A Biomechanical Comparison of 2 Techniques of Footprint Reconstruction for Rotator Cuff Repair: The SwiveLock‐FiberChain Construct Versus Standard Double‐Row Repair
- 19 December 2008
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 25 (3) , 274-281
Abstract
Purpose: The purpose of this study was to compare the biomechanical fixation parameters of a standard double‐row rotator cuff repair with those of a knotless footprint reconstruction using the double‐row SwiveLock‐FiberChain technique (Arthrex, Naples, FL). Methods: Seven matched pairs of human cadaveric shoulders were used for testing (mean age, 48 ± 10.3 years). A shoulder from each matched pair was randomly selected to receive a standard 4‐anchor double‐row repair of the supraspinatus tendon, and the contralateral shoulder received a 4‐anchor double‐row SwiveLock‐FiberChain repair. The tendon was cycled from 10 N to 100 N at 1 Hz for 500 cycles, followed by a single‐cycle pull to failure at 33 mm/s. Yield load, ultimate load, cyclic displacement, and mode of failure were recorded. Results: Yield load and ultimate load were higher for the SwiveLock‐FiberChain repair compared with the standard double‐row repair for 6 of the 7 treatment pairs; however, 1 cadaver had a contrary outcome, so the overall mean differences in yield load and ultimate load were not significantly different from 0 by Student t test ( P > .15). Furthermore, smaller differences between yield load and ultimate load for the SwiveLock‐FiberChain repair in 5 of the 7 treatment pairs showed a self‐reinforcing mechanism. Conclusions: Double‐row footprint reconstruction with the knotless SwiveLock‐FiberChain system in this study had yield loads, ultimate loads, and cyclic displacements that were statistically equivalent to those of standard double‐row rotation cuff reconstructions. Clinical Relevance: The SwiveLock‐FiberChain system's combination of strength, self‐reinforcement, and decreased operating time may offer advantages to the surgeon, particularly when dealing with older patients in whom poor tissue quality and total operative time are important considerations.Keywords
Funding Information
- Arthrex
This publication has 24 references indexed in Scilit:
- A Biomechanical Comparison of Single and Double-Row Fixation in Arthroscopic Rotator Cuff RepairJournal of Bone and Joint Surgery, 2006
- The Effect of Double‐Row Fixation on Initial Repair Strength in Rotator Cuff Repair: A Biomechanical StudyArthroscopy, 2006
- Rotator cuff repair: The effect of double-row fixation on three-dimensional repair siteJournal of Shoulder and Elbow Surgery, 2006
- Evaluation of Residual Rotator Cuff Defects After In Vivo Single‐ Versus Double‐Row Rotator Cuff RepairsArthroscopy, 2006
- Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective studyJournal of Shoulder and Elbow Surgery, 2006
- Biomechanical Comparison of a Single-Row versus Double-Row Suture Anchor Technique for Rotator Cuff RepairThe American Journal of Sports Medicine, 2006
- Biomechanical Evaluation of Arthroscopic Rotator Cuff RepairsJournal of Bone and Joint Surgery, 2006
- Open Versus Arthroscopic Rotator Cuff Repair: A Comparative View of 96 CasesArthroscopy, 2005
- The Outcome and Repair Integrity of Completely Arthroscopically Repaired Large and Massive Rotator Cuff TearsJournal of Bone and Joint Surgery, 2004
- Double‐row arthroscopic rotator cuff repair: re‐establishing the footprint of the rotator cuffArthroscopy, 2003