irrigated soils of the Republic of Uzbekistan are deficient in sulfur, mainly due to changes in the range and reduction of sulfur-containing mineral fertilizers. In addition, the dynamics of sulfur content on irrigated oasis soils of this Republic and its effect on plants have remained virtually unexplored. In this article, the authors studied the effect of sulfur in the organs of the prickly artichoke depending on the level of sulfur nutrition and soil conditions in the regions of Uzbekistan. Researchers have studied the content and productivity of sulfur in various organs of the prickly artichoke and the influence of this nutrient in the absorption and consumption of nitrogen by this plant. Also, determining the optimal ratios of nitrogen to sulfur and, as a final result, developing a cultivation technology that will help reduce the content of nitrates in tissues and increase the production of environmentally friendly products by this crop in various soil conditions.
- 16 January 2026
- Published by Springer Nature in Research Square
Open AccessFeatures of sulfur in the nutrition of artichoke plants
It is known that an increase in the dose of nitrogen without sulfur applied to the soil leads to an increase in the content of non-protein substances and sulfur in plant tissues, resulting in sulfur starvation. Also, it must be emphasized that an abundant supply of sulfur also inhibits the flow of physiological and biochemical processes in the plant body. It should be noted that the irrigated soils of the Republic of Uzbekistan are deficient in sulfur, mainly due to changes in the range and reduction of sulfur-containing mineral fertilizers. In addition, the dynamics of sulfur content on irrigated oasis soils of this Republic and its effect on plants have remained virtually unexplored. In this article, the authors studied the effect of sulfur in the organs of the prickly artichoke depending on the level of sulfur nutrition and soil conditions in the regions of Uzbekistan. Researchers have studied the content and productivity of sulfur in various organs of the prickly artichoke and the influence of this nutrient in the absorption and consumption of nitrogen by this plant. Also, determining the optimal ratios of nitrogen to sulfur and, as a final result, developing a cultivation technology that will help reduce the content of nitrates in tissues and increase the production of environmentally friendly products by this crop in various soil conditions.
- Open Access
- 8 January 2026
- Published by Springer Nature in Research Square
Sorption–spectroscopic Determination of Chromium (Iii) Ions Using Eriochrome Black T Immobilized on Silk Fibroin Fiber
A sorption–spectrophotometric method for the determination of chromium (III) ions was developed using Eriochrome Black T (EBT) immobilized on silk fibroin fiber. Immobilization markedly enhanced the method’s stability, sensitivity, and selectivity. Complex formation was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis (clear Cr peak), and SEM-EDS (≈ 20 wt % Cr in the complex). Optimal conditions were pH 8, λ = 618 nm, and a universal buffer. The detection limit was 1.2 µg L⁻¹; analysis time, 10 min; calibration linearity, R² = 0.9991 for 5–50 µg Cr(III). Average absorbance at 50 µg was 0.273, and Sandell sensitivity 0.00279 µg cm⁻². Selectivity testing showed that Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference, whereas Al³⁺, Co²⁺, and Cd²⁺ interferences were masked effectively. Validation with industrial wastewater (Navoi Electrochemical Plant, Mubarek Gas Processing Plant, Almalyk Mining and Metallurgical Complex) gave relative errors ≤ 6% and Sr ≤ 0.085. The method therefore offers an economical, rapid, and accurate tool for monitoring Cr(III) ions in environmental waters, suitable for both field and laboratory applications.
- 8 January 2026
- Published by Springer Nature in Research Square
Open AccessSorption–spectroscopic Determination of Chromium (Iii) Ions Using Eriochrome Black T Immobilized on Silk Fibroin Fiber
A sorption–spectrophotometric method for the determination of chromium (III) ions was developed using Eriochrome Black T (EBT) immobilized on silk fibroin fiber. Immobilization markedly enhanced the method’s stability, sensitivity, and selectivity. Complex formation was confirmed by FT-IR spectroscopy (Cr–O band at 607 cm⁻¹), X-ray fluorescence analysis (clear Cr peak), and SEM-EDS (≈ 20 wt % Cr in the complex). Optimal conditions were pH 8, λ = 618 nm, and a universal buffer. The detection limit was 1.2 µg L⁻¹; analysis time, 10 min; calibration linearity, R² = 0.9991 for 5–50 µg Cr(III). Average absorbance at 50 µg was 0.273, and Sandell sensitivity 0.00279 µg cm⁻². Selectivity testing showed that Ni²⁺, Fe³⁺, and Cu²⁺ caused no interference, whereas Al³⁺, Co²⁺, and Cd²⁺ interferences were masked effectively. Validation with industrial wastewater (Navoi Electrochemical Plant, Mubarek Gas Processing Plant, Almalyk Mining and Metallurgical Complex) gave relative errors ≤ 6% and Sr ≤ 0.085. The method therefore offers an economical, rapid, and accurate tool for monitoring Cr(III) ions in environmental waters, suitable for both field and laboratory applications.