Clinical evaluation of the air-handling properties of contemporary oxygenators with integrated arterial filter
- 20 August 2016
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 32 (2) , 118-125
Abstract
Gaseous microemboli (GME) may originate from the extracorporeal circuit and enter the arterial circulation of the patient. GME are thought to contribute to cerebral deficit and to adverse outcome after cardiac surgery. The arterial filter is a specially designed component for removing both gaseous and solid microemboli. Integration of an arterial filter with an oxygenator is a contemporary concept, reducing both prime volume and foreign surface area. This study aims to determine the air-handling properties of four contemporary oxygenator devices with an integrated arterial filter. Two oxygenator devices, the Capiox FX25 and the Fusion, showed significant increased volume of GME reduction rates (95.03 ± 3.13% and 95.74 ± 2.69%, respectively) compared with both the Quadrox-IF (85.23 ± 5.84%) and the Inspire 6F M (84.41 ± 12.93%). Notably, both the Quadrox-IF and the Inspire 6F M as well as the Capiox FX 25 and the Fusion showed very similar characteristics in volume and number reduction rates and in detailed distribution properties. The Capiox FX25 and the Fusion devices showed significantly increased number and volume reduction rates compared with the Quadrox-IF and the Inspire 6F M devices. Despite the large differences in design of all four devices, our study results suggest that the oxygenator devices can be subdivided into two groups based on their fibre design, which results in screen filter (Quadrox-IF and Inspire 6F M) and depth filter (Capiox FX25 and Fusion) properties. Depth filter properties, as present in the Capiox FX25 and Fusion devices, reduced fractionation of air and may ameliorate GME removal.Keywords
This publication has 25 references indexed in Scilit:
- Use of minimal extracorporeal circulation improves outcome after heart surgery; a systematic review and meta-analysis of randomized controlled trialsInternational Journal of Cardiology, 2013
- Impact of the intensity of microemboli on neurocognitive outcome following cardiopulmonary bypassPerfusion, 2013
- Clinical Evaluation of the Air Removal Characteristics of an Oxygenator with Integrated Arterial Filter in a Minimized Extracorporeal CircuitThe International Journal of Artificial Organs, 2011
- Air Removal Efficiency of a Venous Bubble Trap in a Minimal Extracorporeal Circuit During Coronary Artery Bypass GraftingArtificial Organs, 2010
- Extracorporeal bubbles: a word of cautionInteractive CardioVascular and Thoracic Surgery, 2010
- Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trialEuropean Heart Journal, 2009
- Meta-analysis of randomised trials comparing the effectiveness of miniaturised versus conventional cardiopulmonary bypass in adult cardiac surgeryHeart, 2009
- Microemboli detection on extracorporeal bypass circuitsaPerfusion, 2008
- Gaseous Microemboli Sizing in Extracorporeal Circuits Using Ultrasound BackscatterUltrasound in Medicine & Biology, 2007
- Adverse effects of low hematocrit during cardiopulmonary bypass in the adult: should current practice be changed?The Journal of Thoracic and Cardiovascular Surgery, 2003